Direct multi-element analysis of biological samples in dry matrix spots by PIXE

被引:1
|
作者
Krmpotic, Matea [1 ]
Telkhozhayeva, Madina [2 ]
Tsubery, Merav Nadav [3 ]
Goldenberg-Cohen, Nitza [4 ]
Girshevitz, Olga [2 ]
机构
[1] Rudjer Boskovic Inst, Div Expt Phys, Zagreb 10000, Croatia
[2] Bar Ilan Univ, Bar Ilan Inst Nanotechnol & Adv Mat, IL-5290002 Ramat Gan, Israel
[3] Bar Ilan Univ, Dept Chem, IL-5290002 Ramat Gan, Israel
[4] Technion Israel Inst Technol, Rappaport Fac Med, Krieger Eye Res Lab, Haifa, Israel
关键词
Dried matrix spots; PIXE; Blood; Serum; Plasma; DRIED BLOOD SPOTS; DROPLET LASER-ABLATION; FILTER-PAPER; MULTIPLE ELEMENTS; QUANTIFICATION; SPECTROMETRY; LEAD; MS;
D O I
10.1016/j.talanta.2024.127394
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The dried matrix spot (DMS) method, initially developed for neonatal blood screening, has gained prevalence in various research fields for its efficiency in handling small sample volumes and its adaptability to diverse analytical techniques. This study presents the results of the first systematic investigation of direct multi-element analysis in DMS of human blood and plasma samples with Particle Induced X-ray Emission (PIXE). Internal standard addition was used to address the issue of DMS heterogeneity and to eliminate the need for determining the sample volume equivalent, allowing a single-spot (single-punch) measurement. The method was tested for linearity, accuracy, precision and limit of detection (LOD) using reference materials. It was applied to samples from healthy volunteers and compared to analysis results obtained by ICP-OES showing good agreement. Sample volumes as low as 50 mu L were sufficient for the quantification of Na, Mg, P, S, K, Ca, Fe, and Zn in whole blood, and Na, Mg, P, S, K, and Ca in plasma samples without significant matrix effects being observed. Chlorine, which is also an electrolyte element present in high enough concentrations for determination by PIXE, was not addressed in this study due to a lack of reference materials. The results highlight PIXE as a viable alternative to other techniques that are sensitive to matrix issues, require larger sample volumes and/or sample treatment. Overall, this work establishes DMS sampling as being suitable for direct multi-element analysis of biological samples by PIXE, offering detection limits at the mg/L level which is sufficient for determination of electrolyte and essential trace elements and paving the way for its broader application in clinical and research settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Multi-element analysis of dry-ashed honey samples by thick-target PIXE
    Saarela, KE
    Lill, JO
    Harju, L
    Lindroos, A
    Heselius, SJ
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1998, 69 (04) : 273 - 285
  • [2] MULTI-ELEMENT ANALYSIS OF SMALL BIOLOGICAL SAMPLES
    ROKITA, E
    MAENHAUT, W
    CAFMEYER, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (02) : 1601 - 1603
  • [3] TRACE PRECONCENTRATION FOR PIXE MULTI-ELEMENT ANALYSIS
    BRUGGERHOFF, S
    JACKWERTH, E
    SALEWSKI, S
    RAITH, B
    DIVOUX, S
    GONSIOR, B
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (9-11) : 1181 - 1188
  • [4] DIRECT MULTI-ELEMENT ANALYSIS OF SELF-SUPPORTING TARGETS OF SOME BIOLOGICAL STANDARD REFERENCE MATERIALS AND OTHERS BY PIXE
    NAVARRETE, VR
    IZAWA, G
    SHIOKAWA, T
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1978, 17 : 422 - 424
  • [5] Multi-element analysis of microalgae using Bio-PIXE
    Obata, T
    Sera, K
    Futatsugawa, S
    Shiraiwa, Y
    PLANT AND CELL PHYSIOLOGY, 2005, 46 : S20 - S20
  • [6] THE NONDESTRUCTIVE TRACE MULTI-ELEMENT ANALYSIS IN GELATIN REFERENCE MATERIALS BY PIXE
    NAVARRETE, VR
    IZAWA, G
    SHIOKAWA, T
    KAMIYA, M
    MORITA, S
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1980, 44 (05): : 287 - 296
  • [7] IDENTIFICATION OF SAMPLES AND INDIVIDUALS BY MULTI-ELEMENT ACTIVATION ANALYSIS
    COLEMAN, RF
    GOODE, GC
    WOOD, GA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (02): : 507 - &
  • [8] THE VALIDATION OF A PIXE SYSTEM FOR TRACE-ELEMENT ANALYSIS OF BIOLOGICAL SAMPLES
    SAIED, SO
    CRUMPTON, D
    FRANCOIS, PE
    NUCLEAR INSTRUMENTS & METHODS, 1981, 181 (1-3): : 53 - 57
  • [9] Energy dispersive X-ray fluorescence spectrometry for the direct multi-element analysis of dried blood spots
    Margui, E.
    Queralt, I.
    Garcia-Ruiz, E.
    Garcia-Gonzalez, E.
    Rello, L.
    Resano, M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 139 : 13 - 19
  • [10] Advantages of synthetic multi-element reference material with pseudo-biological matrix in activation analysis
    Y. Iwata
    N. Suzuki
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 233 : 49 - 53