Research on Wideband Error Calibration System of Current Transformer

被引:0
作者
Wang, Siqi [1 ]
Jiang, Chunyang [1 ,2 ]
Nie, Gaoning [1 ]
Chen, Xiwen [1 ]
Xia, Shengguo [2 ]
机构
[1] China Electric Power Research Institute Co., Ltd., Wuhan
[2] College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan
来源
Gaodianya Jishu/High Voltage Engineering | 2024年 / 50卷 / 12期
关键词
current transformer; electronic compensation; error test; harmonic current; transformer calibration;
D O I
10.13336/j.1003-6520.hve.20231600
中图分类号
学科分类号
摘要
With the extensive application of power electronic equipment, the influence of harmonic current increases gradually. The calibration system of current instrument transformer under harmonic conditions needs to develop to meet needs of measurement capacity. However, traditional calibration equipment can only be utilized to perform tests at power frequency. To solve the problem in measurement characteristic tests of current instrument transformer under harmonic conditions, a wideband current transformer error calibration system is proposed and developed based on high-accuracy active compensation current transformation method. The high-accuracy current transformation section is emphatically introduced in this paper. First, based on the active compensation method, a wideband zero-flux current transformer is designed, and its theoretical model is developed. Moreover, a wideband compensation method of traditional trans-impedance amplifier is proposed. In the circuit loop, an in-phase amplifier is added, and the compensation effect is theoretically calculated and simulated. The compensation method can be adopted to significantly reduce the amplitude and phase errors of the trans-impedance amplifier. The test results indicate that the measurement uncertainty of the calibration system under power frequency is 2.6×10−6 and 2.1 μrad, respectively, and, the uncertainty is 30×10−6 and 20 μrad within the range of 10 kHz, respectively. © 2024 Science Press. All rights reserved.
引用
收藏
页码:5281 / 5288
页数:7
相关论文
共 20 条
[11]  
YUE Changxi, ZHOU Feng, Et al., A method of precision measurement for voltage ratio, Electrical Measurement & Instrumentation, 50, 3, pp. 37-40, (2013)
[12]  
MOHNS E, YUE C, ZHOU F, Et al., A current transformer test set for the audio frequency range, Proceedings of 2012 Conference on Precision Electromagnetic Measurements, pp. 302-303, (2012)
[13]  
LI Xuan, LI Hui, BI Jiangang, Et al., Analysis of error characteristics of standard voltage transformers under low frequency conditions, High Voltage Engineering, 49, 9, pp. 3719-3729, (2023)
[14]  
BACHMAIR H., Untersuchung des Fehler- und Stabilitätsverhaltens von elektronisch fehlerkompensierten Stromwandlern, (1977)
[15]  
MOORE W J M, MILJANIC P N., The current comparator (IEE electrical measurement), (1988)
[16]  
SHI Jun, PENG Jingyu, The design of a 50 Hz frequency trap filter based on double T net, Science & Technology Information, 21, pp. 121-122, (2011)
[17]  
WANG Lanruo, LI Dang, ZHANG Shuhua, Et al., Research on current sensor for in-device measurement based on tunnelling magnetoresistance effect, Electric Power Information and Communication Technology, 20, 1, pp. 100-106, (2022)
[18]  
FAN Hao, Application of nanocrystalline alloy core in electric power transformer, Mechanical Engineering & Automation, 6, pp. 201-202, (2015)
[19]  
FRANCO S., Design with operational amplifiers and analog integrated circuits, (2004)
[20]  
Basic knowledge and professional practice of a first-class certified metrologist, (2017)