From model validation to biomechanical analysis: In silico study of multirooted root analogue implants using 3D finite element analysis

被引:0
|
作者
Aldesoki, Mostafa [1 ,2 ]
Keilig, Ludger [1 ,3 ]
Alhotan, Abdulaziz [4 ]
Diab, Al-Hassan [5 ]
Elshazly, Tarek M. [1 ]
Bourauel, Christoph [1 ]
机构
[1] Univ Hosp Bonn, Dent Sch, Oral Technol, Bonn, Germany
[2] LMU Hosp, Clin Conservat Dent & Periodontol, Munich, Germany
[3] Univ Hosp Bonn, Dent Sch, Dept Prosthet Dent Preclin Educ & Mat Sci, Bonn, Germany
[4] King Saud Univ, Coll Appl Med Sci, Dept Dent Hlth, Riyadh, Saudi Arabia
[5] British Univ Egypt, Fac Dent, Dept Oral Med Periodontol & Diag, Cairo, Egypt
关键词
Root analogue implant (RAI); Dental implant; Finite element analysis; Biomechanics; Abutment design; Validation study; DENTAL IMPLANTS; STABILITY; DESIGN;
D O I
10.1016/j.jmbbm.2025.106896
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: To create a validated 3D finite element model and employ it to examine the biomechanical behaviour of multirooted root analogue implants (RAIs). Methods: A validated finite element model comprising either an RAI or a threaded implant (TI) and an idealised bone block was developed based on a previously conducted in vitro study. All the experimental boundary conditions and material properties were reproduced. Force/displacement curves were plotted to ensure complete alignment with the in vitro findings. Following the validation of the FE model, the material properties were adjusted to align with those reported in the literature. Two contact scenarios were then examined: immediate placement with touching contact and osseointegration with glued contact. The bone block was constrained in all directions, and a 300 N point load was applied along the long axis of the implant, and with an angulation of 30 degrees. The resulting values for equivalent stress, maximum principal stress, microstrain, and displacement were evaluated. Results: The numerical model demonstrated a high degree of agreement with the experimental results, particularly regarding displacement in the loading direction (Z). The findings of the applied FEA indicated that RAIs generally outperformed TIs. The RAI exhibited lower equivalent stress, with values of 3.3 MPa for axial loading and 13.1 MPa for oblique loading, compared to 5.4 MPa and 29.5 MPa for the TI, respectively. Furthermore, microstrain was observed to be lower in the RAI, with a value of 4,000 mu 8 compared to 13,000 mu 8 in the TI under oblique loading. Additionally, the RAI exhibited superior primary and secondary stability, with lower micro- motion values compared to the TI. Conclusions: The root analogue implant showed superior biomechanical performance, with more uniform stress distribution and greater stability compared to the conventional threaded implant, positioning it as a promising alternative.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Static and Dynamic Stress Analysis of Standard- and Narrow-Diameter Implants: A 3D Finite Element Analysis
    Sahin, Sezgi Cinel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (04) : E58 - E68
  • [22] Biomechanical study of tarsometatarsal joint fusion using finite element analysis
    Wang, Yan
    Li, Zengyong
    Zhang, Ming
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (11) : 1394 - 1400
  • [23] Biomechanical 3D analysis of stress induced by orthodontic implants
    Szuhanek, C.
    Faur, N.
    Cernescu, A.
    ADVANCES IN STRENGTH OF MATERIALS, 2009, 399 : 199 - 204
  • [24] Splinting Effect on Posterior Implants Under Various Loading Modes: A 3D Finite Element Analysis
    Hauchard, Erwan
    Fournier, Benjamin Philippe
    Jacq, Romain
    Bouton, Antoine
    Pierrisnard, Laurent
    Naveau, Adrien
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2011, 19 (03): : 117 - 122
  • [25] Identifying an optimal approach for the placement of pterygoid implants: A 3D finite element analysis
    Chen, Jun
    Bu, Lingtong
    Xu, Guangzhou
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (05): : 917.e1 - 917.e13
  • [26] Rehabilitation of Atrophic Posterior Maxilla with Pterygoid Implants: A 3D Finite Element Analysis
    Wilkirson, Elizabeth
    Chandran, Ravi
    Duan, Yuanyuan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : E51 - E62
  • [27] Biomechanical influence of narrow-diameter implants placed at the crestal and subcrestal level in the maxillary anterior region. A 3D finite element analysis
    Cruz, Ronaldo S.
    Fernandes e Oliveira, Hiskell Francine
    Lemos, Cleidiel Aparecido Araujo
    Batista, Victor Eduardo de Souza
    da Silva, Rodrigo Capalbo
    Verri, Fellippo R.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (02): : 180 - 187
  • [28] Biomechanical Evaluation of the Effects of Implant Neck Wall Thickness and Abutment Screw Size: A 3D Nonlinear Finite Element Analysis
    Jeng, Ming-Dih
    Lin, Yang-Sung
    Lin, Chun-Li
    APPLIED SCIENCES-BASEL, 2020, 10 (10):
  • [29] Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
    Ayali, Aysa
    Bilginaylar, Kani
    HEAD & FACE MEDICINE, 2017, 13
  • [30] Biomechanical Analysis of the External Fixation in a Lumbar Fracture Model: A Finite Element Study
    Yijia Liao
    Yiguo Yan
    Yu Kang
    Wenjun Wang
    Xizheng Song
    Wen Peng
    Haibin Fu
    Huarong Chen
    Cheng Wang
    Journal of Medical and Biological Engineering, 2022, 42 : 469 - 478