Use of spectral transmittance model to improve the detection accuracy of chromium in soil

被引:0
|
作者
Yao, Mingyin [1 ]
Wan, Qi [1 ]
Liu, Muhua [1 ]
Wang, Xiao [1 ]
Xu, Jiang [1 ]
机构
[1] Jiangxi Agr Univ, Sch Engn, Higher Educ Key Lab Opt Elect Applicat Biomat, Nanchang 330045, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
BREAKDOWN; LIBS;
D O I
10.1364/AO.542806
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
As a new quantitative analysis method for heavy-metal elements in soil, the main function of the polarization resolution model is to filter out the disturbance of other elements on the spectral signal of target plasma. In order to quantify the mechanism of improving detection performance, the spectral transmittance of plasma intensity in the polarization-resolved optical path has been derived, and the relationship between the intensity of polarization-resolved laser-induced breakdown spectroscopy (PRLIBS) and the characteristic peak wavelength has been defined. Using the spectral data in the wavelength range of 424.50-429.24 nm as the characteristic signal, a quantitative analysis method for detection of the Cr element in soil has been developed. The improvement of spectral intensity stability at the characteristic peak of Cr I 425.7 was analyzed, and the mechanism of enhancing the detection accuracy was elucidated. Research has shown that, based on the polarization characteristics of Cr element plasma, PRLIBS is not affected by the matrix effects of soil and characterizes the amplitude conversion from the reference concentration of Cr element to the plasma spectral intensity. The spectral transmittance of plasma spectra depends not only on the characteristic peak wavelength and complex refractive index of heavy-metal elements but also on the measurement conditions such as spatial geometric angles and reflectivity of the transmission medium. (c) 2024 Optica Publishing Group. All rights, including for text and data mining (TDM), Artificial Intelligence (AI) training, and similar technologies, are reserved.
引用
收藏
页码:8442 / 8446
页数:5
相关论文
共 50 条
  • [1] THE USE OF CORRELATIONS TO IMPROVE THE PRECISION AND ACCURACY OF EMISSION SPECTRAL-ANALYSIS
    ZHIGLINSKY, AG
    BODIN, NS
    KALMAKOV, AA
    TSARYEV, VI
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1982, 37 (12) : 1029 - 1035
  • [2] HIGH-ACCURACY SPECTROMETER FOR MEASUREMENT OF REGULAR SPECTRAL TRANSMITTANCE
    MANOOCHEHRI, F
    IKONEN, E
    APPLIED OPTICS, 1995, 34 (19): : 3686 - 3692
  • [3] High-accuracy measurement of specular spectral reflectance and transmittance
    Haapalinna, A
    Manoochehri, F
    Ikonen, E
    ANALYTICA CHIMICA ACTA, 1999, 380 (2-3) : 317 - 325
  • [4] Constructing Soil-Landscape Units Based on Slope Position and Land Use to Improve Soil Prediction Accuracy
    Zhu, Changda
    Zhu, Fubin
    Li, Cheng
    Lu, Wenhao
    Fang, Zihan
    Li, Zhaofu
    Pan, Jianjun
    REMOTE SENSING, 2024, 16 (21)
  • [5] Parameterized transmittance model for direct beam and circumsolar spectral irradiance
    Gueymard, CA
    SOLAR ENERGY, 2001, 71 (05) : 325 - 346
  • [6] Spectral transmittance model for stacks of transparencies printed with halftone colors
    Machizaud, Jacques
    Hebert, Mathieu
    COLOR IMAGING XVII: DISPLAYING, PROCESSING, HARDCOPY, AND APPLICATIONS, 2012, 8292
  • [7] VOIGT PROFILES OF SPECTRAL-LINES - ACCURACY OF LINE PARAMETERS AS A FUNCTION OF PEAK TRANSMITTANCE
    WILCZEK, E
    BELBRUNO, JJ
    GELFAND, J
    APPLIED SPECTROSCOPY, 1981, 35 (04) : 443 - 444
  • [8] Plant nutrition indices using leaf spectral transmittance for nitrogen detection
    He D.
    Hu J.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2011, 27 (04): : 214 - 218
  • [9] The use of auxiliary geophysical data to improve a soil-landscape model
    Chaplot, V
    Walter, C
    Curmi, P
    Hollier-Larousse, A
    SOIL SCIENCE, 2000, 165 (12) : 961 - 970
  • [10] A Model to Improve the Accuracy of WSN Simulations
    Gama, Oscar
    Carvalho, Paulo
    Mendes, P. M.
    WIRED/WIRELESS INTERNET COMMUNICATIONS, 2011, 6649 : 128 - 139