First clinical implementation of a highly efficient daily online adapted proton therapy (DAPT) workflow

被引:3
作者
Albertini, F. [1 ]
Czerska, K. [1 ]
Vazquez, M. [1 ]
Andaca, I [1 ]
Bachtiary, B. [1 ]
Besson, R. [1 ]
Bolsi, A. [1 ]
Bogaert, A. [1 ]
Choulilitsa, E. [1 ,2 ]
Hrbacek, J. [1 ]
Jakobsen, S. [1 ]
Leiser, D. [1 ]
Matter, M. [1 ]
Mayor, A. [1 ]
Meier, G. [1 ]
Nanz, A. [1 ]
Nenoff, L. [1 ]
Oxley, D. [1 ]
Siewert, D. [1 ]
Schnidrig, B. A. Rohrer [1 ]
Smolders, A. [1 ,2 ]
Szweda, H. [1 ]
Van Heerden, M. [1 ]
Winterhalter, C. [1 ]
Lomax, A. J. [1 ,2 ]
Weber, D. C. [1 ,3 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Univ Hosp Bern, Dept Radiat Oncol, Bern, Switzerland
基金
瑞士国家科学基金会; 欧盟地平线“2020”;
关键词
DAPT; daily adaptive proton therapy; online adaptive proton therapy; adaptive proton therapy; COMPREHENSIVE ANALYSIS; ROBUST OPTIMIZATION; RANGE UNCERTAINTIES; RADIATION-THERAPY; LOG FILES; RADIOTHERAPY; HEAD; SENSITIVITY; FRACTION; QUALITY;
D O I
10.1088/1361-6560/ad7cbd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. This study presents the first clinical implementation of an efficient online daily adaptive proton therapy workflow (DAPT). Approach. The DAPT workflow includes a pre-treatment phase, where a template and a fallback plan are optimized on the planning computed tomography (CT). In the online phase, the adapted plan is re-optimized on daily images from an in-room CT. Daily structures are rigidly propagated from the planning CT. Automated Quality Assurance (QA) involves geometric, sanity checks and an independent dose calculation from the machine files. Differences from the template plan are analyzed field-by-field, and clinical plan is assessed by reviewing the achieved clinical goals using a traffic light protocol. If the daily adapted plan fails any QA or clinical goals, the fallback plan is used. In the offline phase the delivered dose is recalculated from log-files onto the daily CT, and a gamma analysis is performed (3%/3 mm). The DAPT workflow has been applied to selected adult patients treated in rigid anatomy for the last serie of the treatment between October 2023 and April 2024. Main Results. DAPT treatment sessions averaged around 23 min [range: 15-30 min] and did not exceed the typical 30 minute time slot. Treatment adaptation, including QA and clinical plan assessment, averaged just under 7 min [range: 3:30-16 min] per fraction. All plans passed the online QAs steps. In the offline phase a good agreement with the log-files reconstructed dose was achieved (minimum gamma pass rate of 97.5%). The online adapted plan was delivered for > 85% of the fractions. In 92% of total fractions, adapted plans exhibited improved individual dose metrics to the targets and/or organs at risk. Significance. This study demonstrates the successful implementation of an online daily DAPT workflow. Notably, the duration of a DAPT session did not exceed the time slot typically allocated for non-DAPT treatment. As far as we are aware, this is a first clinical implementation of daily online adaptive proton therapy.
引用
收藏
页数:17
相关论文
共 62 条
[1]   Online Magnetic Resonance Image Guided Adaptive Radiation Therapy: First Clinical Applications [J].
Acharya, Sahaja ;
Fischer-Valuck, Benjamin W. ;
Kashani, Rojano ;
Parikh, Parag ;
Yang, Deshan ;
Zhao, Tianyu ;
Green, Olga ;
Wooten, Omar ;
Li, H. Harold ;
Hu, Yanle ;
Rodriguez, Vivian ;
Olsen, Lindsey ;
Robinson, Clifford ;
Michalski, Jeff ;
Mutic, Sasa ;
Olsen, Jeffrey .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (02) :394-403
[2]  
Albertini F, 2015, RADIOTHER ONCOL, V115, pS536
[3]   Online daily adaptive proton therapy [J].
Albertini, Francesca ;
Matter, Michael ;
Nenoff, Lena ;
Zhang, Ye ;
Lomax, Antony .
BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1107)
[4]   An approach for estimating dosimetric uncertainties in deformable dose accumulation in pencil beam scanning proton therapy for lung cancer [J].
Amstutz, Florian ;
Nenoff, Lena ;
Albertini, Francesca ;
Ribeiro, Cassia O. ;
Knopf, Antje C. ;
Unkelbach, Jan ;
Weber, Damien C. ;
Lomax, Antony J. ;
Zhang, Ye .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (10)
[5]   Treatment log files as a tool to identify treatment plan sensitivity to inaccuracies in scanned proton beam delivery [J].
Belosi, Maria Francesca ;
van der Meer, Robert ;
de Acilu Laa, Paz Garcia ;
Bolsi, Alessandra ;
Weber, Damien C. ;
Lomax, Antony J. .
RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) :514-519
[6]   XFeasibility of online IMPT adaptation using fast, automatic and robust dose restoration [J].
Bernatowicz, Kinga ;
Geets, Xavier ;
Barragan, Ana ;
Janssens, Guillaume ;
Souris, Kevin ;
Sterpin, Edmond .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (08)
[7]   Large anatomical changes in head-and-neck cancers-A dosimetric comparison of online and offline adaptive proton therapy [J].
Bobic, Mislav ;
Lalonde, Arthur ;
Nesteruk, Konrad P. ;
Lee, Hoyeon ;
Nenoff, Lena ;
Gorissen, Bram L. ;
Bertolet, Alejandro ;
Busse, Paul M. ;
Chan, Annie W. ;
Winey, Brian A. ;
Sharp, Gregory C. ;
Verburg, Joost M. ;
Lomax, Antony J. ;
Paganetti, Harald .
CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2023, 40
[8]   Evaluation of the clinical value of automatic online dose restoration for adaptive proton therapy of head and neck cancer [J].
Borderias-Villarroel, Elena ;
Taasti, Vicki ;
Van Elmpt, Wouter ;
Teruel-Rivas, S. ;
Geets, X. ;
Sterpin, E. .
RADIOTHERAPY AND ONCOLOGY, 2022, 170 :190-197
[9]   The biologic relevance of daily dose variations in adaptive treatment planning [J].
Bortfeld, Thomas ;
Paganetti, Harald .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (03) :899-906
[10]   Varian ethos online adaptive radiotherapy for prostate cancer: Early results of contouring accuracy, treatment plan quality, and treatment time [J].
Byrne, Mikel ;
Archibald-Heeren, Ben ;
Hu, Yunfei ;
Teh, Amy ;
Beserminji, Rhea ;
Cai, Emma ;
Liu, Guilin ;
Yates, Angela ;
Rijken, James ;
Collett, Nick ;
Aland, Trent .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (01)