Performance evaluation of modified tuned liquid dampers for seismic response control of nonlinear benchmark buildings

被引:0
作者
Daneshmand, A. H. [1 ]
Karamodin, A. [1 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Civil Engn, Mashhad, Iran
关键词
Energy dissipation; Modi ed TunedLiquid Damper(MTLD); Nonlinear benchmarkbuildings; Structural damage; Passive control; SIMULATION;
D O I
10.24200/sci.2023.59989.6548
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Tn this study, the performance of Modified Tuned Liquid Damper (MTLD) is evaluated to control the seismic response of 9- and 20-story nonlinear benchmark buildings. MTLD is a type of Tuned Liquid Damper (TLD) that is equipped with a rotational spring at the base and thus experiences both horizontal and rotational motion with structural vibration. The equations obtained by shallow water wave theory are used to describe the water sloshing in the MTLD tank. The optimal design of main MTLD parameters such as dimensionless rotational stiffness, mass and frequency ratio, and the tank distance from the top of the structure are investigated. Tn addition, the effects of far-field and near-field earthquakes on MTLD performance are discussed and compared with the performance of TLD in detail. The results show that MTLD is somewhat more efficient than TLD both in reducing seismic response and reducing structural damage caused by nonlinear behavior of the structures.
引用
收藏
页码:588 / 602
页数:15
相关论文
共 50 条
[31]   Coupled tuned mass dampers for control of coupled vibrations in asymmetric buildings [J].
Desu, Nagendra Babu ;
Deb, S. K. ;
Dutta, Anjan .
STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (05) :897-916
[32]   Optimal assessment and location of tuned mass dampers for seismic response control of a plan-asymmetrical building [J].
Desu, Nagendra Babu ;
Dutta, Anjan ;
Debt, S. K. .
STRUCTURAL ENGINEERING AND MECHANICS, 2007, 26 (04) :459-477
[33]   Wave vibration control of jacket platform by tuned liquid dampers [J].
Sardar, Rajib ;
Chakraborty, Subrata .
OCEAN ENGINEERING, 2022, 247
[34]   Seismic responses of an offshore jacket-type platform incorporated with tuned liquid dampers [J].
Lotfollahi-Yaghin, Mohammad Ali ;
Ahmadi, Hamid ;
Tafakhor, Hassan .
ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (02) :227-238
[35]   Optimum Arrangement of TADAS Dampers for Seismic Drift Control of Buildings Using Accelerated Iterative Methods [J].
Li, Zongjing ;
Wang, Junle ;
Li, Chen ;
Cao, Jing .
BUILDINGS, 2023, 13 (11)
[36]   Seismic Control of SDOF Systems with Nonlinear Eddy Current Dampers [J].
Liang, Longteng ;
Feng, Zhouquan ;
Chen, Zhengqing .
APPLIED SCIENCES-BASEL, 2019, 9 (16)
[37]   Hedge-Algebras-based hybrid control of earthquake-induced buildings using upgraded tuned liquid column dampers [J].
Cao, Huong Quoc ;
Tran, Ngoc-An ;
Bui, Hai -Le .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 182
[38]   Seismic Protection of Existing Buildings with Tuned-Mass Control Systems [J].
Nawrotzki, Peter ;
Popp, Traian ;
Siepe, Daniel .
STRUCTURAL ENGINEERING INTERNATIONAL, 2013, 23 (02) :214-218
[39]   Response Mitigation of Floating Platform by Porous-Media-Tuned Liquid Dampers [J].
Tsao, Wen-Huai ;
Chen, Ying-Chuan ;
Kees, Christopher E. ;
Manuel, Lance .
JOURNAL OF OFFSHORE MECHANICS AND ARCTIC ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (05)
[40]   RESPONSE MITIGATION OF FLOATING PLATFORM BY POROUS-MEDIA TUNED LIQUID DAMPERS [J].
Tsao, Wen-Huai ;
Chen, Ying-Chuan ;
Kees, Christopher E. ;
Manuel, Lance .
PROCEEDINGS OF ASME 2022 41ST INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE & ARCTIC ENGINEERING, OMAE2022, VOL 7, 2022,