Human Biomonitoring of Serum Polybrominated Diphenyl Ethers by Supported Liquid Extraction and Gas Chromatography Coupled With Tandem Mass Spectrometry

被引:0
|
作者
Liu, Miao [1 ]
Jia, Xiangyu [1 ,2 ]
Peng, Rongfei [1 ]
Bai, Zhijun [1 ]
Yuan, Jun [1 ]
Tan, Lei [1 ,2 ]
机构
[1] Guangzhou Ctr Dis Control & Prevent, Guangzhou, Peoples R China
[2] Guangzhou Med Univ, Sch Publ Hlth, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
human biomonitoring; liquid-liquid extraction; polybrominated diphenyl ethers; sample preparation; supported liquid extraction; SOLID-PHASE EXTRACTION; SAMPLE PREPARATION; FLAME RETARDANTS; PRODUCTION AREA; PBDES; METABOLITES; EXPOSURE; DUST; MILK; SOIL;
D O I
10.1002/jssc.70010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study aims to develop and validate a robust analytical method for the quantification of polybrominated diphenyl ethers (PBDEs) in human serum using gas chromatography-tandem mass spectrometry. We compared procedural blanks, recoveries, and operational convenience of liquid-liquid extraction and supported liquid extraction for the determination of serum PBDEs. We evaluated different extraction solvents for their effect on PBDE recoveries. Supported liquid extraction was selected for method validation due to its operational convenience. The method demonstrated satisfactory linearity, sensitivity, and reproducibility, with the range of 0.10-5.00 mu g/L for most PBDE congeners and 0.20-10.0 mu g/L for PBDE-154 and PBDE-183, with limits of detection ranging from 2 to 48 ng/L, and with matrix effects ranging from 94% to 113%. Quality control assessments indicated that recoveries ranged from 85% to 110% and relative standard deviations of less than 11%. The proposed method was applied to biomonitoring of 111 healthy adults, revealing detectable levels of PBDEs in over 90% of the samples. BDE-47 and BDE-183 were the most prevalent, with mean concentrations of 4.13 and 22.1 ng/L, respectively. Detection frequencies ranged from 0.90% for BDE-17 and BDE-85 to 25.2% for BDE-47. Males had higher mean concentrations of BDE-183 than females.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Determination of newly synthesized dihydroxylated polybrominated diphenyl ethers in sea fish by gas chromatography-tandem mass spectrometry
    Zhang, Mengtao
    Guo, Wei
    Wei, Juntong
    Shi, Jianghong
    Zhang, Jiawei
    Ge, Hui
    Tao, Huanyu
    Liu, Xiaowei
    Hu, Qing
    Cai, Zongwei
    CHEMOSPHERE, 2020, 240
  • [32] Selective determination of mono- and dihydroxylated analogs of polybrominated diphenyl ethers in marine sponges by liquid-chromatography tandem mass spectrometry
    Kato, Yoshihisa
    Okada, Syohei
    Atobe, Kazutaka
    Endo, Tetsuya
    Haraguchi, Koichi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (01) : 197 - 206
  • [33] Picogram per liter level determination of hydroxylated polybrominated diphenyl ethers in water by liquid chromatography-electrospray tandem mass spectrometry
    Chang, Hong
    Wu, Fengchang
    Jin, Fen
    Feng, Chenglian
    Zhao, Xiaoli
    Liao, Haiqing
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1223 : 131 - 135
  • [34] Development of an analytical method for the determination of polybrominated diphenyl ethers in sewage sludge by the use of gas chromatography coupled to inductively coupled plasma mass spectrometry
    Novak, Petra
    Zuliani, Tea
    Milacic, Radmila
    Scancar, Janez
    ANALYTICA CHIMICA ACTA, 2016, 915 : 27 - 35
  • [35] Consecutive Online Separation and Determination of Polybrominated Diphenyl Ethers, Phthalate Esters and Bisphenol A in Human Serum by Gas Chromatography-Mass Spectrometry
    Shao Min
    Chen Yong-Heng
    Li Xiao-Yu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (08) : 1139 - 1145
  • [36] Design of experiment approach for the optimization of polybrominated diphenyl ethers determination in fine airborne particulate matter by microwave-assisted extraction and gas chromatography coupled to tandem mass spectrometry
    Beser, Maria Isabel
    Beltran, Joaquim
    Yusa, Vicent
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1323 : 1 - 10
  • [37] Determination of Polybrominated Diphenyl Ethers in Sewage Sludge by High Resolution Gas Chromatography Coupled with High Resolution Mass Spectrometry
    Wang Yawei
    Zhang Qinghua
    Liu Hanxia
    Jiang Guibin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (05) : 492 - 495
  • [38] Development of an analytical method for the determination of polybrominated diphenyl ethers in mussels and fish by gas chromatography-Inductively coupled plasma mass spectrometry
    Novak, Petra
    Zuliani, Tea
    Milacic, Radmila
    Scancar, Janez
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1524 : 179 - 187
  • [39] Determination of polybrominated diphenyl ethers in water and soil samples by cloud point extraction-ultrasound-assisted back-extraction-gas chromatography-mass spectrometry
    Fontana, Ariel R.
    Silva, Maria F.
    Martinez, Luis D.
    Wuilloud, Rodolfo G.
    Altamirano, Jorgelina C.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (20) : 4339 - 4346
  • [40] Analysis of hydroxylated polybrominated diphenyl ethers in rat plasma by using ultra performance liquid chromatography-tandem mass spectrometry
    Lai, Yongquan
    Chen, Xueguo
    Lam, Michael Hon-Wah
    Cai, Zongwei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (15-16): : 1086 - 1090