A simple, robust and high-throughput LC-MS/MS method for the therapeutic drug monitoring of polymyxin B1, polymyxin B2, polymyxin B3, isoleucine-polymyxin B1, polymyxin E1 and polymyxin E2 in human plasma

被引:0
|
作者
Chen, Feng [1 ]
Li, Huanhuan [2 ,3 ]
Yang, Xiaoxia [4 ]
Deng, Ziwei [1 ,5 ]
Wang, Hongqiang [1 ,5 ]
Shi, Zhihua [1 ,5 ]
Qiu, Chengfeng [1 ,5 ]
机构
[1] Hunan Univ, Dept Clin Pharm, Med Gen Hosp, Huaihua, Hunan, Peoples R China
[2] Cent South Univ, Xiangya Sch Pharmaceut Sci, Changsha, Hunan, Peoples R China
[3] Queens Univ Belfast, Sch Pharm, Belfast, North Ireland
[4] Hunan Univ, Dept Endocrine Metab & Clin Nutr, Med Gen Hosp, Huaihua, Peoples R China
[5] Hunan Univ, Med Gen Hosp, Dept Evidence Based Med & Clin Ctr, Huaihua, Peoples R China
关键词
LC-MS/MS; polymyxin B; polymyxin E; therapeutic drug monitoring; COLISTIN METHANESULFONATE; SIMULTANEOUS QUANTITATION; CONSENSUS GUIDELINES; VALIDATION; URINE; COMPONENTS; ASSAY;
D O I
10.1002/bmc.6034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To facilitate clinical therapeutic drug monitoring (TDM) of polymyxin B (PB) and polymyxin E (PE), we developed and validated a simple LC-MS/MS method for simultaneous determination of PB (including polymyxin B1 (PB1), polymyxin B2 (PB2), polymyxin B3 (PB3) and isoleucine-polymyxin B1 (ile-PB1)) and PE (including polymyxin E1 (PE1) and polymyxin E2 (PE2)) in human plasma. PB or PE was extracted from 20.0 mu L plasma using a 5% (v/v) formic acid acetonitrile solution and separated on a BEH-C18 column (2.1 x 100 mm, 1.7 mu m) with a mobile phase consisting of 0.8% formic acid aqueous solution and 0.2% formic acid acetonitrile solution. Gradient elution was performed over 5.5 min at a flow rate of 0.250 mL/min. Quantitative analysis was conducted in positive ion scanning mode by electrospray ionization and multiple reaction monitoring. The method validation was conducted based on bioanalytical method validation guidance, including specificity, calibration curve, precision, accuracy, recovery, matrix effect, stability and dilution integrity and all of the results satisfied the requirements. The method was simple, robust and high-throughput and is currently being used to provide a TDM service to enhancing therapeutic efficacy and safety use of the PB and PE.
引用
收藏
页数:13
相关论文
共 21 条
  • [1] Development and validation of liquid chromatography tandem mass spectrometry method quantitative determination of polymyxin B1, polymyxin B2, polymyxin B3 and isoleucine-polymyxin B1 in human plasma and its application in clinical studies
    Hee, Kim H.
    Leaw, Yee K. J.
    Ong, Jun L.
    Lee, Lawrence S.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 140 : 91 - 97
  • [2] Therapeutic drug monitoring of polymyxin B by LC-MS/MS in plasma and urine
    Liu, Xiaofen
    Yu, Zhenwei
    Wang, Yu
    Wu, Hailan
    Bian, Xingchen
    Li, Xin
    Fan, Yaxin
    Guo, Beining
    Zhang, Jing
    BIOANALYSIS, 2020, 12 (12) : 845 - 855
  • [3] Simultaneous quantitation of polymyxin B1, polymyxin B2 and polymyxin B1-1 in human plasma and treated human urine using solid phase extraction and liquid chromatography-tandem mass spectrometry
    Meng, Min
    Wang, Laixin
    Liu, Sherry
    Jaber, Othman M.
    Gao, Lihong
    Chevrette, Lynn
    Reuschel, Scott
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1012 : 23 - 36
  • [4] A Simple and Robust Liquid Chromatography With Tandem Mass Spectrometry Analytical Method for Therapeutic Drug Monitoring of Plasma and Cerebrospinal Fluid Polymyxin B1 and B2
    Wang, Peile
    Zhang, Qiwen
    Qin, Zifei
    Xing, Han
    Xu, Min
    Pei, Hui
    Yang, Jing
    Zhang, Xiaojian
    THERAPEUTIC DRUG MONITORING, 2020, 42 (05) : 716 - 723
  • [5] Determination of polymyxin B in dried blood spots using LC-MS/MS for therapeutic drug monitoring
    Huang, Xiaolan
    Liu, Xiaofen
    Wang, Yu
    Zhang, Jing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1192
  • [6] High Performance Liquid Chromatography-Mass Spectrometry Assay for Polymyxin B1 and B2 in Human Plasma
    Thomas, Tiffany A.
    Broun, Emily C.
    Abildskov, Kirsten M.
    Kubin, Christine J.
    Horan, Jennifer
    Yin, Michael T.
    Cremers, Serge
    THERAPEUTIC DRUG MONITORING, 2012, 34 (04) : 398 - 405
  • [7] Does Monitoring Total and Free Polymyxin B1 Plasma Concentrations Predict Polymyxin B-Induced Nephrotoxicity? A Retrospective Study in Critically Ill Patients
    Yang Deng
    Jun-Yuan Gu
    Xin Li
    Huan Tong
    Si-Wei Guo
    Bing Xu
    You Li
    Bi-Kui Zhang
    Ying Li
    Hai-Ying Huang
    Gui-Ying Xiao
    Infectious Diseases and Therapy, 2022, 11 : 1591 - 1608
  • [8] Does Monitoring Total and Free Polymyxin B1 Plasma Concentrations Predict Polymyxin B-Induced Nephrotoxicity? A Retrospective Study in Critically Ill Patients
    Deng, Yang
    Gu, Jun-Yuan
    Li, Xin
    Tong, Huan
    Guo, Si-Wei
    Xu, Bing
    Li, You
    Zhang, Bi-Kui
    Li, Ying
    Huang, Hai-Ying
    Xiao, Gui-Ying
    INFECTIOUS DISEASES AND THERAPY, 2022, 11 (04) : 1591 - 1608
  • [9] Determination of polymyxin B in human plasma and epithelial lining fluid using LC-MS/MS and its clinical application in therapeutic drug monitoring
    Zhang, Bingqing
    Li, Xueyong
    Chen, Yiying
    Chen, Bo
    Cheng, Yu
    Lin, Hailing
    Que, Wancai
    Liu, Maobai
    Zhou, Lili
    Zhang, Hui
    Qiu, Hongqiang
    Wu, Chaoyang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 227
  • [10] The development and validation of a simple liquid chromatography-tandem mass spectrometry method for polymyxin B1 and B2 quantification in different matrices
    Covelli, Jenna
    Ruszaj, Donna
    Straubinger, Robert
    Li, Jian
    Rao, Gauri G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1065 : 112 - 118