A simple, robust and high-throughput LC-MS/MS method for the therapeutic drug monitoring of polymyxin B1, polymyxin B2, polymyxin B3, isoleucine-polymyxin B1, polymyxin E1 and polymyxin E2 in human plasma

被引:0
|
作者
Chen, Feng [1 ]
Li, Huanhuan [2 ,3 ]
Yang, Xiaoxia [4 ]
Deng, Ziwei [1 ,5 ]
Wang, Hongqiang [1 ,5 ]
Shi, Zhihua [1 ,5 ]
Qiu, Chengfeng [1 ,5 ]
机构
[1] Hunan Univ, Dept Clin Pharm, Med Gen Hosp, Huaihua, Hunan, Peoples R China
[2] Cent South Univ, Xiangya Sch Pharmaceut Sci, Changsha, Hunan, Peoples R China
[3] Queens Univ Belfast, Sch Pharm, Belfast, North Ireland
[4] Hunan Univ, Dept Endocrine Metab & Clin Nutr, Med Gen Hosp, Huaihua, Peoples R China
[5] Hunan Univ, Med Gen Hosp, Dept Evidence Based Med & Clin Ctr, Huaihua, Peoples R China
关键词
LC-MS/MS; polymyxin B; polymyxin E; therapeutic drug monitoring; COLISTIN METHANESULFONATE; SIMULTANEOUS QUANTITATION; CONSENSUS GUIDELINES; VALIDATION; URINE; COMPONENTS; ASSAY;
D O I
10.1002/bmc.6034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To facilitate clinical therapeutic drug monitoring (TDM) of polymyxin B (PB) and polymyxin E (PE), we developed and validated a simple LC-MS/MS method for simultaneous determination of PB (including polymyxin B1 (PB1), polymyxin B2 (PB2), polymyxin B3 (PB3) and isoleucine-polymyxin B1 (ile-PB1)) and PE (including polymyxin E1 (PE1) and polymyxin E2 (PE2)) in human plasma. PB or PE was extracted from 20.0 mu L plasma using a 5% (v/v) formic acid acetonitrile solution and separated on a BEH-C18 column (2.1 x 100 mm, 1.7 mu m) with a mobile phase consisting of 0.8% formic acid aqueous solution and 0.2% formic acid acetonitrile solution. Gradient elution was performed over 5.5 min at a flow rate of 0.250 mL/min. Quantitative analysis was conducted in positive ion scanning mode by electrospray ionization and multiple reaction monitoring. The method validation was conducted based on bioanalytical method validation guidance, including specificity, calibration curve, precision, accuracy, recovery, matrix effect, stability and dilution integrity and all of the results satisfied the requirements. The method was simple, robust and high-throughput and is currently being used to provide a TDM service to enhancing therapeutic efficacy and safety use of the PB and PE.
引用
收藏
页数:13
相关论文
共 21 条
  • [21] Development and Validation of a UPLC-MS/MS and UPLC-HR-MS Method for the Determination of Fumonisin B1 and Its Hydrolysed Metabolites and Fumonisin B2 in Broiler Chicken Plasma
    De Baere, Siegrid
    Croubels, Siska
    Novak, Barbara
    Bichl, Gerlinde
    Antonissen, Gunther
    TOXINS, 2018, 10 (02):