Performance evaluation of modified tuned liquid dampers for seismic response control of nonlinear benchmark buildings

被引:0
作者
Daneshmand, A. H. [1 ]
Karamodin, A. [1 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Civil Engn, Mashhad, Iran
关键词
Energy dissipation; Modi ed TunedLiquid Damper(MTLD); Nonlinear benchmarkbuildings; Structural damage; Passive control; SIMULATION;
D O I
10.24200/sci.2023.59989.6548
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Tn this study, the performance of Modified Tuned Liquid Damper (MTLD) is evaluated to control the seismic response of 9- and 20-story nonlinear benchmark buildings. MTLD is a type of Tuned Liquid Damper (TLD) that is equipped with a rotational spring at the base and thus experiences both horizontal and rotational motion with structural vibration. The equations obtained by shallow water wave theory are used to describe the water sloshing in the MTLD tank. The optimal design of main MTLD parameters such as dimensionless rotational stiffness, mass and frequency ratio, and the tank distance from the top of the structure are investigated. Tn addition, the effects of far-field and near-field earthquakes on MTLD performance are discussed and compared with the performance of TLD in detail. The results show that MTLD is somewhat more efficient than TLD both in reducing seismic response and reducing structural damage caused by nonlinear behavior of the structures.
引用
收藏
页码:588 / 602
页数:15
相关论文
共 50 条
  • [21] Experimental comparison of nonlinear damping performance of toroidal and conventional tuned liquid column dampers
    Ding, Hao
    Wang, Jin-Ting
    Lu, Li-Qiao
    Pan, Jian-Wen
    NONLINEAR DYNAMICS, 2021, 104 (04) : 3365 - 3384
  • [22] Optimal Design of Multiple Tuned Liquid Column Dampers for Seismic Vibration Control of MDOF Structures
    Mohebbi, Mohtasham
    Dabbagh, Hamed Rasouli
    Shakeri, Kazem
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2015, 59 (04): : 543 - 558
  • [23] Tuned liquid dampers for controlling earthquake response of structures
    Banerji, P
    Murudi, M
    Shah, AH
    Popplewell, N
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2000, 29 (05) : 587 - 602
  • [24] Development and validation of a nonlinear dynamic model for tuned liquid multiple columns dampers
    Cao, Liang
    Gong, Yongqiang
    Ubertini, Filippo
    Wu, Hao
    Chen, An
    Laflamme, Simon
    JOURNAL OF SOUND AND VIBRATION, 2020, 487
  • [25] Performance-based seismic design of tuned inerter dampers
    Radu, Alin
    Lazar, Irina F.
    Neild, Simon A.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (05)
  • [26] Influence of nonlinear fluid viscous dampers in controlling the seismic response of the base-isolated buildings
    Deringol, Ahmet Hilmi
    Guneyisi, Esra Mete
    STRUCTURES, 2021, 34 : 1923 - 1941
  • [27] Nonlinear Dynamic Analysis of Multi-Sloshing Mode Tuned Liquid Sloshing Dampers Installed in Tall Buildings
    Jeong, U. Y.
    STRUCTURES CONGRESS 2017: BUILDINGS AND SPECIAL STRUCTURES, 2017, : 1 - 12
  • [28] Impact of seismic excitation characteristics on the efficiency of tuned liquid column dampers
    Ali Kavand
    S. Mehdi Zahrai
    EarthquakeEngineeringandEngineeringVibration, 2006, (02) : 235 - 243
  • [29] Impact of seismic excitation characteristics on the efficiency of tuned liquid column dampers
    Kavand A.
    Zahrai S.M.
    Earthquake Engineering and Engineering Vibration, 2006, 5 (2) : 235 - 243
  • [30] Discussion of system intrinsic parameters of tuned mass dampers used for seismic response reduction
    Miranda, Julio C.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2016, 23 (02) : 349 - 368