Performance evaluation of modified tuned liquid dampers for seismic response control of nonlinear benchmark buildings

被引:0
|
作者
Daneshmand, A. H. [1 ]
Karamodin, A. [1 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Civil Engn, Mashhad, Iran
关键词
Energy dissipation; Modi ed TunedLiquid Damper(MTLD); Nonlinear benchmarkbuildings; Structural damage; Passive control; SIMULATION;
D O I
10.24200/sci.2023.59989.6548
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Tn this study, the performance of Modified Tuned Liquid Damper (MTLD) is evaluated to control the seismic response of 9- and 20-story nonlinear benchmark buildings. MTLD is a type of Tuned Liquid Damper (TLD) that is equipped with a rotational spring at the base and thus experiences both horizontal and rotational motion with structural vibration. The equations obtained by shallow water wave theory are used to describe the water sloshing in the MTLD tank. The optimal design of main MTLD parameters such as dimensionless rotational stiffness, mass and frequency ratio, and the tank distance from the top of the structure are investigated. Tn addition, the effects of far-field and near-field earthquakes on MTLD performance are discussed and compared with the performance of TLD in detail. The results show that MTLD is somewhat more efficient than TLD both in reducing seismic response and reducing structural damage caused by nonlinear behavior of the structures.
引用
收藏
页码:588 / 602
页数:15
相关论文
共 50 条
  • [1] Tuned liquid dampers simulation for earthquake response control of buildings
    T. Novo
    H. Varum
    F. Teixeira-Dias
    H. Rodrigues
    M. Falcao Silva
    A. Campos Costa
    L. Guerreiro
    Bulletin of Earthquake Engineering, 2014, 12 : 1007 - 1024
  • [2] Tuned liquid dampers simulation for earthquake response control of buildings
    Novo, T.
    Varum, H.
    Teixeira-Dias, F.
    Rodrigues, H.
    Falcao Silva, M.
    Campos Costa, A.
    Guerreiro, L.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2014, 12 (02) : 1007 - 1024
  • [3] Stochastic seismic performance evaluation of tuned liquid column dampers
    Won, AYJ
    Pires, JA
    Haroun, MA
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1996, 25 (11) : 1259 - 1274
  • [4] Seismic response control with inelastic tuned mass dampers
    Bagheri, Saman
    Rahmani-Dabbagh, Vahid
    ENGINEERING STRUCTURES, 2018, 172 : 712 - 722
  • [5] Seismic performance evaluation of steel frame structures equipped with tuned liquid dampers
    Akbarpoor S.
    Dehghan S.M.
    Hadianfard M.A.
    Asian Journal of Civil Engineering, 2018, 19 (8) : 1037 - 1053
  • [6] Multi-objective optimization and seismic performance verification of multiple tuned impact dampers for nonlinear benchmark building
    Lu, Zheng
    Liu, Xiangqian
    Ma, Naiyin
    Zhou, Mengyao
    STRUCTURES, 2022, 41 : 1672 - 1686
  • [7] Multiple tuned liquid sloshing dampers for across-wind response control of benchmark tall building
    Sameer J. Suthar
    Radhey Shyam Jangid
    Innovative Infrastructure Solutions, 2022, 7
  • [8] Multiple tuned liquid sloshing dampers for across-wind response control of benchmark tall building
    Suthar, Sameer J.
    Jangid, Radhey Shyam
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2022, 7 (01)
  • [9] Performance of tuned liquid dampers
    Tait, M. J.
    Lsyumov, N.
    El Damatty, A. A.
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2008, 134 (05): : 417 - 427
  • [10] On tuned mass dampers for reducing the seismic response of structures
    Miranda, JC
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2005, 34 (07) : 847 - 865