Smart early diagnosis of acute myocardial infarction: a ZIF-based nanofluorescence lateral flow immunoassay for point-of-care detection of cTnI

被引:0
|
作者
Mirzaeizadeh, Zahra [1 ]
Sadrabadi, Emadoddin Amin [1 ]
Naseri, Neda [1 ]
Golmohammadi, Hamed [2 ]
Omidfar, Kobra [1 ,3 ]
机构
[1] Univ Tehran Med Sci, Endocrinol & Metab Mol Cellular Sci Inst, Biosensor Res Ctr, POB 14395-1179, Tehran, Iran
[2] Chem & Chem Engn Res Ctr Iran, Nanosensor Bioplatforms Lab, Tehran 14335186, Iran
[3] Univ Tehran Med Sci, Endocrinol & Metab Res Inst, Endocrinol & Metab Res Ctr, Tehran, Iran
来源
MATERIALS ADVANCES | 2025年 / 6卷 / 02期
关键词
METAL-ORGANIC FRAMEWORKS; ACID-BINDING PROTEIN; TROPONIN-I; ASSAY;
D O I
10.1039/d4ma01000k
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Despite significant progress in the diagnosis of acute myocardial infarction (AMI), its morbidity and mortality rates are still high, indicating the necessity of developing easy-to-use diagnostic tests with timely and reliable point-of-care (POC) detection capability. Aiming to address this need, we introduce here for the first time the development of a fluorescence lateral flow immunoassay (LFIA) based on antibody labeled ZIF-8@BSA Au/Ag nanoclusters for the quantitative detection of cardiac troponin I (cTnI) as the major biomarker of AMI. A portable IoT-enabled optoelectronic reader was also fabricated to quantify the fluorescence signals of the developed LFIA, enabling easy, precise, and smart on-site quantitative analysis of cTnI. The developed smart LFIA demonstrated desirable assay performance for cTn1 in a linear concentration range of 10 pg mL-1 to 150 pg mL-1 with an appropriate sensitivity (with a detection limit of 9 pg mL-1) compared to the enzyme-linked immunosorbent assay (ELISA) and other reported assays. The fascinating results of our developed smart LFIA for easy, rapid (similar to 10 min), and highly sensitive and specific detection of cTnI in serum and whole blood samples make it a very promising biosensor capable of being exploited for smart, reliable, and early diagnosis of AMI at the POC.
引用
收藏
页码:839 / 848
页数:10
相关论文
共 17 条
  • [1] Upconversion nanoparticles-based lateral flow immunoassay for point-of-care diagnosis of periodontitis
    He, Wanghong
    You, Minli
    Li, Zedong
    Cao, Lei
    Xu, Feng
    Li, Fei
    Li, Ang
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 334
  • [2] Development of a Point-of-Care SPR Sensor for the Diagnosis of Acute Myocardial Infarction
    Choudhary, Sunil
    Altintas, Zeynep
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [3] Advances in nanoparticle-based lateral flow immunoassay for point-of-care testing
    Lou, Doudou
    Fan, Lin
    Jiang, Tao
    Zhang, Yu
    VIEW, 2022, 3 (01)
  • [4] SERS Based Lateral Flow Immunoassay for Point-of-Care Detection of SARS-CoV-2 in Clinical Samples
    Yadav, Shalu
    Sadique, Mohd Abubakar
    Ranjan, Pushpesh
    Kumar, Neeraj
    Singhal, Ayushi
    Srivastava, Avanish K.
    Khan, Raju
    ACS APPLIED BIO MATERIALS, 2021, 4 (04): : 2974 - 2995
  • [5] An enhanced centrifugation-assisted lateral flow immunoassay for the point-of-care detection of protein biomarkers
    Shen, Minjie
    Li, Nan
    Lu, Ying
    Cheng, Jing
    Xu, Youchun
    LAB ON A CHIP, 2020, 20 (15) : 2626 - 2634
  • [6] Tapered lateral flow immunoassay based point-of-care diagnostic device for ultrasensitive colorimetric detection of dengue NS1
    Kumar, Sanjay
    Bhushan, Pulak
    Krishna, Vinay
    Bhattacharya, Shantanu
    BIOMICROFLUIDICS, 2018, 12 (03):
  • [7] A gold nanoparticle-based lateral flow immunoassay for atrazine point-of-care detection using a handhold scanning device as reader
    Sun, Tieqiang
    Xu, Zehua
    Yuan, Shuai
    Liu, Xiao
    Chen, Zongfen
    Han, Zhenyu
    Liu, Wentao
    Fan, Longxing
    Yang, Han
    Qie, Zhiwei
    Ning, Baoan
    MICROCHIMICA ACTA, 2022, 189 (04)
  • [8] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [9] Fluorescence lateral flow immunoassay based point-of-care nanodiagnostics for orthopedic implant-associated infection
    Borse, Vivek
    Srivastava, Rohit
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 280 : 24 - 33
  • [10] POINT-OF-CARE TEST FOR C-REACTIVE PROTEIN BY A FLUORESCENCE-BASED LATERAL FLOW IMMUNOASSAY
    Gu, Yongbin
    Yang, Yongliang
    Zhang, Jing
    Ge, ShengXiang
    Tang, Zhanghong
    Qiu, Xianbo
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2014, 42 (06) : 635 - 645