GateNet: A novel neural network architecture for automated flow cytometry gating

被引:0
|
作者
Fisch L. [1 ]
Heming M. [2 ]
Schulte-Mecklenbeck A. [2 ]
Gross C.C. [2 ]
Zumdick S. [1 ]
Barkhau C. [1 ]
Emden D. [1 ]
Ernsting J. [1 ,3 ,4 ]
Leenings R. [1 ]
Sarink K. [1 ]
Winter N.R. [1 ]
Dannlowski U. [1 ]
Wiendl H. [2 ]
Hörste G.M.Z. [2 ]
Hahn T. [1 ]
机构
[1] University of Münster, Institute for Translational Psychiatry, Münster
[2] Department of Neurology with Institute of Translational Neurology, University and University Hospital Münster, Münster
[3] Institute for Geoinformatics, University of Münster
[4] Faculty of Mathematics and Computer Science, University of Münster
关键词
Flow cytometry; Gating; Machine learning; Neural network;
D O I
10.1016/j.compbiomed.2024.108820
中图分类号
学科分类号
摘要
Background and Objective: Flow cytometry is a widely used technique for identifying cell populations in patient-derived fluids, such as peripheral blood (PB) or cerebrospinal fluid (CSF). Despite its ubiquity in research and clinical practice, the process of gating, i.e., manually identifying cell types, is labor-intensive and error-prone. The objective of this study is to address this challenge by introducing GateNet, a neural network architecture designed for fully end-to-end automated gating without the need for correcting batch effects. Methods: For this study a unique dataset is used which comprises over 8,000,000 events from N = 127 PB and CSF samples which were manually labeled independently by four experts. Applying cross-validation, the classification performance of GateNet is compared to the human experts performance. Additionally, GateNet is applied to a publicly available dataset to evaluate generalization. The classification performance is measured using the F1 score. Results: GateNet achieves F1 scores ranging from 0.910 to 0.997 demonstrating human-level performance on samples unseen during training. In the publicly available dataset, GateNet confirms its generalization capabilities with an F1 score of 0.936. Importantly, we also show that GateNet only requires ≈10 samples to reach human-level performance. Finally, gating with GateNet only takes 15 microseconds per event utilizing graphics processing units (GPU). Conclusions: GateNet enables fully end-to-end automated gating in flow cytometry, overcoming the labor-intensive and error-prone nature of manual adjustments. The neural network achieves human-level performance on unseen samples and generalizes well to diverse datasets. Notably, its data efficiency, requiring only ∼10 samples to reach human-level performance, positions GateNet as a widely applicable tool across various domains of flow cytometry. © 2024 The Author(s)
引用
收藏
相关论文
共 50 条
  • [31] A standardized gating technique for the generation of flow cytometry data for normal canine and normal feline blood lymphocytes
    Byrne, KM
    Kim, HW
    Chew, BP
    Reinhart, GA
    Hayek, MG
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2000, 73 (02) : 167 - 182
  • [32] Automated flow cytometry for monitoring CHO cell cultures
    Kuystermans, Darrin
    Mohd, Avesh
    Al-Rubeai, Mohamed
    METHODS, 2012, 56 (03) : 358 - 365
  • [33] Automated Cough Analysis with Convolutional Recurrent Neural Network
    Wang, Yiping
    Wahab, Mustafaa
    Hong, Tianqi
    Molinari, Kyle
    Gauvreau, Gail M.
    Cusack, Ruth P.
    Gao, Zhen
    Satia, Imran
    Fang, Qiyin
    BIOENGINEERING-BASEL, 2024, 11 (11):
  • [34] Flow cytometry CD45 gating for immunophenotyping of acute myeloid leukemia
    Lacombe, F
    Durrieu, F
    Briais, A
    Dumain, P
    Belloc, F
    Bascans, E
    Reiffers, J
    Boisseau, MR
    Bernard, P
    LEUKEMIA, 1997, 11 (11) : 1878 - 1886
  • [35] Detection of Residual B Precursor Lymphoblastic Leukemia by Uniform Gating Flow Cytometry
    Mejstrikova, Ester
    Fronkova, Eva
    Kalina, Tomas
    Omelka, Marek
    Batinic, Drago
    Dubravcic, Klara
    Pospisilova, Klara
    Vaskova, Martina
    Luria, Drorit
    Cheng, Suk Hang
    Ng, Margaret
    Leung, Yonna
    Kappelmayer, Janos
    Kiss, Flora
    Izraeli, Shai
    Stark, Batia
    Schrappe, Martin
    Trka, Jan
    Stary, Jan
    Hrusak, Ondrej
    PEDIATRIC BLOOD & CANCER, 2010, 54 (01) : 62 - 70
  • [36] Unfold High-Dimensional Clouds for Exhaustive Gating of Flow Cytometry Data
    Qiu, Peng
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2014, 11 (06) : 1045 - 1051
  • [37] Flow cytometry CD45 gating for immunophenotyping of acute myeloid leukemia
    F Lacombe
    F Durrieu
    A Briais
    P Dumain
    F Belloc
    E Bascans
    J Reiffers
    MR Boisseau
    Ph Bernard
    Leukemia, 1997, 11 : 1878 - 1886
  • [38] Advances in Automated Urinalysis Systems, Flow Cytometry and Digitized Microscopy
    Cho, Sun Young
    Hur, Mina
    ANNALS OF LABORATORY MEDICINE, 2019, 39 (01) : 1 - 2
  • [39] The role of automated urine particle flow cytometry in clinical practice
    Delanghe, JR
    Kouri, TT
    Huber, AR
    Hannemann-Pohl, K
    Guder, WG
    Lun, A
    Sinha, P
    Stamminger, G
    Beier, L
    CLINICA CHIMICA ACTA, 2000, 301 (1-2) : 1 - 18
  • [40] A multidimensional classification approach for the automated analysis of flow cytometry data
    Pedreira, Carlos Eduardo
    Costa, Elaine S.
    Arroyo, M. Elena
    Allmeida, Julia
    Orfao, Alberto
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (03) : 1155 - 1162