Biomechanical Finite Element Analysis of Two Types of Short-Angled Implants Across Various Bone Classifications

被引:0
作者
Ceddia, Mario [1 ]
Romasco, Tea [2 ,3 ]
De Bortoli Jr, Nilton [4 ]
Mello, Bruno Freitas [5 ]
Piattelli, Adriano [6 ,7 ]
Mijiritsky, Eitan [8 ,9 ]
Di Pietro, Natalia [2 ,3 ]
Trentadue, Bartolomeo [1 ]
机构
[1] Politecn Bari Univ, Dept Mech Math & Management, I-70125 Bari, Italy
[2] G dAnnunzio Univ Chieti Pescara, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, Italy
[3] G dAnnunzio Univ Chieti Pescara, Ctr Adv Studies & Technol CAST, I-66100 Chieti, Italy
[4] Assoc Paulista Cirurgioes Dent APCD, Dept Oral Implantol, BR-02011000 Sao Bernardo Do Campo, Brazil
[5] Univ Vale Itajai, Dept Periodont & Implant Dent, BR-88302901 Itajai, Brazil
[6] St Camillus Int Univ Hlth & Med Sci, Sch Dent, I-00131 Rome, Italy
[7] UCAM Univ Catolica San Antonio Murcia, Fac Med, Murcia 30107, Spain
[8] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sch Med, Dept Head & Neck Surg & Maxillofacial Surg, IL-64239 Tel Aviv, Israel
[9] Tel Aviv Univ, Fac Med, Goldschleger Sch Dent Med, IL-39040 Tel Aviv, Israel
关键词
finite element analysis (FEA); dental implants; dental stress analysis; short implants; angled implants; inclined abutments; MACHINED-SURFACE IMPLANTS; STRESS-DISTRIBUTION; DENTAL IMPLANTS; AUGMENTED BONE; DIAMETER; TOOTH; QUALITY; CONNECTIONS; RESORPTION; GEOMETRY;
D O I
10.3390/ma17235680
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this finite element analysis (FEA) was to investigate the distribution of von Mises stress within dental implant components, as well as trabecular and cortical bone. The study considered various bone qualities that influence cortical thickness in contact with the implant, specifically examining cortical thicknesses of 0.5, 1.5, and 3 mm, corresponding to Bergkvist's classifications IV, III, and II, respectively. A simplified 3D model of the bone was developed for the analysis. Two short implants were inserted into the model: one with a 30 degrees inclined abutment (IA) and another positioned at a 30 degrees angle featuring a straight abutment (II). A vertical force (120 N) was applied to the upper surface of the abutments. FEA software was employed to assess the stresses on the peri-implant tissues and the implants. The findings indicated that a reduction in cortical bone thickness results in an increase in stress within the cortical bone. For IA, the stresses recorded 32.56, 56.12, and 96.14 MPa for cortical thicknesses of 3, 1.5, and 0.5 mm, respectively. Conversely, II exhibited increased stresses across all bone qualities (52.32, 76.15, and 126.32 MPa for the same cortical thicknesses). It is advisable to avoid II in cases of poor bone quality and thin cortical due to the heightened risk of overload-induced bone resorption; however, it may be preferable to use IA in scenarios involving good bone quality and thicker cortical.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] The evaluation of stress on bone level and tissue level short implants: A Finite Element Analysis (FEA) study
    Avag, Canseda
    Akkocaoglu, Murat
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (01)
  • [42] Bone quality effect on short implants in the edentulous mandible: a finite element study
    Chaowei Liu
    Yifeng Xing
    Yan Li
    Yanjun Lin
    Jianghan Xu
    Dong Wu
    BMC Oral Health, 22
  • [43] Clinical challenges of biomechanical performance of narrow-diameter implants in maxillary posterior teeth in aging patients: A finite element analysis
    Prasitwuttisak, Saranyoo
    Chantarapanich, Nattapon
    Apinyauppatham, Komsan
    Poomparnich, Kopchai
    Inglam, Samroeng
    PLOS ONE, 2024, 19 (03): : 1 - 17
  • [44] Stress analysis in bone tissue around single implants with different diameters and veneering materials: A 3-D finite element study
    Santiago Junior, Joel Ferreira
    Pellizzer, Eduardo Piza
    Verri, Fellippo Ramos
    Perri de Carvalho, Paulo Sergio
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (08): : 4700 - 4714
  • [45] Three-Dimensional Finite Element Analysis of the Effect of Endosteal Implants with Different Macro Designs on Stress Distribution in Different Bone Qualities
    Yalcin, Mustafa
    Kaya, Beyza
    Lacin, Nihat
    Ari, Emre
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) : E43 - E50
  • [46] The Effect of Placement Depth of Platform- Switched Implants on Periimplant Cortical Bone Stress: A 3-Dimensional Finite Element Analysis
    Rismanchian, Mansour
    Askari, Navid
    Shafiei, Soufia
    IMPLANT DENTISTRY, 2013, 22 (02) : 165 - 169
  • [47] Finite Element Analysis of Bone Stress in the Posterior Mandible Using Regular and Short Implants, in the Same Context, with Splinted and Nonsplinted Prostheses
    Toniollo, Marcelo Bighetti
    Macedo, Ana Paula
    Pupim, Denise
    Zaparolli, Danilo
    Chiarello de Mattos, Maria da Gloria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : E199 - E206
  • [48] Evaluation of Biomechanical Health Degree of Peri-Implant Bone Through Finite Element Analysis: A First Approach
    Lin, Junxiong
    Zhang, Ge
    Jiang, Zhenyu
    Tang, Liqun
    Lian, Keqian
    INTERNATIONAL JOURNAL OF APPLIED MECHANICS, 2018, 10 (09)
  • [49] Comparative Finite Element Analysis of Short Implants with Different Treatment Approaches in the Atrophic Mandible
    Doganay, Ozge
    Kilic, Erdem
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (04) : E69 - E76
  • [50] Investigating the Influence of All-Ceramic Prosthetic Materials on Implants and Their Effect on the Surrounding Bone: A Finite Element Analysis
    Juneja, Saniya
    Miranda, Glynis
    Eram, Afiya
    Shetty, Nisha
    Chethan, K. N.
    Keni, Laxmikant G.