From model validation to biomechanical analysis: In silico study of multirooted root analogue implants using 3D finite element analysis

被引:0
|
作者
Aldesoki, Mostafa [1 ,2 ]
Keilig, Ludger [1 ,3 ]
Alhotan, Abdulaziz [4 ]
Diab, Al-Hassan [5 ]
Elshazly, Tarek M. [1 ]
Bourauel, Christoph [1 ]
机构
[1] Univ Hosp Bonn, Dent Sch, Oral Technol, Bonn, Germany
[2] LMU Hosp, Clin Conservat Dent & Periodontol, Munich, Germany
[3] Univ Hosp Bonn, Dent Sch, Dept Prosthet Dent Preclin Educ & Mat Sci, Bonn, Germany
[4] King Saud Univ, Coll Appl Med Sci, Dept Dent Hlth, Riyadh, Saudi Arabia
[5] British Univ Egypt, Fac Dent, Dept Oral Med Periodontol & Diag, Cairo, Egypt
关键词
Root analogue implant (RAI); Dental implant; Finite element analysis; Biomechanics; Abutment design; Validation study; DENTAL IMPLANTS; STABILITY; DESIGN;
D O I
10.1016/j.jmbbm.2025.106896
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: To create a validated 3D finite element model and employ it to examine the biomechanical behaviour of multirooted root analogue implants (RAIs). Methods: A validated finite element model comprising either an RAI or a threaded implant (TI) and an idealised bone block was developed based on a previously conducted in vitro study. All the experimental boundary conditions and material properties were reproduced. Force/displacement curves were plotted to ensure complete alignment with the in vitro findings. Following the validation of the FE model, the material properties were adjusted to align with those reported in the literature. Two contact scenarios were then examined: immediate placement with touching contact and osseointegration with glued contact. The bone block was constrained in all directions, and a 300 N point load was applied along the long axis of the implant, and with an angulation of 30 degrees. The resulting values for equivalent stress, maximum principal stress, microstrain, and displacement were evaluated. Results: The numerical model demonstrated a high degree of agreement with the experimental results, particularly regarding displacement in the loading direction (Z). The findings of the applied FEA indicated that RAIs generally outperformed TIs. The RAI exhibited lower equivalent stress, with values of 3.3 MPa for axial loading and 13.1 MPa for oblique loading, compared to 5.4 MPa and 29.5 MPa for the TI, respectively. Furthermore, microstrain was observed to be lower in the RAI, with a value of 4,000 mu 8 compared to 13,000 mu 8 in the TI under oblique loading. Additionally, the RAI exhibited superior primary and secondary stability, with lower micro- motion values compared to the TI. Conclusions: The root analogue implant showed superior biomechanical performance, with more uniform stress distribution and greater stability compared to the conventional threaded implant, positioning it as a promising alternative.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Biomechanical Analysis of the External Fixation in a Lumbar Fracture Model: A Finite Element Study
    Liao, Yijia
    Yan, Yiguo
    Kang, Yu
    Wang, Wenjun
    Song, Xizheng
    Peng, Wen
    Fu, Haibin
    Chen, Huarong
    Wang, Cheng
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (04) : 469 - 478
  • [32] Biomechanical study of spinal cord and nerve root in idiopathic scoliosis: based on finite element analysis
    Ma, Jibin
    Wang, Jian
    Yang, Yuming
    Wu, Jincheng
    Liu, Ziwen
    Miao, Jun
    Yan, Xu
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [33] Biomechanical finite element analysis of small diameter and short dental implants: extensive study of commercial implants
    Bourauel, Christoph
    Aitlahrach, Maria
    Heinemann, Friedhelm
    Hasan, Istabrak
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 (01): : 21 - 32
  • [34] Biomechanical analysis of different fixed dental restorations on short implants: a finite element study
    Wagner, Christian
    Herberg, Samira
    Bourauel, Christoph
    Stark, Helmut
    Doersam, Istabrak
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (03): : 241 - 250
  • [35] Research of Shark Concept Using 3D Finite Element Analysis
    Sejejs, Karlis
    Kamolins, Edmunds
    Gulbis, Karlis
    2018 IEEE 59TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2018,
  • [36] Influence of bicortical techniques in internal connection placed in premaxillary area by 3D finite element analysis
    Verri, Fellippo Ramos
    Cruz, Ronaldo Silva
    Araujo Lemos, Cleidiel Aparecido
    de Souza Batista, Victor Eduardo
    Faria Almeida, Daniel Augusto
    Goncales Verri, Ana Caroline
    Pellizzer, Eduardo Piza
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (02) : 193 - 200
  • [37] Biomechanical Analysis of Volar and Dorsal Double Locking Plates for Fixation in Comminuted Extra-articular Distal Radius Fractures: A 3D Finite Element Study
    Lin, Yu-Hao
    Lin, Chun-Li
    Kuo, Hsien-Nan
    Sun, Ming-Tsung
    Chen, Alvin Chao-Yu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (05) : 349 - 355
  • [38] Biomechanical analysis of a newly designed and 3D printed plate-locking interbody cage: an observational study of finite element analysis
    Ni, Shuai
    Yang, Rui
    Liu, Sanmao
    Hu, Yunxiang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [39] Biomechanical analysis of maxillary first molar intrusion using 3D printed personalized device combined with clear aligner: a finite element study and clinical application
    Qin Xue
    Mei Hu
    Minglu Xu
    Xuyang Zhang
    Huaqiao Wang
    Mimi Sun
    Chunjuan Wang
    Yao He
    Clinical Oral Investigations, 29 (5)
  • [40] Stress distribution and microgap formation in angulated zirconia abutments with a titanium base in narrow diameter implants: A 3D finite element analysis
    Zhang, Yuqiang
    Yu, Ping
    Yu, Haiyang
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2022, 38 (07)