Experimental study on enhancing the performance of hydrokinetic integrated Darrieus-Savonius rotor in open water-channel

被引:0
作者
Nasef, M. H. [1 ]
El-Askary, W. A. [2 ,4 ]
Ashmawy, Ahmed [3 ]
Abd Elhamid, Ahmed M. I. [3 ]
机构
[1] Fayoum Univ, Fac Engn, Mech Eng Dept, Al Fayyum 63514, Egypt
[2] Menoufia Univ, Fac Engn, Dept Mech Power Engn, Shebin Al Kom 32511, Egypt
[3] Hydraul Res Inst HRI, Natl Water Res Ctr NWRC, El Qanater El Khiriaya 13621, Egypt
[4] Alexandria Higher Inst Engn Technol AIET, Alexandria, Egypt
关键词
Hydrokinetic rotor; Radius ratio; Add-on angle; Power-factor; AXIS WIND TURBINE; ATTACHMENT ANGLE; RADIUS RATIO; ENERGY; DESIGN; CFD; EXTRACTION; FLOW;
D O I
10.1016/j.renene.2024.121443
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The kinetic energy stored in water streams could be used to generate electricity via hydrokinetic rotors, due to the availability of kinetic energy from flowing water. Darrieus and Savonius are vertical axis kinetic rotors, they are promising for generating power in low speed flows. The integrated Darrieus- Savonius hydrokinetic rotor works on the principles of integrated forces including lift and drag forces. An experimental investigation has been conducted to get the optimum configuration for Darrieus-Savonius integrated rotor in order to attain improved self-starting and high-power-factor in open channel water flow, under different inflow conditions. This study investigated the effects of the radius ratio, add-on angle, water heights, and flow velocity on performance of hydrokinetic integrated Darrieus-Savonius rotor with three standard NACA 020 airfoil shape as Darrieus rotor and single/double stage semi-circular blades as Savonius rotor on the power factor. Three radius ratios (R.R) namely (0.8, 0.6 and 0.4) and add-on angles of (0(o), 30(o), 45(o), 60(o) and 90(o)) were studied. The experimental channel was (26 m) long water flume with a (1m wide x1.2 m depth). The horizontal walls of the flume were made of glass with a strengthened frame, to permit visual examination. The flume entrance consisted of a receiving tank (3 m long, 1.5 m wide, and 0.75 m depth), a honeycomb pattern pipe box, and a screen box field with a large stone to dissipate the water turbulence and energy at the entrance. Two centrifugal pumps were used to supply water to the channel. Darrieus-Savonius integrated rotor was placed at distance equal to ten times width of the experimental channel, to avoid any turbulence and to make sure that the flow was steady. Based on the experimental results, it was observed that the optimum Cp values at lambda (1.84), add-on angle of (45(o)) and R.R (0.4, 0.6 and 0.8) were (0.335, 0.29 and 0.299) respectively. The maximum hybrid performance was attained at R.R (0.4), add-on angle (45(o)) and tip-speed ratio (1.8) and Re (240x106) with value of (0.339). Decrease in the Re values by 25 % enhanced the performance by 1.19 %. Accordingly, it is not necessary to rely on Re values in calculating the power-factor values compared to the influence of the rest of the variables.
引用
收藏
页数:11
相关论文
共 38 条
  • [1] Performance assessment of a modified of Savonius rotor: Impact of sine and conical blade profiles
    Abdelaziz, Khaled R.
    Nawar, Mohamed A. A.
    Ramadan, Ahmed
    Attai, Youssef A.
    Mohamed, Mohamed H.
    [J]. ENERGY, 2023, 272
  • [2] Performance study on a modified hybrid wind turbine with twisted Savonius blades
    Abdelsalam, Ali M.
    Kotb, M. A.
    Yousef, Khaled
    Sakr, I. M.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 241
  • [3] Discussion on the verification of the overlap ratio influence on performance coefficients of a Savonius wind rotor using computational fluid dynamics
    Akwa, Joao Vicente
    da Silva Junior, Gilmar Alves
    Petry, Adriane Prisco
    [J]. RENEWABLE ENERGY, 2012, 38 (01) : 141 - 149
  • [4] Effects of internal rotor parameters on the performance of a two bladed Darrieus-two bladed Savonius hybrid wind turbine
    Asadi, Mohammad
    Hassanzadeh, Rahim
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 238
  • [5] Investigations on self-starting and performance characteristics of simple H and hybrid H-Savonius vertical axis wind rotors
    Bhuyan, S.
    Biswas, A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 87 : 859 - 867
  • [6] The effect of the opening ratio and location on the performance of a novel vertical axis Darrieus turbine
    Chen, Jian
    Yang, Hongxing
    Yang, Mo
    Xu, Hongtao
    [J]. ENERGY, 2015, 89 : 819 - 834
  • [7] Numerical investigation of a novel contra-rotating vertical axis wind turbine
    Didane, Djamal Hissein
    Rosly, Nurhayati
    Zulkafli, Mohd Fadhli
    Shamsudin, Syariful Syafiq
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2019, 31 : 43 - 53
  • [8] CFD and PIV investigation of unsteady flow through Savonius wind turbine
    Dobrev, Ivan
    Massouh, Fawaz
    [J]. IMPACT OF INTEGRATED CLEAN ENERGY ON THE FUTURE OF THE MEDITERRANEAN ENVIRONMENT, 2011, 6 : 711 - 720
  • [9] Investigating the performance of a twisted modified Savonius rotor
    El-Askary, W. A.
    Saad, Ahmed S.
    AbdelSalam, Ali M.
    Sakr, I. M.
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2018, 182 : 344 - 355
  • [10] Harvesting wind energy for improving performance of Savonius rotor
    El-Askary, W. A.
    Nasef, M. H.
    AbdEL-hamid, A. A.
    Gad, H. E.
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2015, 139 : 8 - 15