Calculation of short-circuit current of DFIG with the considering of crowbar resistance

被引:0
|
作者
Pan W. [1 ]
Yang G. [1 ]
Liu M. [1 ]
Pan X. [1 ]
Yang J. [2 ]
Sun K. [2 ]
Yang C. [3 ]
机构
[1] College of Energy and Electrical Engineering, Hohai University, Nanjing, 210098, Jiangsu Province
[2] Power China Huadong Engineering Corporation Limited, Hangzhou, 311122, Zhejiang Province
[3] State Grid Yangzhou Power Supply Company, Yangzhou, 225000, Jiangsu Province
基金
中国国家自然科学基金;
关键词
Crowbar resistance; Doubly fed induction generator; PSCAD/EMTDC; Three-phase short-circuit current; Voltage dip;
D O I
10.13334/j.0258-8013.pcsee.152124
中图分类号
学科分类号
摘要
Crowbar protection is the main protection device of most double fed induction generator(DFIG) at present. The existence of Crowbar resistance has an important influence on the transient process of doubly fed induction generator. So the Crowbar resistance element should be considered in the calculation of three-phase short-circuit current of doubly fed induction generator. The transient equivalent circuit of doubly fed induction generation system with Crowbar resistance was built, the influence of stator side equivalent impedance on the transient process was analyzed, The expression of stator side transient equivalent impedance was derived, and on the basis of this, the expression of the maximum value and the effective value of the periodic component of the three-phase short-circuit current of the doubly fed wind generator was derived. The effects of different Crowbar resistance values on the calculation of three-phase short circuit current were also given. At last, the maximum of three phase short circuit current and the effective value of the periodic component were verified by PSCAD/EMTDC simulation. The effective value and the maximum value of three-phase short current of doubly fed induction generator are accurate and convenient, which is of great significance to the electrical safety design of the wind farm. © 2016 Chin. Soc. for Elec. Eng.
引用
收藏
页码:3629 / 3634
页数:5
相关论文
共 15 条
  • [1] Lu Z.Y., Li W.H., Xie B.C., Et al., Study on China's wind power development path - based on the target for 2030, Renewable and Sustainable Energy Review, 51, 11, pp. 197-208, (2015)
  • [2] Sun S., Liu F., Xue S., Et al., Review on wind power development in China: Current situation and improvement strategies to realize future development, Renewable and Sustainable Energy Reviews, 45, 5, pp. 589-599, (2015)
  • [3] Rahimi M., Parniani M., Grid-fault ride-through analysis and control of wind turbines with doubly fed induction generators, Electric Power System Research, 80, 2, pp. 184-195, (2010)
  • [4] Li W., Tang G., Kang Y., Et al., Starting up and integration control of doubly-fed variable-speed constant-frequency wind power generator based on VSC-HVDC, Proceedings of the CSEE, 34, 12, pp. 1864-1873, (2014)
  • [5] Nian H., Cheng P., He Y., Review on operation techniques for DFIG-based wind energy conversion systems under network faults, Proceedings of the CSEE, 35, 16, pp. 4184-4197, (2015)
  • [6] Ye X., Lu Z., Qiao Y., Et al., A primary analysis on mechanism of large scale cascading trip-off of wind turbine generators, Automation of Electric Power Systems, 36, 8, pp. 11-17, (2012)
  • [7] He Y., Hu J., Several hot-spot issues associated with the grid-connected operations of wind-turbine driven doubly fed induction generators, Proceeding of the CSEE, 32, 27, pp. 1-15, (2012)
  • [8] Fan G., Ye T., Xin Y., Et al., Problems and measures of power grid accommodating large scale wind power, Proceeding of the CSEE, 30, 25, pp. 1-9, (2010)
  • [9] GB/Z 19963-2005 Technical rule for connecting wind farm to power network, (2006)
  • [10] Akhmatov V., Induction Generators for Wind Power, pp. 156-183, (2005)