Demonstration of a Validated Direct Current Wearable Device for Monitoring Sweat Rate in Sports

被引:1
作者
Xuan, Xing [1 ]
Rojas, Daniel [1 ]
Lozano, Isabel Maria Diaz [1 ]
Cuartero, Maria [1 ,2 ]
Crespo, Gaston A. [1 ,2 ]
机构
[1] Univ Catol San Antonio Murcia, UCAM HiTech, UCAM SENS, Avda Andres Hernandez Ros 1, Murcia 30107, Spain
[2] KTH Royal Inst Technol, Dept Chem, Teknikringen 30, SE-10044 Stockholm, Sweden
基金
欧洲研究理事会; 瑞典研究理事会;
关键词
wearable sensor; sweat analysis; sweat rate; direct current method; microfluidic; EXERCISE;
D O I
10.3390/s24227243
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sweat rate magnitude is a desired outcome for any wearable sensing patch dedicated to sweat analysis. Indeed, sweat rate values can be used two-fold: self-diagnosis of dehydration and correction/normalization of other physiological metrics, such as Borg scale, VO2, and different chemical species concentrations. Herein, a reliable sweat rate belt device for sweat rate monitoring was developed. The device measures sweat rates in the range from 1.0 to 5.0 mu L min(-1) (2 to 10 mu L min(-1) cm(-2)), which covers typical values for humans. The working mechanism is based on a new direct current (DC) step protocol activating a series of differential resistance measurements (spatially separated by 800 mu m) that is gradually initiated by the action of sweat, which flows along a customized microfluidic track (similar to 600 mu m in width, 10 mm in length, and 235 mu m in thickness). The device has a volumetric capacity of similar to 16 mu L and an acquisition frequency between 0.010 and 0.043 Hz within the measured sweat rate range. Importantly, instead of using a typical and rather complex AC signal interrogation and acquisition, we put forward the DC approach, offering several benefits, such as simplified circuit design for easier fabrication and lower costs, as well as reduced power consumption and suitability for wearable applications. For the validation, either the commercial sweat collector (colorimetric) or the developed device was performed. In five on-body tests, an acceptable variation of ca. 10% was obtained. Overall, this study demonstrates the potential of the DC-based device for the monitoring of sweat rate and also its potential for implementation in any wearable sweat platform.
引用
收藏
页数:16
相关论文
共 40 条
[1]  
[Anonymous], 2004, MACRODUCT SWEAT COLLECTION SYSTEM instruction/service manual Model 3700
[2]   Skin-interfaced microfluidic system with personalized sweating rate and sweat chloride analytics for sports science applications [J].
Baker, Lindsay B. ;
Model, Jeffrey B. ;
Barnes, Kelly A. ;
Anderson, Melissa L. ;
Lee, Stephen P. ;
Lee, Khalil A. ;
Brown, Shyretha D. ;
Reimel, Adam J. ;
Roberts, Timothy J. ;
Nuccio, Ryan P. ;
Bonsignore, Justina L. ;
Ungaro, Corey T. ;
Carter, James M. ;
Li, Weihua ;
Seib, Melissa S. ;
Reeder, Jonathan T. ;
Aranyosi, Alexander J. ;
Rogers, John A. ;
Ghaffari, Roozbeh .
SCIENCE ADVANCES, 2020, 6 (50)
[3]   Exercise intensity effects on total sweat electrolyte losses and regional vs. whole-body sweat [Na+], [Cl-], and [K+] [J].
Baker, Lindsay B. ;
De Chavez, Peter John D. ;
Ungaro, Corey T. ;
Sopena, Bridget C. ;
Nuccio, Ryan P. ;
Reimel, Adam J. ;
Barnes, Kelly A. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (02) :361-375
[4]   Resettable Microfluidics for Broad-Range and Prolonged Sweat Rate Sensing [J].
Bariya, Mallika ;
Davis, Noelle ;
Gillan, Liam ;
Jansson, Elina ;
Kokkonen, Annukka ;
McCaffrey, Colm ;
Hiltunen, Jussi ;
Javey, Ali .
ACS SENSORS, 2022, 7 (04) :1156-1164
[5]   Wearable sweat sensors [J].
Bariya, Mallika ;
Nyein, Hnin Yin Yin ;
Javey, Ali .
NATURE ELECTRONICS, 2018, 1 (03) :160-171
[6]   Next-Generation Continuous Metabolite Sensing toward Emerging Sensor Needs [J].
Bhide, Ashlesha ;
Ganguly, Antra ;
Parupudi, Tejasvi ;
Ramasamy, Mohanraj ;
Muthukumar, Sriram ;
Prasad, Shalini .
ACS OMEGA, 2021, 6 (09) :6031-6040
[7]   A Real-TimeWireless Sweat Rate Measurement System for Physical Activity Monitoring [J].
Brueck, Andrew ;
Iftekhar, Tashfin ;
Stannard, Alicja B. ;
Yelamarthi, Kumar ;
Kaya, Tolga .
SENSORS, 2018, 18 (02)
[8]   A Capacitive Sweat Rate Sensor for Continuous and Real-Time Monitoring of Sweat Loss [J].
Choi, Dong-Hoon ;
Gonzales, Mark ;
Kitchen, Grant B. ;
Phan, Dinh-Tuan ;
Searson, Peter C. .
ACS SENSORS, 2020, 5 (12) :3821-3826
[9]   Pre-game hydration status, sweat loss, and fluid intake in elite Brazilian young male soccer players during competition [J].
Da Silva, Rafael P. ;
Muendel, Toby ;
Natali, Antonio J. ;
Bara Filho, Mauricio G. ;
Alfenas, Rita C. G. ;
Lima, Jorge R. P. ;
Belfort, Felipe G. ;
Lopes, Priscila R. N. R. ;
Marins, Joao C. B. .
JOURNAL OF SPORTS SCIENCES, 2012, 30 (01) :37-42
[10]   Mild dehydration impairs cognitive performance and mood of men [J].
Ganio, Matthew S. ;
Armstrong, Lawrence E. ;
Casa, Douglas J. ;
McDermott, Brendon P. ;
Lee, Elaine C. ;
Yamamoto, Linda M. ;
Marzano, Stefania ;
Lopez, Rebecca M. ;
Jimenez, Liliana ;
Le Bellego, Laurent ;
Chevillotte, Emmanuel ;
Lieberman, Harris R. .
BRITISH JOURNAL OF NUTRITION, 2011, 106 (10) :1535-1543