Integrated Real-Time CMOS Luminescence Sensing and Impedance Spectroscopy in Droplet Microfluidics

被引:0
作者
Liu, Qijun [1 ]
Mendoza, Diana Arguijo [2 ]
Yasar, Alperen [1 ]
Caygara, Dilara [1 ]
Kassem, Aya [1 ]
Densmore, Douglas [2 ,3 ]
Yazicigil, Rabia Tugce [2 ,3 ]
机构
[1] Boston Univ, Dept Elect & Comp Engn, Boston, MA 02215 USA
[2] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[3] Boston Univ, Dept Elect & Comp Engn, Boston, MA 02215 USA
关键词
Microfluidics; Biosensors; Sensors; Impedance; Luminescence; Electrodes; Spectroscopy; Circuits and systems; Throughput; Substrates; Impedance spectroscopy; bioluminescence detector; droplet microfluidics; synthetic biology; biosensors; SILICON PHOTOMULTIPLIERS; PAD BIOSENSOR; DIGITAL SIPM; LARGE-AREA; CAPABILITIES; DEVICES; ARRAY; CHIP; PMMA;
D O I
10.1109/TBCAS.2024.3491594
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High-throughput biosensor screening and optimization are critical for health and environmental monitoring applications to ensure rapid and accurate detection of biological and chemical targets. Traditional biosensor design and optimization methods involve labor-intensive processes, such as manual pipetting of large sample volumes, making them low throughput and inefficient for large-scale library screenings under various environmental and chemical conditions. We address these challenges by introducing a modular droplet microfluidic system embedded with custom CMOS integrated circuits (ICs) for impedance spectroscopy and bioluminescence detection. Fabricated in a 65 nm process, our CMOS ICs enable efficient droplet detection and analysis. We demonstrate successful sensing of luciferase enzyme-substrate reactions in nL-volume droplets. The impedance spectroscopy chip detects 4 nL droplets at 67 mm/s with a 45 pA resolution, while the luminescence detector senses optical signals from 38 nL droplets with a 6.7 nA/count resolution. We show real-time concurrent use of both detection methods within our hybrid platform for cross-validation. This system greatly advances conventional biosensor testing by increasing flexibility, scalability, and cost-efficiency.
引用
收藏
页码:1233 / 1252
页数:20
相关论文
共 50 条
  • [41] Real-Time Bioimpedance Sensing of Antifibrotic Drug Action in Primary Human Cells
    Parviz, Maryam
    Toshniwal, Priyanka
    Viola, Helena M.
    Hool, Livia C.
    Fear, P. Mark W.
    Wood, Fiona M.
    Gaus, Katharina
    Iyer, K. Swaminathan
    Gooding, J. Justin
    [J]. ACS SENSORS, 2017, 2 (10): : 1482 - 1490
  • [42] Synthesis and Characterization of Indium-Doped SnO2-Based Impedance Spectroscopy Sensor for Real-Time Humidity Sensing Applications
    Alemayehu, Birhanu
    Shin, Eunsung
    Vasilyev, Vladimir
    Subramanyam, Guru
    [J]. CRYSTALS, 2024, 14 (01)
  • [43] Intervention of cardiomyocyte death based on real-time monitoring of cell adhesion through impedance sensing
    Qiu, Yiling
    Liao, Ronglih
    Zhang, Xin
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 25 (01) : 147 - 153
  • [44] Real-time, label-free monitoring of the cell cycle with a cellular impedance sensing chip
    Wang, Lei
    Wang, Lei
    Yin, Hongying
    Xing, Wanli
    Yu, Zhongyao
    Guo, Min
    Cheng, Jing
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 25 (05) : 990 - 995
  • [45] Ultrasensitive Molecular Sensors Based on Real-Time Impedance Spectroscopy in Solution-Processed 2D Materials
    Moore, David C.
    Jawaid, Ali
    Busch, Robert
    Brothers, Michael
    Miesle, Paige
    Miesle, Adam
    Rao, Rahul
    Lee, Jonghoon
    Beagle, Lucas K.
    Motala, Michael
    Wallace, Shay Goff
    Downing, Julia R.
    Roy, Ajit
    Muratore, Christopher
    Hersam, Mark C.
    Vaia, Richard
    Kim, Steve
    Glavin, Nicholas R.
    [J]. ADVANCED FUNCTIONAL MATERIALS, 2022, 32 (12)
  • [46] Multilayered Fabric Pressure Sensor for Real-Time Piezo-Impedance Imaging of Pressure Distribution
    Jeong, You Jeong
    Kim, Young Eun
    Kim, Kap Jin
    Woo, Eung Je
    Oh, Tong In
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (02) : 565 - 572
  • [47] Real-time imaging of microparticles and living cells with CMOS nanocapacitor arrays
    Laborde, C.
    Pittino, F.
    Verhoeven, H. A.
    Lemay, S. G.
    Selmi, L.
    Jongsma, M. A.
    Widdershoven, F. P.
    [J]. NATURE NANOTECHNOLOGY, 2015, 10 (09) : 791 - +
  • [48] Real-time monitoring of immobilized single yeast cells through multifrequency electrical impedance spectroscopy
    Zhu, Zhen
    Frey, Olivier
    Franke, Felix
    Haandbaek, Niels
    Hierlemann, Andreas
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (27) : 7015 - 7025
  • [49] Real-time monitoring of immobilized single yeast cells through multifrequency electrical impedance spectroscopy
    Zhen Zhu
    Olivier Frey
    Felix Franke
    Niels Haandbæk
    Andreas Hierlemann
    [J]. Analytical and Bioanalytical Chemistry, 2014, 406 : 7015 - 7025
  • [50] Biodegradable Implant Antenna Utilized for Real-Time Sensing through Genetically Modified Bacteria
    Bilir, Ahmet
    Dumanli, Sema
    [J]. 2024 18TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2024,