FREQUENCY DOMAIN METHOD FOR DYNAMIC RESPONSES OF TRANSMISSION TOWER UNDER DOWNBURST

被引:0
|
作者
Wang, Da-Hai [1 ]
Wang, Guo-Qiang [1 ,2 ]
Wang, Xin [3 ]
Sun, Qi-Gang [4 ]
Yang, Qing-Shan [5 ]
Huang, Guo-Qing [5 ]
Yang, Jun-Yong [6 ]
机构
[1] School of Civil Engineering and Architecture, Wuhan University of Technology, Wuhan,430070, China
[2] Wuhan Engineering Construction Law Enforcement Inspection Station, Wuhan,430024, China
[3] Tongyuan Design Group Co., Ltd., Jinan,250101, China
[4] State Grid Shandong Electric Power Company, Institution of Economy and Technology, Jinan,250000, China
[5] School of Civil Engineering, Chongqing University, Chongqing,400045, China
[6] State Grid Shandong Electric Power Company, Laiwu Power Supply Company, Jinan,250000, China
来源
Gongcheng Lixue/Engineering Mechanics | 2024年 / 41卷 / 08期
关键词
Aerodynamic loads - Convergence of numerical methods - Electric towers - Foundations - Fracture mechanics - Health risks - Hydraulic structures - Pressure vessels - Vibration analysis - Wind stress;
D O I
10.6052/j.issn.1000-4750.2022.06.0580
中图分类号
学科分类号
摘要
Localized severe wind such as downbursts is responsible for structural failures of transmission lines because it is always characterized by small size, high intensity and sudden change. The purpose of the study is to search a theoretical analysis framework for investigation of the dynamic response of transmission towers under downburst attack in frequency domains. To begin, using the theoretical model for time-varying mean wind and for non-stationary fluctuating wind, the expressions of impacting wind load on a transmission tower by the moving downburst in time and frequency domain are developed respectively. Upon the random vibration theory, the frequency domain solution of non-stationary fluctuating wind-induced response of transmission towers is proposed. Subsequently, through the extreme value theory of first-passage, the extreme value probability distribution of dynamic response under the non-stationary downburst wind load was proposed in theoretical approach, as well as the simplified solution for peak factor by equivalent stationary extreme value distribution are supplied. The accuracy of the frequency-domain theoretical method was verified using the finite element transient dynamic analysis results of random samples. This study indicated that the multi-source non-stationary excitation at different heights of the tower can be simplified to synchronous slow-varying excitation. The theoretical solution of non-stationary response extremum distribution has high accuracy, and the peak factor by equivalent stationary extreme value distribution is convenient and slightly conservative. The study provides a theoretical basis and technique for the improvement of thunderstorm-resistant design of transmission towers. © 2024 Tsinghua University. All rights reserved.
引用
收藏
页码:152 / 163
相关论文
共 50 条
  • [41] A Method for Settlement Detection of the Transmission Line Tower under Wind Force
    Huang, Xinbo
    Zhao, Yu
    Zhao, Long
    Yang, Luya
    SENSORS, 2018, 18 (12)
  • [42] A study on identification of dynamic characteristic parameters of a transmission tower under ambient excitations
    Zhao C.
    Zhao J.
    Sun Q.
    Yuan J.
    Wang H.
    He Y.
    Tan R.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2021, 40 (04): : 30 - 35
  • [43] Identification of the dynamic properties of a transmission line lattice tower under ambient excitations
    Yang, Fengli
    Zhang, Hongjie
    Yang, Jingbo
    Hua, Xugang
    Wen, Qing
    Niu, Huawei
    Zhendong yu Chongji/Journal of Vibration and Shock, 2017, 36 (21): : 144 - 149
  • [44] Failure mechanism and invalidation principle of a super-large cooling tower under downburst
    Ke S.-T.
    Li W.-J.
    Han G.-Q.
    Yang J.
    Ren H.-H.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2022, 35 (05): : 1037 - 1047
  • [45] / Dynamic Characteristic Analysis of Transmission Tower
    Xie, Xiangzan
    Wei, Kelun
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 1719 - +
  • [46] IRI Estimation by the Frequency Domain Analysis of Vehicle Dynamic Responses
    Zhao, Boyu
    Nagayama, Tomonori
    STRUCTURAL HEALTH MONITORING - FROM SENSING TO DIAGNOSIS AND PROGNOSIS, 2017, 188 : 9 - 16
  • [47] Operational modal analysis of Canton Tower by a fast frequency domain Bayesian method
    Zhang, Feng-Liang
    Ni, Yi-Qing
    Ni, Yan-Chun
    Wang, You-Wu
    SMART STRUCTURES AND SYSTEMS, 2016, 17 (02) : 209 - 230
  • [48] Behaviour of guyed transmission line structures under downburst wind loading
    Shehata, A. Y.
    El Damatty, A. A.
    WIND AND STRUCTURES, 2007, 10 (03) : 249 - 268
  • [49] Two case studies on structural analysis of transmission towers under downburst
    Yang, FengLi
    Zhang, HongJie
    WIND AND STRUCTURES, 2016, 22 (06) : 685 - 701
  • [50] A frequency domain analysis method for the dynamic response of a submerged floating tunnel under wave action
    Yu, Mei
    Cong, Longfei
    Teng, Bin
    OCEAN ENGINEERING, 2024, 312