Integrating forecasting methods to support finite element analysis and explore heat transfer complexities

被引:1
作者
Fatima, Maryam [1 ]
Kim, Peter S. [2 ]
Lei, Youming [1 ]
Siddiqui, A. M. [3 ]
Sohail, Ayesha [2 ,4 ]
机构
[1] Northwestern Polytech Univ, Sch Math & Stat, Xian, Peoples R China
[2] Univ Sydney, Sch Math & Stat, Sydney, Australia
[3] Penn State Univ, York, PA USA
[4] Univ Sydney, Sydney, Australia
基金
澳大利亚研究理事会;
关键词
Numerical analysis; Finite element methods; Radiofrequency ablation; Deep learning; Surrogate models; Bioheat transfer; TUMOR ABLATION; MICROWAVE ABLATION; THIN-FILMS; RADIOFREQUENCY; PHANTOM; LIVER; TEMPERATURE; SYSTEM; GEL;
D O I
10.1108/HFF-06-2024-0477
中图分类号
O414.1 [热力学];
学科分类号
摘要
PurposeThis paper aims to reduce the cost of experiments required to test the efficiency of materials suitable for artificial tissue ablation by increasing efficiency and accurately forecasting heating properties.Design/methodology/approachA two-step numerical analysis is used to develop and simulate a bioheat model using improved finite element method and deep learning algorithms, systematically regulating temperature distributions within the hydrogel artificial tissue during radiofrequency ablation (RFA). The model connects supervised learning and finite element analysis data to optimize electrode configurations, ensuring precise heat application while protecting surrounding hydrogel integrity.FindingsThe model accurately predicts a range of thermal changes critical for optimizing RFA, thereby enhancing treatment precision and minimizing impact on surrounding hydrogel materials. This computational approach not only advances the understanding of thermal dynamics but also provides a robust framework for improving therapeutic outcomes.Originality/valueA computational predictive bioheat model, incorporating deep learning to optimize electrode configurations and minimize collateral tissue damage, represents a pioneering approach in interventional research. This method offers efficient evaluation of thermal strategies with reduced computational overhead compared to traditional numerical methods.
引用
收藏
页码:4281 / 4305
页数:25
相关论文
共 84 条
  • [1] Structural, optical and photoelectrochemical properties of tungsten oxide thin films grown by non-reactive RF-sputtering
    Acosta, M.
    Acosta Mendez, Rocio
    Riech, I.
    Rodriguez-Perez, Manuel
    Rodriguez-Gattorno, Geonel
    [J]. SUPERLATTICES AND MICROSTRUCTURES, 2019, 127 : 123 - 127
  • [2] Comparative analysis of entropy generation and heat transfer in a tilted partially heated square enclosure using the finite difference method
    Algehyne, Ebrahem A.
    [J]. INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2024, 34 (04) : 1752 - 1779
  • [3] Complication Rates and Risk of Recurrence After Percutaneous Radiofrequency Ablation and Microwave Ablation for the Treatment of Liver Tumors: a Meta-analysis
    Alhasan, Ayman S.
    Daqqaq, Tareef S.
    Alhasan, Mustafa S.
    Ghunaim, Hadeel A.
    Aboualkheir, Mervat
    [J]. ACADEMIC RADIOLOGY, 2024, 31 (04) : 1288 - 1301
  • [4] Radiofrequency ablation using a novel insulated-tip ablation catheter can create uniform lesions comparable in size to conventional irrigated ablation catheters while using a fraction of the energy and irrigation
    Aryana, Arash
    Irastorza, Ramiro M.
    Berjano, Enrique
    Cohen, Richard J.
    Kraus, Jeffrey
    Haghighi-Mood, Ali
    Reddy, Vivek Y.
    d'Avila, Andre
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (06) : 1146 - 1156
  • [5] Bansal V., 2011, P COMSOL C
  • [6] Basu S, 2011, CRYSTALLINE SILICON - PROPERTIES AND USES, P1, DOI 10.5772/844
  • [7] A liver-mimicking MRI phantom for thermal ablation experiments
    Bazrafshan, Babak
    Huebner, Frank
    Farshid, Parviz
    Larson, Maya C.
    Vogel, Vitali
    Maentele, Werner
    Vogl, Thomas J.
    [J]. MEDICAL PHYSICS, 2011, 38 (05) : 2674 - 2684
  • [8] Bignozzi M., 2015, TRIBOL IND, V37, P482
  • [9] Thermal Tumor Ablation in Clinical Use
    Brace, Chris
    [J]. IEEE PULSE, 2011, 2 (05) : 28 - 38
  • [10] Radiofrequency and Microwave Ablation of the Liver, Lung, Kidney, and Bone: What Are the Differences?
    Brace, Christopher L.
    [J]. CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2009, 38 (03) : 135 - 143