We herein fabricated a capacitive solid-state reference electrode by loading a paper strip with carbon nanotubes (CNTs) to increase double-layer capacitance and adsorbing heavy-metal ions thereon to charge the electrical double layer and minimize the effects of other ions on the interfacial potential difference. CNTs were loaded by immersing the paper strip into a CNT solution followed by drying. By repeating these steps up to 20 times and adsorbing Cu2+, we stabilized the electrode potential and minimized the influence of other ions and electroactive compounds. The potential of the best-performing CNT electrode in the presence of different electrolytes and electroactive compounds ranged from 243 to 249 mV, exhibiting a variation of <= 6 mV over 60 min, whereas gold, carbon paste, and copper electrodes exhibited potential variations of tens of mV or larger. The influence of pH was negligible, although that of buffer components was not negligible in some cases. The CNT reference electrode was tested by potentiometric ion sensing and cyclic voltammetry and shown to be a viable alternative to a macroscopic Ag/AgCl electrode. A capacitive solid-state reference electrode was fabricated.A paper strip was loaded with carbon nanotubes to increase double-layer capacitance.Heavy-metal ions were adsorbed to charge the electrical double layer.Dependence of the electrode potential on electrolyte and pH could be minimized.
引用
收藏
页数:9
相关论文
共 50 条
  • [2] Analysis of heavy-metal ions using mercury microelectrodes and a solid-state reference electrode on a Si wafer
    Yun, KS
    Kim, HJ
    Joo, S
    Kwak, J
    Yoon, E
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2000, 39 (12B): : 7159 - 7163
  • [3] A fluorometric paper-based sensor array for the discrimination of heavy-metal ions
    Feng, Liang
    Li, Hui
    Niu, Li-Ya
    Guan, Ying-Shi
    Duan, Chun-Feng
    Guan, Ya-Feng
    Tung, Chen-Ho
    Yang, Qing-Zheng
    TALANTA, 2013, 108 : 103 - 108
  • [4] Enhancement of sensitivity of paper-based sensor array for the identification of heavy-metal ions
    Feng, Liang
    Li, Xiao
    Li, Hui
    Yang, Wei
    Chen, Liang
    Guan, Yafeng
    ANALYTICA CHIMICA ACTA, 2013, 780 : 74 - 80
  • [5] Highly Compressible Solid-State Supercapacitor with Folded Paper-Based Electrode
    Song, Yu
    Cheng, Xiao-Liang
    Chen, Hao-Tian
    Han, Meng-Di
    Chen, Xue-Xian
    Zhang, Hai-Xia
    2016 IEEE 11TH ANNUAL INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2016,
  • [6] An efficient self-made paper-based carbon electrode for electrochemical detection of heavy metal ions
    Wang, Jing
    Lv, Jinyu
    Du, Haiying
    Xu, Shuaikang
    Sun, Pengcheng
    Sun, Yanhui
    Wang, Liding
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2023, 34 (15)
  • [7] An efficient self-made paper-based carbon electrode for electrochemical detection of heavy metal ions
    Jing Wang
    Jinyu Lv
    Haiying Du
    Shuaikang Xu
    Pengcheng Sun
    Yanhui Sun
    Liding Wang
    Journal of Materials Science: Materials in Electronics, 2023, 34
  • [8] Solid-state reference electrodes based on carbon nanotubes and polyacrylate membranes
    F. Xavier Rius-Ruiz
    Anna Kisiel
    Agata Michalska
    Krzystof Maksymiuk
    Jordi Riu
    F. Xavier Rius
    Analytical and Bioanalytical Chemistry, 2011, 399 : 3613 - 3622
  • [9] Solid-state reference electrodes based on carbon nanotubes and polyacrylate membranes
    Rius-Ruiz, F. Xavier
    Kisiel, Anna
    Michalska, Agata
    Maksymiuk, Krzystof
    Riu, Jordi
    Rius, F. Xavier
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (10) : 3613 - 3622
  • [10] Analysis of heavy-metal-ions using mercury microelectrodes and a solid-state reference electrode fabricated on a Si wafer
    Yun, KS
    Kim, HJ
    Joo, S
    Kwak, J
    Yoon, E
    MICROPROCESSES AND NANOTECHNOLOGY 2000, DIGEST OF PAPERS, 2000, : 72 - 73