Research on Wideband Error Calibration System of Current Transformer

被引:0
作者
Wang, Siqi [1 ]
Jiang, Chunyang [1 ,2 ]
Nie, Gaoning [1 ]
Chen, Xiwen [1 ]
Xia, Shengguo [2 ]
机构
[1] China Electric Power Research Institute Co., Ltd., Wuhan
[2] College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan
来源
Gaodianya Jishu/High Voltage Engineering | 2024年 / 50卷 / 12期
关键词
current transformer; electronic compensation; error test; harmonic current; transformer calibration;
D O I
10.13336/j.1003-6520.hve.20231600
中图分类号
学科分类号
摘要
With the extensive application of power electronic equipment, the influence of harmonic current increases gradually. The calibration system of current instrument transformer under harmonic conditions needs to develop to meet needs of measurement capacity. However, traditional calibration equipment can only be utilized to perform tests at power frequency. To solve the problem in measurement characteristic tests of current instrument transformer under harmonic conditions, a wideband current transformer error calibration system is proposed and developed based on high-accuracy active compensation current transformation method. The high-accuracy current transformation section is emphatically introduced in this paper. First, based on the active compensation method, a wideband zero-flux current transformer is designed, and its theoretical model is developed. Moreover, a wideband compensation method of traditional trans-impedance amplifier is proposed. In the circuit loop, an in-phase amplifier is added, and the compensation effect is theoretically calculated and simulated. The compensation method can be adopted to significantly reduce the amplitude and phase errors of the trans-impedance amplifier. The test results indicate that the measurement uncertainty of the calibration system under power frequency is 2.6×10−6 and 2.1 μrad, respectively, and, the uncertainty is 30×10−6 and 20 μrad within the range of 10 kHz, respectively. © 2024 Science Press. All rights reserved.
引用
收藏
页码:5281 / 5288
页数:7
相关论文
共 20 条
[1]  
CHEN Bin, CHEN Jian, LIANG Xu, Et al., Harmonic loss model of winding and core of high-power three-phase medium-frequency transformer, High Voltage Engineering, 48, 8, pp. 3119-3131, (2022)
[2]  
YANG Ling, HUANG Juntao, ZHU Difan, Power division coordination and harmonic current suppression strategy for hybrid energy storage system based on composite virtual impedance, High Voltage Engineering, 49, 5, pp. 2017-2028, (2023)
[3]  
ZHAO Haibo, ZHANG Wanqi, SHEN Di, Et al., Harmonic characteristics analysis and modeling of EMU arrester, High Voltage Engineering, 48, 10, pp. 3891-3899, (2022)
[4]  
ZHAO Xiumin, Principle and application of transformer calibrator, (1982)
[5]  
XIA Qian, SHEN Aonan, TANG Xianfeng, Et al., Internal state monitoring system of fiber optic current transformer based on GOOSE protocol, Electric Power Information and Communication Technolog, 21, 12, pp. 1-8, (2023)
[6]  
CHEN Fusheng, OU Chaolong, WAN Quan, Et al., Design and development of calibrator for the electronic transformer, Electrical Measurement & Instrumentation, 48, 1, pp. 55-58, (2011)
[7]  
LEI Min, JIANG Chunyang, LI Dengyun, Et al., Review of high voltage ratio standard devices technology, High Voltage Engineering, 47, 6, pp. 1893-1904, (2021)
[8]  
ARISTOY G, SANTOS A, TRIGO L, Et al., Behavior of current transformers under distorted waveforms, Proceedings of 2015 IEEE PES Innovative Smart Grid Technologies Latin America, pp. 660-663, (2015)
[9]  
CHEN Y Y, DUBOWIK A, MOHNS E., Reference system for current sensor calibrations at power frequency and for wideband frequencies, Proceedings of the 20th International Conference on Harmonics & Quality of Power, pp. 1-6, (2022)
[10]  
CROTTI G, GALLO D, GIORDANO D, Et al., Industrial comparator for smart grid sensor calibration, IEEE Sensors Journal, 17, 23, pp. 7784-7793, (2017)