High-performance thin-layer chromatography and high-performance liquid chromatography determination of two anthocyanins in medicine mulberry

被引:0
|
作者
Zhang, Chunzi [1 ]
Mamattursun, Asiya [1 ]
Ma, Xiaoyan [1 ]
Pang, Tuxia [1 ]
Wu, Yukun [1 ]
Ma, Xiaoli [1 ]
机构
[1] Xinjiang Med Univ, Coll Pharm, Urumqi 830011, Peoples R China
关键词
Cyanidin-3-O-glicoside; Cyanidin-3-O-rutinoside; High-performance thin-layer chromatography (HPTLC); High-performance liquid chromatography (HPLC); Methodological validation;
D O I
10.1007/s00764-024-00316-w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-performance thin-layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC) were established for the simultaneous determination of two anthocyanins in medicine mulberry, a specialty medicinal herb of Xinjiang. For the HPTLC method, a silica gel GF(254) plate was used with formic acid-water-n-butanol (9.1:8.4:32.5, V/V) as the unfolding system, and the dispensing volume was 2 mu L, which was unfolded at room temperature, and then examined under visible light, and scanned at 550 nm for quantitative analysis. HPLC method was performed on a Hypersil ODS2 C18 column (4.6 mm x 250 mm, 5 mu m) with isocratic elution of acetonitrile-0.2% aqueous phosphoric acid (9:91, V/V) at a flow rate of 1.0 mL/min with an injection volume of 10 mu L, column temperature of 30 degrees C, and the analytes were analyzed by an ultraviolet detector at 520 nm. Both developed methods were also validated for the specificity, linearity and range, limit of detection (LOD) and limit of quantification (LOQ), intra- and interday precision, recovery, and stability. Results showed that the HPTLC methods for cyanidin-3-O-glicoside (C3G) and cyanidin-3-O-rutinoside (C3R) showed good linearity (R-2 = 0.9988 and R-2 = 0.9983) in the range of 0.2-1.0 mu g/spot; LOD values of C3G and C3R were 0.048 mu g/spot and 0.036 mu g/spot, LOQ values were 0.15 mu g/spot and 0.11 mu g/spot; intra-day precision (percentage relative standard deviation; %RSD) values were 1.32 and 3.62, inter-day precision (%RSD) values were 2.67 and 3.04, respectively; recoveries for C3G and C3R were 93.33-102.78% and 95.83-103.3%; and the sample solutions were stable within 90 min. The HPLC method showed good linearity (R-2 = 0.9991, R-2 = 0.9993) in the ranges of 12.24-42.84 mu g/mL for C3G and 8.16-28.56 mu g/mL for C3R, respectively. LOD values of C3G and C3R were 1.27 mu g/mL and 0.73 mu g/mL and LOQ values were 3.81 mu g/mL and 2.20 mu g/mL, respectively. Intra-day precision (%RSD) values were 0.64 and 0.98, and inter-day precision (%RSD) values were 0.54 and 0.65, respectively. Recoveries of C3G and C3R were 94.57-98.85% and 93.27-101.4%, the mixed standard solution was stable within 24 h, and the sample solution was stable within 8 h. The results of methodological validation were in agreement with the 2020 edition of the Chinese Pharmacopoeia, and two methods can be used for the determination of the content of medicine mulberry anthocyanins.
引用
收藏
页码:345 / 355
页数:11
相关论文
共 50 条
  • [41] Development and validation of an assay for the quantification of glycosides using high-performance thin-layer chromatography (HPTLC)
    Sharmin Sultana
    Kevin Foster
    Md Lokman Hossain
    Lee Yong Lim
    Cornelia Locher
    JPC – Journal of Planar Chromatography – Modern TLC, 2023, 36 : 179 - 190
  • [42] Gradient high-performance thin-layer chromatography for characterizing complex hydrocarbon-containing products
    Carmen Jarne
    Vicente L. Cebolla
    Luis Membrado
    José M. Escuín
    Jesús Vela
    JPC – Journal of Planar Chromatography – Modern TLC, 2023, 36 : 335 - 349
  • [43] Development and validation of an assay for the quantification of glycosides using high-performance thin-layer chromatography (HPTLC)
    Sultana, Sharmin
    Foster, Kevin
    Hossain, Md Lokman
    Lim, Lee Yong
    Locher, Cornelia
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2023, 36 (2-3) : 179 - 190
  • [44] Determination of Pharmaceuticals by Dynamic Cell Membrane Chromatography Coupled with High-Performance Liquid Chromatography
    Deng, Binge
    Gan, Yuan
    Zhang, Meng
    Ye, Liming
    ANALYTICAL LETTERS, 2018, 51 (08) : 1109 - 1121
  • [45] Validated High-Performance Thin-Layer Chromatography Method for the Determination of Nicotine in Tobacco (Nicotiana tabacum L.) Extracts
    Lionel Paillat
    Christine Périchet
    Sophie Lavoine
    Uwe Meierhenrich
    Xavier Fernandez
    JPC – Journal of Planar Chromatography – Modern TLC, 2012, 25 : 23 - 29
  • [46] Validated High-Performance Thin-Layer Chromatography Method for the Determination of Nicotine in Tobacco (Nicotiana tabacum L.) Extracts
    Paillat, Lionel
    Perichet, Christine
    Lavoine, Sophie
    Meierhenrich, Uwe
    Fernandez, Xavier
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2012, 25 (01) : 23 - 29
  • [47] Determination of benzimidazoles in pharmaceuticals and human serum by high-performance liquid chromatography
    Sher, Nawab
    Fatima, Nasreen
    Perveen, Shahnaz
    Siddiqui, Farhan Ahmed
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2016, 44 (06) : 672 - 682
  • [48] Exploring antioxidant potential in two basidiomycetous mushrooms using high-performance thin-layer chromatography-DPPH-videodensitometry
    Kruzselyi, Daniel
    Ott, Peter G.
    Moricz, Agnes M.
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2023, 36 (05) : 401 - 414
  • [49] Quantification of Sertraline in Human Serum by High-Performance Thin-Layer Chromatography as a Tool for Pharmacotherapy Adherence Evaluation
    Mennickent, Sigrid
    Fierro, Ricardo
    Vega, Mario
    De Diego, Marta
    Gloria Godoy, C.
    Cifuentes, Cristina
    Miranda, Arnoldo
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2013, 26 (04) : 358 - 362
  • [50] Complementary developing solvents for simpler and more powerful routine analysis by high-performance thin-layer chromatography
    Thi Kieu Tiên Do
    Marco Schmid
    Ilona Trettin
    Mona Hänni
    Eike Reich
    JPC – Journal of Planar Chromatography – Modern TLC, 2022, 35 : 299 - 311