A high-resolution 3D radiochromic hydrogel photonic crystal dosimeter for clinical radiotherapy

被引:0
|
作者
Wang, Zhihao [1 ]
Chen, Xianmei [1 ]
Wang, Tingting [2 ]
Tang, Mingshuo [1 ]
He, Zhiwei [1 ]
Wang, Yunlong [1 ]
Ma, Jun [1 ,3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mat Sci & Technol, Nanjing 211106, Peoples R China
[2] Univ Elect Sci & Technol China, Mianyang Cent Hosp, Sch Med, NHC Key Lab Nucl Technol Med Transformat, Mianyang 621000, Peoples R China
[3] Univ Sci & Technol China, Sch Nucl Sci & Technol, Hefei 230026, Anhui, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
ION-CHAMBER; GEL; FILM; QUALITY; ACETYLATION; DIFFUSION; ACCURACY; DETECTOR; ERROR;
D O I
10.1039/d4mh01235f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The precise, rapid and direct visualization of 3D topographical dose in the target tissue that is crucial for effective radiation therapy remains a challenge. Herein, by combining hydrogel photonic crystals with film stacking or 3D printing, a 3D radiochromic dosimeter with a dose sensitivity of up to 10 nm Gy(-1), a spatial resolution <50 mu m, and the ability to detect complex 3D topographical dose distribution was proposed for clinical radiation dose verification. The sensitivity and response range of the dosimeter by radiation-induced polymer cross-linking and consequent Bragg wavelength shift can be tuned via the solid content and extent of acrylate modification. The combination of rapid readout, low dose response, high spatial resolution, and great pre-irradiation and post-irradiation stability highlights the translational potential of this technology for topographical dose mapping in clinical radiotherapy applications.
引用
收藏
页码:1234 / 1245
页数:12
相关论文
共 50 条
  • [41] Reconstruction of high resolution MLC leaf positions using a low resolution detector for accurate 3D dose reconstruction in IMRT
    Visser, R.
    Godart, J.
    Wauben, D. J. L.
    Langendijk, J. A.
    van't Veld, A. A.
    Korevaar, E. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23) : N642 - N649
  • [42] The relationships between 2D and 3D green index altered by spatial attributes at high spatial resolution
    Bai, Zhuhui
    Wang, Zhifang
    Li, Dan
    Wang, Xiaomeng
    Jian, Yuqing
    URBAN FORESTRY & URBAN GREENING, 2024, 101
  • [43] Clinical evaluation of 3D high-resolution isotropic knee MRI using Multi-Interleaved X-prepared TSE with inTUitive RElaxometry (MIXTURE) for simultaneous morphology and T2 mapping
    Sakai, Takayuki
    Yoneyama, Masami
    Zhang, Shuo
    Kitsukawa, Kaoru
    Yokota, Hajime
    Ichikawa, Rina
    Aoki, Yasuchika
    Watanabe, Atsuya
    Sato, Yusuke
    Yanagawa, Noriyuki
    Murayama, Daichi
    Ito, Hajime
    Ochi, Shigehiro
    Miyati, Tosiaki
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 177
  • [44] Articular cartilage grading of the knee: diagnostic performance of fat-suppressed 3D volume isotropic turbo spin-echo acquisition (VISTA) compared with 3D T1 high-resolution isovolumetric examination (THRIVE)
    Lee, Young Han
    Hahn, Seok
    Lim, Daekeon
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2017, 58 (02) : 190 - 196
  • [45] Development of a 2D Image Reconstruction and Viewing System for Histological Images from Multiple Tissue Blocks: Towards High-Resolution Whole-Organ 3D Histological Images
    Hashimoto, Noriaki
    Bautista, Pinky A.
    Haneishi, Hideaki
    Snuderl, Matija
    Yagi, Yukako
    PATHOBIOLOGY, 2016, 83 (2-3) : 127 - 139
  • [46] Comparison of Communication Viewsheds Derived from High-Resolution Digital Surface Models Using Line-of-Sight, 2D Fresnel Zone, and 3D Fresnel Zone Analysis
    Baek, Jieun
    Choi, Yosoon
    ISPRS INTERNATIONAL JOURNAL OF GEO-INFORMATION, 2018, 7 (08)
  • [47] 3D Nanostructured Polypyrrole/Sodium Alginate Conducting Hydrogel from self-assembly with High Supercapacitor Performance
    Huang, Huabo
    Yao, Junlong
    Liu, Yulan
    Tuo, Xin
    Da, Yumin
    Zeng, Xiaoping
    Li, Liang
    JOURNAL OF MACROMOLECULAR SCIENCE PART B-PHYSICS, 2017, 56 (08): : 532 - 540
  • [48] 3D Foam Anode and Hydrogel Electrolyte for High-Performance and Stable Flexible Zinc-Air Battery
    Qu, Shengxiang
    Liu, Bin
    Fan, Xiayue
    Liu, Xiaorui
    Liu, Jie
    Ding, Jia
    Han, Xiaopeng
    Deng, Yida
    Hu, Wenbin
    Zhong, Cheng
    CHEMISTRYSELECT, 2020, 5 (27): : 8305 - 8310
  • [49] High-Resolution 3D Unenhanced ECG-Gated Respiratory-Navigated MR Angiography of the Renal Arteries: Comparison With Contrast-Enhanced MR Angiography
    Mohrs, Oliver K.
    Petersen, Steffen E.
    Schulze, Thomas
    Zieschang, Michael
    Kuex, Harald
    Schmitt, Peter
    Bergemann, Sabine
    Kauczor, Hans-Ulrich
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1423 - 1428
  • [50] Assessment of the 3-D reconstruction and high-resolution geometrical modeling of the human skeletal trunk from 2-D radiographic images
    Delorme, S
    Petit, Y
    de Guise, JA
    Labelle, H
    Aubin, CÉ
    Dansereau, J
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (08) : 989 - 998