GateNet: A novel neural network architecture for automated flow cytometry gating

被引:0
|
作者
Fisch L. [1 ]
Heming M. [2 ]
Schulte-Mecklenbeck A. [2 ]
Gross C.C. [2 ]
Zumdick S. [1 ]
Barkhau C. [1 ]
Emden D. [1 ]
Ernsting J. [1 ,3 ,4 ]
Leenings R. [1 ]
Sarink K. [1 ]
Winter N.R. [1 ]
Dannlowski U. [1 ]
Wiendl H. [2 ]
Hörste G.M.Z. [2 ]
Hahn T. [1 ]
机构
[1] University of Münster, Institute for Translational Psychiatry, Münster
[2] Department of Neurology with Institute of Translational Neurology, University and University Hospital Münster, Münster
[3] Institute for Geoinformatics, University of Münster
[4] Faculty of Mathematics and Computer Science, University of Münster
关键词
Flow cytometry; Gating; Machine learning; Neural network;
D O I
10.1016/j.compbiomed.2024.108820
中图分类号
学科分类号
摘要
Background and Objective: Flow cytometry is a widely used technique for identifying cell populations in patient-derived fluids, such as peripheral blood (PB) or cerebrospinal fluid (CSF). Despite its ubiquity in research and clinical practice, the process of gating, i.e., manually identifying cell types, is labor-intensive and error-prone. The objective of this study is to address this challenge by introducing GateNet, a neural network architecture designed for fully end-to-end automated gating without the need for correcting batch effects. Methods: For this study a unique dataset is used which comprises over 8,000,000 events from N = 127 PB and CSF samples which were manually labeled independently by four experts. Applying cross-validation, the classification performance of GateNet is compared to the human experts performance. Additionally, GateNet is applied to a publicly available dataset to evaluate generalization. The classification performance is measured using the F1 score. Results: GateNet achieves F1 scores ranging from 0.910 to 0.997 demonstrating human-level performance on samples unseen during training. In the publicly available dataset, GateNet confirms its generalization capabilities with an F1 score of 0.936. Importantly, we also show that GateNet only requires ≈10 samples to reach human-level performance. Finally, gating with GateNet only takes 15 microseconds per event utilizing graphics processing units (GPU). Conclusions: GateNet enables fully end-to-end automated gating in flow cytometry, overcoming the labor-intensive and error-prone nature of manual adjustments. The neural network achieves human-level performance on unseen samples and generalizes well to diverse datasets. Notably, its data efficiency, requiring only ∼10 samples to reach human-level performance, positions GateNet as a widely applicable tool across various domains of flow cytometry. © 2024 The Author(s)
引用
收藏
相关论文
共 50 条
  • [21] Augmented Human Intelligence and Automated Diagnosis in Flow Cytometry for Hematologic Malignancies
    Ng, David P.
    Zuromski, Lauren M.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2021, 155 (04) : 597 - 605
  • [22] Dissecting Response to Cancer Immunotherapy by Applying Bayesian Network Analysis to Flow Cytometry Data
    Rodin, Andrei S.
    Gogoshin, Grigoriy
    Hilliard, Seth
    Wang, Lei
    Egelston, Colt
    Rockne, Russell C.
    Chao, Joseph
    Lee, Peter P.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (05) : 1 - 21
  • [23] Enumeration of monocytes subsets using different gating methods by flow cytometry
    Wang, Hua
    Wang, Saili
    Ye, Jun
    Yin, Yong
    Zhou, Yupei
    Ma, Xiaolan
    Wang, Yan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2016, 9 (02): : 1285 - 1293
  • [24] River flood prediction using fuzzy neural networks: an investigation on automated network architecture
    Khan, Usman T.
    He, Jianxun
    Valeo, Caterina
    WATER SCIENCE AND TECHNOLOGY, 2018, (01) : 238 - 247
  • [25] Automated Hardware and Neural Network Architecture co-design of FPGA accelerators using multi-objective Neural Architecture Search
    Colangelo, Philip
    Segal, Oren
    Speicher, Alex
    Margala, Martin
    2020 IEEE 10TH INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE-BERLIN), 2020,
  • [26] Monochromatic gating method by flow cytometry for high purity monocyte analysis
    Wong, Linda
    Davis, Bruce H.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2013, 84B (02) : 119 - 124
  • [27] CD45 gating for the identification of blastic cells by flow cytometry
    Gerardo Collino, Cesar Juan
    Rodriguez, Cecilia
    Sastre, Dario
    Heller, Viviana
    Fernandez, Enrique
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2006, 40 (02): : 173 - 180
  • [28] Neural network architecture optimization using automated machine learning for borehole resistivity measurements
    Shahriari, M.
    Pardo, D.
    Kargaran, S.
    Teijeiro, T.
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2023, 234 (03) : 2488 - 2501
  • [29] Automated flow cytometry analysis of peritoneal dialysis fluid
    Penders, J
    Fiers, T
    Dhondt, AM
    Claeys, G
    Delanghe, JR
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (02) : 463 - 468
  • [30] Automated clustering of heterotrophic bacterioplankton in flow cytometry data
    Garcia, Francisca C.
    Lopez-Urrutia, Angel
    Moran, Xose Anxelu G.
    AQUATIC MICROBIAL ECOLOGY, 2014, 72 (02) : 175 - 185