Research on Wideband Error Calibration System of Current Transformer

被引:0
作者
Wang, Siqi [1 ]
Jiang, Chunyang [1 ,2 ]
Nie, Gaoning [1 ]
Chen, Xiwen [1 ]
Xia, Shengguo [2 ]
机构
[1] China Electric Power Research Institute Co., Ltd., Wuhan
[2] College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan
来源
Gaodianya Jishu/High Voltage Engineering | 2024年 / 50卷 / 12期
关键词
current transformer; electronic compensation; error test; harmonic current; transformer calibration;
D O I
10.13336/j.1003-6520.hve.20231600
中图分类号
学科分类号
摘要
With the extensive application of power electronic equipment, the influence of harmonic current increases gradually. The calibration system of current instrument transformer under harmonic conditions needs to develop to meet needs of measurement capacity. However, traditional calibration equipment can only be utilized to perform tests at power frequency. To solve the problem in measurement characteristic tests of current instrument transformer under harmonic conditions, a wideband current transformer error calibration system is proposed and developed based on high-accuracy active compensation current transformation method. The high-accuracy current transformation section is emphatically introduced in this paper. First, based on the active compensation method, a wideband zero-flux current transformer is designed, and its theoretical model is developed. Moreover, a wideband compensation method of traditional trans-impedance amplifier is proposed. In the circuit loop, an in-phase amplifier is added, and the compensation effect is theoretically calculated and simulated. The compensation method can be adopted to significantly reduce the amplitude and phase errors of the trans-impedance amplifier. The test results indicate that the measurement uncertainty of the calibration system under power frequency is 2.6×10−6 and 2.1 μrad, respectively, and, the uncertainty is 30×10−6 and 20 μrad within the range of 10 kHz, respectively. © 2024 Science Press. All rights reserved.
引用
收藏
页码:5281 / 5288
页数:7
相关论文
共 50 条
  • [31] Saturation Test Under High Current for Current Transformer Detection System Based on LabVIEW
    Wang, Kui
    Tang, Jinrui
    Chen, Guoyan
    Hou, Hui
    Yang, Fanqi
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1861 - 1864
  • [32] Error comparison and analysis of high-voltage current transformer based on different testing methods
    Liu G.
    Xiong X.
    Liao R.
    Hao J.
    Liu K.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (03): : 103 - 107and113
  • [33] Research on nonlinear correction method of current transformer based on support vector machine
    Liu J.
    Pei J.
    Tian M.
    Zhu X.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2020, 24 (10): : 130 - 138
  • [34] Research and development of prejudging device for open circuit in secondary side of current transformer
    Lin, Gaoxiang
    Qian, Bifu
    Wang, Rongtao
    Liu, Xijia
    Wang, Jiaxing
    Lecture Notes in Electrical Engineering, 2015, 334 : 103 - 112
  • [35] Modeling of the Current Transformer
    Prochazka, Martin
    PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2006, 2006, : 407 - 409
  • [36] Comparison of different current transformer modeling techniques for protection system studies
    Kojovic, LA
    2002 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2002, : 1084 - 1089
  • [37] A High-Precision Error Calibration Technique for Current Transformers under the Influence of DC Bias
    Dang, Sanlei
    Xiao, Yong
    Wang, Baoshuai
    Zhang, Dingqu
    Zhang, Bo
    Hu, Shanshan
    Song, Hongtian
    Xu, Chi
    Cai, Yiqin
    ENERGIES, 2023, 16 (24)
  • [38] Development of optical fiber current transformer for DC railway power system
    Technical Center, R and D Center of JR East Group, 2-0, Nisshin, Saitama-shi, Saitama 331-8513, Japan
    不详
    不详
    不详
    不详
    不详
    不详
    IEEJ Trans. Electron. Inf. Syst., 2006, 6 (736-743+8): : 736 - 743+8
  • [39] Study on Field Calibration Technology of Zero Flux DC Current Transformer in ±500kV Converter Station
    Yu, Jicheng
    Yue, Changxi
    Li, He
    Xiong, Kui
    Zhu, Kai
    Zhang, Songhui
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 1941 - 1945
  • [40] Effects of geomagnetically induced current on transferring characteristics of current transformer and transformer differential protection
    Zheng, Tao
    Chen, Peilu
    Liu, Lianguang
    Mao, Anlan
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (22): : 84 - 89