Research on the attenuation of internal pressure in the large-span cylindrical roof building with a dominant gable opening

被引:0
|
作者
Ge, Yuhang [1 ]
Sun, Ying [1 ,2 ]
Cao, Zhenggang [3 ]
Zhu, Qiming [3 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[3] Harbin Inst Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Minist Ind & Informat Technol, Harbin 150090, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
NET PRESSURES; WIND LOADS;
D O I
10.1063/5.0220765
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The internal to external pressure ratio in a large-span cylindrical roof building with a dominant gable opening fluctuates dramatically between 0 and 1, significantly impacted by the attenuation of internal pressure. Current theories usually assume this ratio equal to 1 and overlook the attenuation effect. This study investigates four cylindrical roof models with varying opening areas, scale ratios, and wind speeds by wind tunnel tests. It analyzes ratios of mean ((C) over bar (pi)/(C) over bar (pe)), fluctuating (sigma(pi)/sigma(pe)), and peak ((C) over cap (pi)/(C) over cap (pe)) internal to external pressure to pinpoint factors affecting the internal pressure attenuation. The results highlight that the most pronounced internal pressure attenuation is at the sideward opening. The vortex shedding around the opening is induced by the wind direction, scale ratio, and wind speed. The attenuation effect decreases with lower frequencies of periodic vortex shedding. This effect generally vanishes when the windward or leeward opening ratio (A(1.5)/V-0) exceeds 0.57%. Empirical design formulas are proposed to predict ratios of internal to external pressure considering the attenuation effect. The inertia (C-I) and loss coefficients (C-L) affected by the internal pressure attenuation are analyzed to estimate the air slug inertia and damping through the opening. A governing equation, incorporating reduction coefficients ((C) over tilde (eddy), (C) over tilde (eddy)) from empirical design formulas, is applied to precisely compute the attenuated internal pressure in the large-span cylindrical roof building with a dominant gable opening for engineering risk assessment.
引用
收藏
页数:19
相关论文
共 48 条
  • [21] A fast partition method for wind pressure coefficient of large-span roof based on modified GK clustering
    Chen, Fubin
    Zhan, Zhuoyu
    Zhou, Jinfang
    Shu, Zhenru
    Li, Qiusheng
    STRUCTURES, 2021, 30 : 518 - 530
  • [22] Wind pressure features of large-span flat roof in different wind fields induced by conical vortex
    Ye, Jihong
    Dong, Xin
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2015, 38 (08) : 975 - 990
  • [23] Research on the method for selecting dominant modes of wind-induced response for large-span roofs
    Li, Yu-Xue
    Yang, Qing-Shan
    Tian, Yu-Ji
    Jisuan Lixue Xuebao/Chinese Journal of Computational Mechanics, 2010, 27 (06): : 1049 - 1054
  • [24] Experimental Wind Pressure Distribution on Large-Span Three-Centered Cylindrical Reticulated Shell
    Zhang Q.
    Ma W.
    Wang Q.
    Fang P.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2019, 39 (04): : 733 - 738
  • [25] Research on the law of instability and caving for large-span cut-hole roof with thin bedrock in depth
    Jia, Housheng
    Ma, Nianjie
    Zhao, Xidong
    Zhang, Shengkai
    Caikuang yu Anquan Gongcheng Xuebao/Journal of Mining and Safety Engineering, 2014, 31 (05): : 702 - 708
  • [26] Wind resistance research and wind tunnel test of large-span roof based on Yancheng Financial Center
    Liu, Fei
    Zhang, Zhiqiang
    Fang, Zifen
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 1036 - 1040
  • [27] Experimental research of pipe-roof pre-supporting technology for the shallow large-span tunnel
    Tan, Zhongsheng
    Sun, Xiaojing
    Ma, Dong
    Ma, Yongchang
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2015, 48 : 429 - 434
  • [28] Internal pressure in a building with a single dominant opening: An experimental and numerical case study
    Guha, T.K.
    Sharma, R.N.
    Richards, R.J.
    Journal of Structural Engineering (India), 2014, 41 (01): : 59 - 67
  • [29] NON-STATIONARY STATISTICS OF NON-GAUSSIAN WIND PRESSURE PROCESSES ON A LARGE-SPAN LONG ROOF
    Huang, M. F.
    Feng, He
    Huang, Song
    Lou, Wenjuan
    Fundamental Research in Structural Engineering: Retrospective and Prospective, Vols 1 and 2, 2016, : 833 - 840
  • [30] Internal pressure dynamics of a leaky and quasi-statically flexible building with a dominant opening
    Guha, T. K.
    Sharma, R. N.
    Richards, P. J.
    WIND AND STRUCTURES, 2013, 16 (01) : 61 - 91