Biomechanical Finite Element Analysis of Two Types of Short-Angled Implants Across Various Bone Classifications

被引:0
|
作者
Ceddia, Mario [1 ]
Romasco, Tea [2 ,3 ]
De Bortoli Jr, Nilton [4 ]
Mello, Bruno Freitas [5 ]
Piattelli, Adriano [6 ,7 ]
Mijiritsky, Eitan [8 ,9 ]
Di Pietro, Natalia [2 ,3 ]
Trentadue, Bartolomeo [1 ]
机构
[1] Politecn Bari Univ, Dept Mech Math & Management, I-70125 Bari, Italy
[2] G dAnnunzio Univ Chieti Pescara, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, Italy
[3] G dAnnunzio Univ Chieti Pescara, Ctr Adv Studies & Technol CAST, I-66100 Chieti, Italy
[4] Assoc Paulista Cirurgioes Dent APCD, Dept Oral Implantol, BR-02011000 Sao Bernardo Do Campo, Brazil
[5] Univ Vale Itajai, Dept Periodont & Implant Dent, BR-88302901 Itajai, Brazil
[6] St Camillus Int Univ Hlth & Med Sci, Sch Dent, I-00131 Rome, Italy
[7] UCAM Univ Catolica San Antonio Murcia, Fac Med, Murcia 30107, Spain
[8] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Sch Med, Dept Head & Neck Surg & Maxillofacial Surg, IL-64239 Tel Aviv, Israel
[9] Tel Aviv Univ, Fac Med, Goldschleger Sch Dent Med, IL-39040 Tel Aviv, Israel
关键词
finite element analysis (FEA); dental implants; dental stress analysis; short implants; angled implants; inclined abutments; MACHINED-SURFACE IMPLANTS; STRESS-DISTRIBUTION; DENTAL IMPLANTS; AUGMENTED BONE; DIAMETER; TOOTH; QUALITY; CONNECTIONS; RESORPTION; GEOMETRY;
D O I
10.3390/ma17235680
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this finite element analysis (FEA) was to investigate the distribution of von Mises stress within dental implant components, as well as trabecular and cortical bone. The study considered various bone qualities that influence cortical thickness in contact with the implant, specifically examining cortical thicknesses of 0.5, 1.5, and 3 mm, corresponding to Bergkvist's classifications IV, III, and II, respectively. A simplified 3D model of the bone was developed for the analysis. Two short implants were inserted into the model: one with a 30 degrees inclined abutment (IA) and another positioned at a 30 degrees angle featuring a straight abutment (II). A vertical force (120 N) was applied to the upper surface of the abutments. FEA software was employed to assess the stresses on the peri-implant tissues and the implants. The findings indicated that a reduction in cortical bone thickness results in an increase in stress within the cortical bone. For IA, the stresses recorded 32.56, 56.12, and 96.14 MPa for cortical thicknesses of 3, 1.5, and 0.5 mm, respectively. Conversely, II exhibited increased stresses across all bone qualities (52.32, 76.15, and 126.32 MPa for the same cortical thicknesses). It is advisable to avoid II in cases of poor bone quality and thin cortical due to the heightened risk of overload-induced bone resorption; however, it may be preferable to use IA in scenarios involving good bone quality and thicker cortical.
引用
收藏
页数:19
相关论文
共 50 条
  • [11] Effects of assessing the bone remodeling process in biomechanical finite element stability evaluations of dental implants
    Park, Soyeon
    Park, Jieun
    Kang, Inyeong
    Lee, Hyeonjong
    Noh, Gunwoo
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 221
  • [12] Biomechanical finite element analysis of small diameter and short dental implant
    Hasan, Istabrak
    Heinemann, Friedhelm
    Aitlahrach, Maria
    Bourauel, Christoph
    BIOMEDIZINISCHE TECHNIK, 2010, 55 (06): : 341 - 350
  • [13] Finite element analysis on influence of implant surface treatments, connection and bone types
    Santiago Junior, Joel Ferreira
    Verri, Fellippo Ramos
    de Faria Almeida, Daniel Augusto
    de Souza Batista, Victor Eduardo
    Araujo Lemos, Cleidiel Aparecido
    Pellizzer, Eduardo Piza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 63 : 292 - 300
  • [14] Biomechanical analysis of different fixed dental restorations on short implants: a finite element study
    Wagner, Christian
    Herberg, Samira
    Bourauel, Christoph
    Stark, Helmut
    Doersam, Istabrak
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (03): : 241 - 250
  • [15] Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study
    Gumrukcu, Zeynep
    Korkmaz, Yavuz Tolga
    Korkmaz, Fatih Mehmet
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 86 : 47 - 54
  • [16] Analysis of Short Implants and Lateralization of the Inferior Alveolar Nerve With 2-Stage Dental Implants by Finite Element Method
    Amorim Vasco, Marco Antonio
    Hecke, Mildred Ballin
    Bezzon, Osvaldo Luiz
    JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (06) : 2064 - 2071
  • [17] The Effect of Three Different Crown Heights and Two Different Bone Types on Implants Placed in the Posterior Maxilla: Three-Dimensional Finite Element Analysis
    Cinar, Duygu
    Imirzalioglu, Pervin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (02) : E1 - E10
  • [18] Two dental implants designed for immediate loading: A finite element analysis
    Pierrisnard, L
    Hure, G
    Barquins, M
    Chappard, D
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2002, 17 (03) : 353 - 362
  • [19] Effect of angled abutments in the posterior maxillary region on tilted implants: a 3D finite element analysis
    Chen, Peng
    Zhang, Jianguo
    Yao, Juan
    Hu, Fengling
    Song, Liang
    Yu, Youcheng
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (08) : 2585 - 2597
  • [20] Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone
    Schwitalla, A. D.
    Abou-Emara, M.
    Spintig, T.
    Lackmann, J.
    Mueller, W. D.
    JOURNAL OF BIOMECHANICS, 2015, 48 (01) : 1 - 7