Human Biomonitoring of Serum Polybrominated Diphenyl Ethers by Supported Liquid Extraction and Gas Chromatography Coupled With Tandem Mass Spectrometry

被引:0
|
作者
Liu, Miao [1 ]
Jia, Xiangyu [1 ,2 ]
Peng, Rongfei [1 ]
Bai, Zhijun [1 ]
Yuan, Jun [1 ]
Tan, Lei [1 ,2 ]
机构
[1] Guangzhou Ctr Dis Control & Prevent, Guangzhou, Peoples R China
[2] Guangzhou Med Univ, Sch Publ Hlth, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
human biomonitoring; liquid-liquid extraction; polybrominated diphenyl ethers; sample preparation; supported liquid extraction; SOLID-PHASE EXTRACTION; SAMPLE PREPARATION; FLAME RETARDANTS; PRODUCTION AREA; PBDES; METABOLITES; EXPOSURE; DUST; MILK; SOIL;
D O I
10.1002/jssc.70010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study aims to develop and validate a robust analytical method for the quantification of polybrominated diphenyl ethers (PBDEs) in human serum using gas chromatography-tandem mass spectrometry. We compared procedural blanks, recoveries, and operational convenience of liquid-liquid extraction and supported liquid extraction for the determination of serum PBDEs. We evaluated different extraction solvents for their effect on PBDE recoveries. Supported liquid extraction was selected for method validation due to its operational convenience. The method demonstrated satisfactory linearity, sensitivity, and reproducibility, with the range of 0.10-5.00 mu g/L for most PBDE congeners and 0.20-10.0 mu g/L for PBDE-154 and PBDE-183, with limits of detection ranging from 2 to 48 ng/L, and with matrix effects ranging from 94% to 113%. Quality control assessments indicated that recoveries ranged from 85% to 110% and relative standard deviations of less than 11%. The proposed method was applied to biomonitoring of 111 healthy adults, revealing detectable levels of PBDEs in over 90% of the samples. BDE-47 and BDE-183 were the most prevalent, with mean concentrations of 4.13 and 22.1 ng/L, respectively. Detection frequencies ranged from 0.90% for BDE-17 and BDE-85 to 25.2% for BDE-47. Males had higher mean concentrations of BDE-183 than females.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Determination of Hydroxylated Polybrominated Diphenyl Ethers in Soils by QuEChERS-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Xu Neng-Bin
    Qian Fei-Zhong
    Feng Jia-Yong
    Wang Sheng-Le
    Hong Zheng-Fang
    Xu Li-Hong
    Chen Zhong-Quan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (02) : 251 - 256
  • [42] Simultaneous determination of trace polybrominated diphenyl ethers in serum using gas chromatography-negative chemical ionization mass spectrometry with simplified sample preparation
    Miao, Wenbin
    Wu, Chunhua
    Yang, Jieling
    Lou, Dan
    Jiang, Wei
    Zhou, Zhijun
    ANALYTICAL METHODS, 2015, 7 (14) : 5907 - 5912
  • [43] Determination of 25 polybrominated diphenyl ethers in Chinese mitten crab ecosystems by gas chromatography-mass spectrometry
    Zhang, Qicai
    Song, Weiguo
    Wang, Xianli
    Liu, Chengbin
    Chen, Shanshan
    Li, Huaxi
    Rao, Qinxiong
    ANALYTICAL METHODS, 2023, 15 (36) : 4700 - 4709
  • [44] Determination of polybrominated diphenyl ethers and polychlorinated biphenyls in fishery and aquaculture products using sequential solid phase extraction and large volume injection gas chromatography/tandem mass spectrometry
    Lu, Dasheng
    Lin, Yuanjie
    Feng, Chao
    Wang, Dongli
    Qiu, Xinlei
    Jin, Yu'e
    Xiong, Libei
    Jin, Ying
    Wang, Guoquan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 945 : 75 - 83
  • [45] Determination of Polybrominated Biphenyls and Polybrominated Diphenyl Ethers in Textiles by Microwave-assisted Extraction and Gas Chromatography
    Shao Chao-Ying
    Shao Yu-Wan
    Zhang Zhuo
    Wen Xiao-Hua
    He Zhong-Fa
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (04) : 522 - 526
  • [46] Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography-tandem mass spectrometry
    Fontana, Ariel R.
    Lana, Nerina B.
    Martinez, Luis D.
    Altamirano, Jorgelina C.
    TALANTA, 2010, 82 (01) : 359 - 366
  • [47] A pretreatment method combined matrix solid-phase dispersion with dispersive liquid-liquid micro-extraction for polybrominated diphenyl ethers in vegetables through quantitation of gas chromatography-tandem mass spectrometry (GC-MS)
    Xu, Sijie
    Wang, Junxia
    Deng, Dengxian
    Sun, Yueying
    Wang, Xuedong
    Zhang, Zhanen
    RSC ADVANCES, 2023, 13 (23) : 15772 - 15782
  • [48] Determination of novel brominated flame retardants and polybrominated diphenyl ethers in serum using gas chromatography-mass spectrometry with two simplified sample preparation procedures
    Gao, Le
    Li, Jian
    Wu, Yandan
    Yu, Miaohao
    Chen, Tian
    Shi, Zhixiong
    Zhou, Xianqing
    Sun, Zhiwei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (27) : 7835 - 7844
  • [49] Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with Solid Phase Extraction
    Xie Lin-Na
    Zhang Hai-Jing
    Hou Sha-Sha
    Zhu Ying
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (12) : 1967 - 1972
  • [50] Determination of polybrominated diphenyl ethers in human blood by gas chromatography-negative chemical ionization-mass spectrometry
    Qu Wei-Yue
    Bi Xin-Hui
    Sheng Guo-Ying
    Lu Shao-You
    Fu Jia-Mo
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 1015 - 1017