Performance evaluation of modified tuned liquid dampers for seismic response control of nonlinear benchmark buildings

被引:0
作者
Daneshmand, A. H. [1 ]
Karamodin, A. [1 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Civil Engn, Mashhad, Iran
关键词
Energy dissipation; Modi ed TunedLiquid Damper(MTLD); Nonlinear benchmarkbuildings; Structural damage; Passive control; SIMULATION;
D O I
10.24200/sci.2023.59989.6548
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Tn this study, the performance of Modified Tuned Liquid Damper (MTLD) is evaluated to control the seismic response of 9- and 20-story nonlinear benchmark buildings. MTLD is a type of Tuned Liquid Damper (TLD) that is equipped with a rotational spring at the base and thus experiences both horizontal and rotational motion with structural vibration. The equations obtained by shallow water wave theory are used to describe the water sloshing in the MTLD tank. The optimal design of main MTLD parameters such as dimensionless rotational stiffness, mass and frequency ratio, and the tank distance from the top of the structure are investigated. Tn addition, the effects of far-field and near-field earthquakes on MTLD performance are discussed and compared with the performance of TLD in detail. The results show that MTLD is somewhat more efficient than TLD both in reducing seismic response and reducing structural damage caused by nonlinear behavior of the structures.
引用
收藏
页码:588 / 602
页数:15
相关论文
共 50 条
[41]   Influence of liquid sloshing in the vertical limbs of tuned liquid column dampers on structural response reduction [J].
Das, Anupam ;
Konar, Tanmoy ;
Pandit, Amiya ;
Maity, Damodar .
ACTA MECHANICA, 2025, 236 (02) :1117-1134
[42]   A methodology of design for seismic performance enhancement of buildings using viscous fluid dampers [J].
Raju, K. Rama ;
Ansu, M. ;
Iyer, Nagesh R. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2014, 21 (03) :342-355
[43]   Simplified nonlinear modeling for estimating the seismic response of buildings [J].
Lin, Jui-Liang ;
Chuang, Ming-Chieh .
ENGINEERING STRUCTURES, 2023, 279
[44]   Multiple tuned inerter-based dampers for seismic response mitigation of continuous girder bridges [J].
Liang, Ruijun ;
Wang, Hao ;
Li, Jian ;
Gao, Hui ;
Zheng, Wenzhi ;
Xu, Zidong .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 151
[45]   Use of pseudo-negative stiffness dampers for reducing the seismic response of bridges: a benchmark study [J].
S. N. Madhekar ;
R. S. Jangid .
Bulletin of Earthquake Engineering, 2012, 10 :1561-1583
[46]   Use of pseudo-negative stiffness dampers for reducing the seismic response of bridges: a benchmark study [J].
Madhekar, S. N. ;
Jangid, R. S. .
BULLETIN OF EARTHQUAKE ENGINEERING, 2012, 10 (05) :1561-1583
[47]   Seismic effectiveness and robustness of tuned mass dampers versus nonlinear energy sinks in a lifecycle cost perspective [J].
Matta, Emiliano .
BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (01) :513-551
[48]   Control of the along-wind response of steel framed buildings by using viscoelastic or friction dampers [J].
Mazza, Fabio ;
Vulcano, Alfonso .
WIND AND STRUCTURES, 2007, 10 (03) :233-247
[49]   Stochastic response control of particle dampers under random seismic excitation [J].
Lu, Zheng ;
Liao, Yuan ;
Huang, Zhikuang .
JOURNAL OF SOUND AND VIBRATION, 2020, 481
[50]   Effective seismic response control of buildings with sliding bearings [J].
Dushimimana, A. ;
Singirankabo, E. ;
Kathumbi, L. .
MAGAZINE OF CIVIL ENGINEERING, 2021, 108 (08)