Relaxation-Based Super-Resolution Method in Pulsed Magnetic Particle Imaging

被引:0
|
作者
Li, Lei [1 ,2 ,3 ]
Yan, Haohao [1 ]
Li, Yuge [1 ]
Liao, Yidong [1 ,4 ]
Liu, Yanjun [4 ]
Zhang, Ruili [1 ]
Wang, Zhongliang [1 ]
Feng, Xin [2 ,3 ,5 ]
Tian, Jie [1 ,2 ,3 ,6 ,7 ,8 ]
机构
[1] Xidian Univ, Sch Life Sci & Technol, Xian 710126, Peoples R China
[2] CAS Key Lab Mol Imaging, Beijing 100190, Peoples R China
[3] Beijing Key Lab Mol Imaging, Inst Automat, Beijing 100190, Peoples R China
[4] Beihang Univ, Sch Biol Sci & Med Engn, Beijing 100191, Peoples R China
[5] Univ Chinese Acad Sci, Sch Artificial Intelligence, Beijing 100080, Peoples R China
[6] Beihang Univ, Sch Engn Med, Sch Biol Sci & Med Engn, Key Lab Big Data Based Precis Med, Beijing 100191, Peoples R China
[7] Beihang Univ, Minist Ind & Informat Technol China, Beijing 100191, Peoples R China
[8] Natl Key Lab Kidney Dis, Beijing 100853, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Spatial resolution; Imaging; Mathematical models; Magnetic fields; Superresolution; Image reconstruction; Magnetization; Sensitivity; Molecular imaging; Encoding; Magnetic particle imaging; pulsed excitation; super-resolution; reconstruction; LOW-RANK; RECONSTRUCTION;
D O I
10.1109/TCI.2024.3503364
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spatial resolution is one of the most critical indicators for magnetic particle imaging (MPI). Due to factors such as relaxation effects and suboptimal magnetization response, MPI has not yet reached the promised spatial resolution. Pulsed MPI is a method that enables MPI to achieve the resolution predicted by the Langevin function, which thereby enables larger magnetic particles (MNPs) to enhance resolution. To further exceed this resolution, we propose a relaxation-based super-resolution method which leverages the principle that MNPs at different positions exhibit varying relaxation times due to the different DC fields provided by the gradient field. This principle allows the super-resolution method to extract signals from the center of the field free region (FFR) to enhance spatial resolution. The super-resolution method first truncates the exponential decay signal during the plateau phase of the excitation field. Then, the truncated signals are decomposed based on their relaxation times. Finally, signals from the center position of the FFR are retained, and signals from the periphery of the FFR are discarded. Using this retained signal for reconstruction results in a higher spatial resolution. We validate this method via both simulation and experimental measurements. The results indicate that, compared with sinusoidal MPI and pulsed MPI without super-resolution, the super-resolution method has two-fold improvement in resolution.
引用
收藏
页码:1692 / 1705
页数:14
相关论文
共 50 条
  • [11] OPA-LiDAR Active Optical Synthetic Aperture Super-Resolution Detection Imaging Technology
    Wang, Zihao
    Liu, Yabo
    Yang, Panxiong
    Chen, Zuntian
    Xu, Jiamu
    Liao, Jiali
    Sun, Yanling
    Zhang, Jincheng
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2025, 43 (05) : 2125 - 2131
  • [12] A NOVEL METHOD FOR SUPER-RESOLUTION
    Zhou, Fang-Rong
    Mou, Fan
    Cheng, Huixuan
    Peng, Jing
    Ma, Yi
    Zheng, Ze-Zhong
    Yu, Shi-Jie
    Li, Jiang
    2019 16TH INTERNATIONAL COMPUTER CONFERENCE ON WAVELET ACTIVE MEDIA TECHNOLOGY AND INFORMATION PROCESSING (ICWAMTIP), 2019, : 336 - 339
  • [13] An Effective Method of Image Registration for Super-Resolution
    Pang, Yue
    Gu, Lingjia
    Ren, Ruizhi
    Sun, Jian
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXXVI, 2013, 8856
  • [14] A FOCUSS based super-resolution method for ISAR imaging
    Ping, C
    Jiang, YC
    Xu, RQ
    PROCEEDINGS OF THE 8TH JOINT CONFERENCE ON INFORMATION SCIENCES, VOLS 1-3, 2005, : 574 - 577
  • [15] Optimization-based algorithm for x-ray super-resolution imaging
    Liu, Xin
    Chen, Rongze
    Huang, Jianheng
    Lei, Yaohu
    Yang, Qiang
    Li, Ji
    OPTICAL ENGINEERING, 2022, 61 (04)
  • [16] Infrared chemical imaging: Spatial resolution evaluation and super-resolution concept
    Offroy, Marc
    Roggo, Yves
    Milanfar, Peyman
    Duponchel, Ludovic
    ANALYTICA CHIMICA ACTA, 2010, 674 (02) : 220 - 226
  • [17] Ultrasound Microvascular Imaging Based on Super-Resolution Radial Fluctuations
    Zhang, Jiabin
    Li, Nan
    Dong, Feihong
    Liang, Shuyuan
    Wang, Di
    An, Jian
    Long, Yunfei
    Wang, Yuexiang
    Luo, Yukun
    Zhang, Jue
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (08) : 1507 - 1516
  • [18] Continuous implicit neural representation for arbitrary super-resolution of system matrix in magnetic particle imaging
    Miao, Zhaoji
    Zhang, Liwen
    Tian, Jie
    Yang, Guanyu
    Hui, Hui
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (04)
  • [19] A novel super-resolution imaging method based on TDI CCD charge transfer and random exposure
    Li, Yun-Hui
    Wang, Xiao-Dong
    Wang, Zhi
    OPTICS COMMUNICATIONS, 2018, 426 : 170 - 181
  • [20] Super-resolution in magnetic resonance imaging: A review
    Van Reeth, Eric
    Tham, Ivan W. K.
    Tan, Cher Heng
    Poh, Chueh Loo
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2012, 40A (06) : 306 - 325