Relaxation-Based Super-Resolution Method in Pulsed Magnetic Particle Imaging

被引:0
|
作者
Li, Lei [1 ,2 ,3 ]
Yan, Haohao [1 ]
Li, Yuge [1 ]
Liao, Yidong [1 ,4 ]
Liu, Yanjun [4 ]
Zhang, Ruili [1 ]
Wang, Zhongliang [1 ]
Feng, Xin [2 ,3 ,5 ]
Tian, Jie [1 ,2 ,3 ,6 ,7 ,8 ]
机构
[1] Xidian Univ, Sch Life Sci & Technol, Xian 710126, Peoples R China
[2] CAS Key Lab Mol Imaging, Beijing 100190, Peoples R China
[3] Beijing Key Lab Mol Imaging, Inst Automat, Beijing 100190, Peoples R China
[4] Beihang Univ, Sch Biol Sci & Med Engn, Beijing 100191, Peoples R China
[5] Univ Chinese Acad Sci, Sch Artificial Intelligence, Beijing 100080, Peoples R China
[6] Beihang Univ, Sch Engn Med, Sch Biol Sci & Med Engn, Key Lab Big Data Based Precis Med, Beijing 100191, Peoples R China
[7] Beihang Univ, Minist Ind & Informat Technol China, Beijing 100191, Peoples R China
[8] Natl Key Lab Kidney Dis, Beijing 100853, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Spatial resolution; Imaging; Mathematical models; Magnetic fields; Superresolution; Image reconstruction; Magnetization; Sensitivity; Molecular imaging; Encoding; Magnetic particle imaging; pulsed excitation; super-resolution; reconstruction; LOW-RANK; RECONSTRUCTION;
D O I
10.1109/TCI.2024.3503364
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spatial resolution is one of the most critical indicators for magnetic particle imaging (MPI). Due to factors such as relaxation effects and suboptimal magnetization response, MPI has not yet reached the promised spatial resolution. Pulsed MPI is a method that enables MPI to achieve the resolution predicted by the Langevin function, which thereby enables larger magnetic particles (MNPs) to enhance resolution. To further exceed this resolution, we propose a relaxation-based super-resolution method which leverages the principle that MNPs at different positions exhibit varying relaxation times due to the different DC fields provided by the gradient field. This principle allows the super-resolution method to extract signals from the center of the field free region (FFR) to enhance spatial resolution. The super-resolution method first truncates the exponential decay signal during the plateau phase of the excitation field. Then, the truncated signals are decomposed based on their relaxation times. Finally, signals from the center position of the FFR are retained, and signals from the periphery of the FFR are discarded. Using this retained signal for reconstruction results in a higher spatial resolution. We validate this method via both simulation and experimental measurements. The results indicate that, compared with sinusoidal MPI and pulsed MPI without super-resolution, the super-resolution method has two-fold improvement in resolution.
引用
收藏
页码:1692 / 1705
页数:14
相关论文
共 50 条
  • [1] Super-Resolution Imaging Method for Synthetic Aperture Interferometric Radiometer Based on Spectral Extrapolation
    Chen, Jianfei
    Yu, Jiahao
    Ruan, Yujie
    Zhang, Chenggong
    Zheng, Ziang
    Cai, Fuxin
    Zhu, Shujin
    Liu, Leilei
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2025, 22
  • [2] Rapid TAURUS for Relaxation-Based Color Magnetic Particle Imaging
    Arslan, M. Tunc
    Ozaslan, A. Alper
    Kurt, Semih
    Muslu, Yavuz
    Saritas, Emine Ulku
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (12) : 3774 - 3786
  • [3] A CNN Based Super-Resolution Technique for Magnetic Particle Imaging System Matrix
    Askin, Baris
    Gungor, Alper
    Soydan, Damla Alptekin
    Top, Can Baris
    Cukur, Tolga
    29TH IEEE CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS (SIU 2021), 2021,
  • [4] TranSMS: Transformers for Super-Resolution Calibration in Magnetic Particle Imaging
    Gungor, Alper
    Askin, Baris
    Soydan, Damla Alptekin
    Saritas, Emine Ulku
    Top, Can Baris
    Cukur, Tolga
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (12) : 3562 - 3574
  • [5] A Super-Resolution Imaging Method Based on a Left-Handed Material and a Diffusion Model
    Zhang, Qianqian
    Yin, Chengyou
    Li, Anqi
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2025, 73 (05) : 3035 - 3046
  • [6] Optoacoustic imaging quality enhancement based on geometrical super-resolution method
    He, Hailong
    Mandal, Subhamoy
    Buehler, Andreas
    Dean-Ben, X. Luis
    Razansky, Daniel
    Ntziachristos, Vasilis
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2016, 2016, 9708
  • [7] Relaxation-based viscosity mapping for magnetic particle imaging
    Utkur, M.
    Muslu, Y.
    Saritas, E. U.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09) : 3422 - 3439
  • [8] Super-Resolution in Medical Imaging
    Greenspan, Hayit
    COMPUTER JOURNAL, 2009, 52 (01) : 43 - 63
  • [9] Calibration-Free Relaxation-Based Multi-Color Magnetic Particle Imaging
    Muslu, Yavuz
    Utkur, Mustafa
    Demirel, Omer Burak
    Saritas, Emine Ulku
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (08) : 1920 - 1931
  • [10] First Superferromagnetic Remanence Characterization and Scan Optimization for Super-Resolution Magnetic Particle Imaging
    Fung, K. L. Barry
    Colson, Caylin
    Bryan, Jacob
    Saayujya, Chinmoy
    Mokkarala-Lopez, Javier
    Hartley, Allison
    Yousuf, Khadija
    Kuo, Renesmee
    Lu, Yao
    Fellows, Benjamin D.
    Chandrasekharan, Prashant
    Conolly, Steven M.
    NANO LETTERS, 2023, 23 (05) : 1717 - 1725