Optimizing cascade refrigeration systems with low GWP refrigerants for Low-Temperature Applications: A thermodynamic analysis

被引:4
作者
Arefin, Md. Miraj [1 ]
Mondal, Dipayan [1 ]
Islam, Md. Ashraful [1 ]
机构
[1] Khulna Univ Engn & Technol, Dept Mech Engn, Khulna 9203, Bangladesh
关键词
Cascade refrigeration system; Low GWP refrigerants; Exergy analysis; COP; Thermodynamic comparison; MULTIOBJECTIVE OPTIMIZATION; EXERGY ANALYSIS; CIS-1,1,1,4,4,4-HEXAFLUORO-2-BUTENE R-1336MZZ(Z); PERFORMANCE EVALUATION; VAPOR-PRESSURE; 3E ANALYSES; ENERGY; AMMONIA; LIQUID; R1234YF;
D O I
10.1016/j.ecmx.2024.100722
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study offers a comprehensive thermodynamic analysis of a cascade refrigeration system conducted for low-temperature applications, focusing on the use of low-GWP and zero-ODP refrigerants to improve efficiency and sustainability. The target of this study is to explore the performance of the system using a combination of refrigerants: low-temperature cycle refrigerants such as R744, while high-temperature cycle refrigerants such as R717, R1234yf, R1234ze(E), R1336mzz(E), and R1336mzz(Z), respectively. The ECS model incorporating in REFPROP 10.0a tool was utilized to extract the data through coding for analysis. The assessment of this system involves the examination of various parameters such as its coefficient of performance, total compressor workload, total exergy, and exergy efficiency across various operational conditions. The results are compared with and without superheated and subcooled conditions to understand the impact of these parameters on the system performance. The system with R744 in the low-temperature cycle and R717, R1234yf, R1234ze(E), R1336mzz(E), and R1336mzz(Z) in the high-temperature cycle provides a higher COP and lower total compressor work compared to the conventional cascade refrigeration system. In optimal CRS, the R744-R717 pair attains the highest COP of 2.05 at the lowest possible compressor work from 9.53 to 4.87 kW than other refrigerants pair while evaporator temperature shifting from -55 degrees C to -20 degrees C. The exergy efficiency of R744/R717 is found at 26.47 % at an evaporator temperature of -55 degrees C, but it extends to a peak of 51.73 % at -20 degrees C. The study also shows that the superheating and sub-cooling of the refrigerants have a significant impact on the performance of the cascade refrigeration system. Superheating and sub-cooling at 10 degrees C, improves the COP of the system by reducing the compressor work and increasing the heat transfer efficiency. The research offers valuable insights into the system's thermodynamic performance when employing low GWP refrigerants in low-temperature applications. These findings have the potential to guide the design and optimization of cascade refrigeration systems over the range of low-temperature applications.
引用
收藏
页数:18
相关论文
共 102 条
[1]   Comparative thermodynamic performance analysis of a cascade refrigeration system with new refrigerants paired with CO2 [J].
Adebayo, Victor ;
Abid, Muhammad ;
Adedeji, Michael ;
Dagbasi, Mustafa ;
Bamisile, Olusola .
APPLIED THERMAL ENGINEERING, 2021, 184
[2]  
Akasaka R., 2016, P 8 AS C REG AIR CON
[3]  
Akasaka R., 2022, PROCC 19 INT REFR AI, P2170
[4]   A Helmholtz Energy Equation of State for trans-1,1,1,4,4,4-Hexafluoro-2-butene [R-1336mzz(E)] and an Auxiliary Extended Corresponding States Model for the Transport Properties [J].
Akasaka, Ryo ;
Huber, Marcia L. ;
Simoni, Luke D. ;
Lemmon, Eric W. .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2023, 44 (04)
[5]   Comparative energy and exergy analysis of a subcritical cascade refrigeration system using low global warming potential refrigerants [J].
Aktemur, Cenker ;
Ozturk, Ilhan Tekin ;
Cimsit, Canan .
APPLIED THERMAL ENGINEERING, 2021, 184
[6]   Measurement of Viscosity of cis-1,1,1,4,4,4-Hexafluoro-2-butene (R-1336mzz(Z)) by Tandem Capillary Tubes Method [J].
Alam, Md Jahangir ;
Miyara, Akio ;
Kariya, Keishi ;
Kontomaris, Konstantinos Kostas .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2018, 63 (05) :1706-1712
[7]   Measurement of thermal conductivity of cis-1,1,1,4,4,4-hexafluoro-2-butene (R-1336mzz(Z)) by the transient hot-wire method [J].
Alam, Md Jahangir ;
Islam, Mohammad Ariful ;
Kariya, Keishi ;
Miyara, Akio .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 :220-227
[8]   Experimental evaluation of a cascade refrigeration system prototype with CO2 and NH3 for freezing process applications [J].
Alberto Dopazo, J. ;
Fernandez-Seara, Jose .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01) :257-267
[9]   Exergetic, economic and environmental (3E) analyses, and multiobjective optimization of a CO2/NH3 cascade refrigeration system [J].
Aminyavari, Mehdi ;
Najafi, Behzad ;
Shirazi, Alec ;
Rinaldi, Fabio .
APPLIED THERMAL ENGINEERING, 2014, 65 (1-2) :42-50
[10]   Thermodynamic analysis of auto-cascade refrigeration cycles, with and without ejector, for ultra low temperature freezing using a mixture of refrigerants R600a and R1150 [J].
Angel Rodriguez-Jara, Enrique ;
Jose Sanchez-de-la-Flor, Francisco ;
Antonio Exposito-Carrillo, Jose ;
Manuel Salmeron-Lissen, Jose .
APPLIED THERMAL ENGINEERING, 2022, 200