High-quality endoscopic laser speckle contrast imaging with conical fiber illumination

被引:1
作者
Yan, Junshuai [1 ,2 ]
Han, Qinxin [1 ,2 ]
Meng, Liangwei [1 ,2 ]
Sun, Tingyu [1 ,2 ]
Yan, Yan [1 ,2 ]
Feng, Shijie [1 ,2 ]
Yuan, Shaomin [1 ,2 ]
Lu, Jinling [1 ,2 ]
Li, Pengcheng [1 ,2 ,3 ]
机构
[1] Huazhong Univ Sci & Technol, Britton Chance Ctr Biomed Photon, MoE Key Lab Biomed Photon, Adv Biomed Imaging Facil,Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
[2] Chinese Acad Med Sci, JITRI, HUST Suzhou Inst Brainsmat, Res Unit Multimodal Cross Scale Neural Signal Dete, Suzhou 215100, Peoples R China
[3] Hainan Univ, Sch Biomed Engn, State Key Lab Digital Med Engn, Key Lab Biomed Engn Hainan Prov, Sanya 572025, Peoples R China
基金
中国国家自然科学基金;
关键词
MULTIMODE FIBERS; COHERENCE; OUTPUT; INTENSITY; NOISE; TIME;
D O I
10.1364/PRJ.528592
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Blood flow is essential for maintaining normal physiological functions of the human body. Endoscopic laser speckle contrast imaging (LSCI) can achieve rapid, high-resolution, label-free, and long-term blood flow perfusion velocity monitoring in minimally invasive surgery. However, conventional endoscopic LSCI uses a low- coherence laser illumination scheme, leading to restricted angles of illumination, compromised laser coherence, uneven laser illumination distribution, and low coupling efficiency, all of which degrade the quality of LSCI in the endoscope. In this paper, we propose that conical fiber (CF)-coupled high-coherence laser can be used to achieve large-angle, high-coherence, high-uniformity, and high coupling efficiency laser illumination in the endoscope. Additionally, we establish an effective model for calculating the divergence angle of CFs. Through phantom and animal experiments, we reveal that laser illumination based on CF markedly enhances endoscopic LSCI performance. This technology broadens the imaging field of view, enhances the signal-to-noise ratio, enables more sensitive detection of minute blood flow changes, expands the detectable flow range, and improves signal-to-background ratio of endoscopic LSCI. Our findings suggest that CF-based laser illumination stands as a highly promising advancement in endoscopic LSCI. (c) 2025 Chinese Laser Press
引用
收藏
页码:583 / 592
页数:10
相关论文
共 50 条
  • [31] The use of laser speckle contrast imaging to predict flap necrosis: An experimental study in a porcine flap model
    Zotterman, Johan
    Tesselaar, Erik
    Farnebo, Simon
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2019, 72 (05) : 771 - 777
  • [32] Movement correction method for laser speckle contrast imaging of cerebral blood flow in cranial windows in rodents
    Guilbert, Jeremie
    Desjardins, Michele
    JOURNAL OF BIOPHOTONICS, 2022, 15 (01)
  • [33] Imaging the Cerebral Blood Flow With Enhanced Laser Speckle Contrast Analysis (eLASCA) by Monotonic Point Transformation
    Miao, Peng
    Li, Minheng
    Fontenelle, Hugues
    Bezerianos, Anastasios
    Qiu, Yihong
    Tong, Shanbao
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (04) : 1127 - 1133
  • [34] Laser speckle contrast imaging of cerebral blood flow in humans during neurosurgery: a pilot clinical study
    Parthasarathy, Ashwin B.
    Weber, Erica L.
    Richards, Lisa M.
    Fox, Douglas J.
    Dunn, Andrew K.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (06)
  • [35] Feasibility study of hidden flow imaging based on laser speckle technique using multiperspectives contrast images
    Abookasis, David
    Moshe, Tomer
    OPTICS AND LASERS IN ENGINEERING, 2014, 62 : 38 - 45
  • [36] High spatiotemporal resolution imaging of the neurovascular response to electrical stimulation of rat peripheral trigeminal nerve as revealed by in vivo temporal laser speckle contrast
    Li, Nan
    Jia, Xiaofeng
    Murari, Kartikeya
    Parlapalli, Renuka
    Rege, Abhishek
    Thakor, Nitish V.
    JOURNAL OF NEUROSCIENCE METHODS, 2009, 176 (02) : 230 - 236
  • [37] Laser speckle contrast imaging in children with scalds: Its influence on timing of intervention, duration of healing and care, and costs
    Elmasry, Moustafa
    Mirdell, Robin
    Tesselaar, Erik
    Farnebo, Simon
    Sjoberg, Folke
    Steinvall, Ingrid
    BURNS, 2019, 45 (04) : 798 - 804
  • [38] Excellent inter- and intra-observer reproducibility of microvascular tests using laser speckle contrast imaging
    Humeau-Heurtier, Anne
    Abraham, Pierre
    Durand, Sylvain
    Mahe, Guillaume
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2014, 58 (03) : 439 - 446
  • [39] Laser speckle contrast imaging for assessment of abdominal visceral microcirculation in acute peritonitis: does sequential impairments exist?
    Ding, Chao
    Ren, Jianan
    Zhou, Bo
    Wu, Yin
    Shao, Xiaomei
    Wang, Gefei
    Fang, Jianqiao
    Li, Jieshou
    MICROVASCULAR RESEARCH, 2014, 95 : 26 - 30
  • [40] Angular dependence of screen speckle and fiber speckle of coupled output of nine high-power blue laser diodes through a multi-mode fiber
    Junichi Kinoshita
    Hitoshi Aizawa
    Akira Takamori
    Kazuhisa Yamamoto
    Hiroshi Murata
    Koji Tojo
    Optical Review, 2016, 23 : 121 - 132