High-performance thin-layer chromatography and high-performance liquid chromatography determination of two anthocyanins in medicine mulberry

被引:0
|
作者
Zhang, Chunzi [1 ]
Mamattursun, Asiya [1 ]
Ma, Xiaoyan [1 ]
Pang, Tuxia [1 ]
Wu, Yukun [1 ]
Ma, Xiaoli [1 ]
机构
[1] Xinjiang Med Univ, Coll Pharm, Urumqi 830011, Peoples R China
关键词
Cyanidin-3-O-glicoside; Cyanidin-3-O-rutinoside; High-performance thin-layer chromatography (HPTLC); High-performance liquid chromatography (HPLC); Methodological validation;
D O I
10.1007/s00764-024-00316-w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-performance thin-layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC) were established for the simultaneous determination of two anthocyanins in medicine mulberry, a specialty medicinal herb of Xinjiang. For the HPTLC method, a silica gel GF(254) plate was used with formic acid-water-n-butanol (9.1:8.4:32.5, V/V) as the unfolding system, and the dispensing volume was 2 mu L, which was unfolded at room temperature, and then examined under visible light, and scanned at 550 nm for quantitative analysis. HPLC method was performed on a Hypersil ODS2 C18 column (4.6 mm x 250 mm, 5 mu m) with isocratic elution of acetonitrile-0.2% aqueous phosphoric acid (9:91, V/V) at a flow rate of 1.0 mL/min with an injection volume of 10 mu L, column temperature of 30 degrees C, and the analytes were analyzed by an ultraviolet detector at 520 nm. Both developed methods were also validated for the specificity, linearity and range, limit of detection (LOD) and limit of quantification (LOQ), intra- and interday precision, recovery, and stability. Results showed that the HPTLC methods for cyanidin-3-O-glicoside (C3G) and cyanidin-3-O-rutinoside (C3R) showed good linearity (R-2 = 0.9988 and R-2 = 0.9983) in the range of 0.2-1.0 mu g/spot; LOD values of C3G and C3R were 0.048 mu g/spot and 0.036 mu g/spot, LOQ values were 0.15 mu g/spot and 0.11 mu g/spot; intra-day precision (percentage relative standard deviation; %RSD) values were 1.32 and 3.62, inter-day precision (%RSD) values were 2.67 and 3.04, respectively; recoveries for C3G and C3R were 93.33-102.78% and 95.83-103.3%; and the sample solutions were stable within 90 min. The HPLC method showed good linearity (R-2 = 0.9991, R-2 = 0.9993) in the ranges of 12.24-42.84 mu g/mL for C3G and 8.16-28.56 mu g/mL for C3R, respectively. LOD values of C3G and C3R were 1.27 mu g/mL and 0.73 mu g/mL and LOQ values were 3.81 mu g/mL and 2.20 mu g/mL, respectively. Intra-day precision (%RSD) values were 0.64 and 0.98, and inter-day precision (%RSD) values were 0.54 and 0.65, respectively. Recoveries of C3G and C3R were 94.57-98.85% and 93.27-101.4%, the mixed standard solution was stable within 24 h, and the sample solution was stable within 8 h. The results of methodological validation were in agreement with the 2020 edition of the Chinese Pharmacopoeia, and two methods can be used for the determination of the content of medicine mulberry anthocyanins.
引用
收藏
页码:345 / 355
页数:11
相关论文
共 50 条
  • [1] DETERMINATION OF GRISEOFULVIN IN RAT PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY
    KREUZIG, F
    JOURNAL OF CHROMATOGRAPHY, 1979, 163 (03): : 322 - 326
  • [2] QUANTITATIVE-DETERMINATION OF CUCURBITACINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY
    HALAWEISH, FT
    TALLAMY, DW
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (02): : 497 - 511
  • [3] HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY
    COSTANZO, SJ
    JOURNAL OF CHEMICAL EDUCATION, 1984, 61 (11) : 1015 - 1018
  • [4] HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY
    FENIMORE, DC
    DAVIS, CM
    ANALYTICAL CHEMISTRY, 1981, 53 (02) : A252 - &
  • [5] DETERMINATION OF PENTACHLOROPHENOL BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY
    PEREZ, M
    BARRIOS, C
    SAELZER, R
    VEGA, M
    VILLEGAS, R
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1989, 12 (06): : 419 - 421
  • [6] DETERMINATION OF COUMESTROL IN SOYBEANS BY HIGH-PERFORMANCE LIQUID AND THIN-LAYER CHROMATOGRAPHY
    LOOKHART, GL
    JONES, BL
    FINNEY, KF
    CEREAL CHEMISTRY, 1978, 55 (06) : 967 - 972
  • [7] Determination of Lormetazepam in Tablets Using High-Performance Thin-Layer Chromatography, High-Performance Liquid Chromatography, and Derivative Spectrophotometry Methods
    Gackowski, Marcin
    Koba, Marcin
    Madra-Gackowska, Katarzyna
    Pluskota, Robert
    Glowczewska-Siedlecka, Emilia
    Siedlecki, Zygmunt
    Marsza, Michal P.
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2018, 31 (03) : 235 - 242
  • [8] Determination of Lormetazepam in Tablets Using High-Performance Thin-Layer Chromatography, High-Performance Liquid Chromatography, and Derivative Spectrophotometry Methods
    Marcin Gackowski
    Marcin Koba
    Katarzyna Mądra-Gackowska
    Robert Pluskota
    Emilia Główczewska-Siedlecka
    Zygmunt Siedlecki
    Michał P. Marszałł
    JPC – Journal of Planar Chromatography – Modern TLC, 2018, 31 : 235 - 242
  • [9] Pressurized planar electrochromatography, high-performance thin-layer chromatography and high-performance liquid chromatography-Comparison of performance
    Plocharz, Pawel
    Klimek-Turek, Anna
    Dzido, Tadeusz H.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (29) : 4868 - 4872
  • [10] Assay of tinidazole in human serum by high-performance thin-layer chromatography - Comparison with high-performance liquid chromatography
    Univ. Sci. Technol. Houari Boumed., Institut de Chimie, B.P. No. 32, El-Alia, Bab-Ezzouar, Alger 16111, Algeria
    J AOAC Int, 2 (244-247):