Automatic Image Registration Provides Superior Accuracy Compared with Surface Matching in Cranial Navigation

被引:0
|
作者
Frisk, Henrik [1 ,2 ]
Jensdottir, Margret [1 ,2 ]
Coronado, Luisa [3 ]
Conrad, Markus [3 ]
Hager, Susanne [3 ]
Arvidsson, Lisa [1 ,2 ]
Bartek Jr, Jiri [1 ,2 ]
Burstroem, Gustav [1 ,2 ]
El-Hajj, Victor Gabriel [1 ]
Edstroem, Erik [1 ,4 ]
Elmi-Terander, Adrian [1 ,4 ,5 ]
Persson, Oscar [1 ,2 ]
机构
[1] Karolinska Inst, Dept Clin Neurosci, SE-17177 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Neurosurg, SE-17176 Stockholm, Sweden
[3] Brainlab AG, Clin Affairs, D-81829 Munich, Germany
[4] Lowenstromska Hosp, Capio Spine Ctr Stockholm, SE-19489 Upplands Vasby, Sweden
[5] Uppsala Univ, Dept Surg Sci, SE-75236 Uppsala, Sweden
关键词
patient tracking; reference frame; surface matching; CBCT; neurosurgery; surgical navigation; automatic image registration; accuracy; GUIDED NEUROSURGERY; PATIENT;
D O I
10.3390/s24227341
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Objective: The precision of neuronavigation systems relies on the correct registration of the patient's position in space and aligning it with radiological 3D imaging data. Registration is usually performed by the acquisition of anatomical landmarks or surface matching based on facial features. Another possibility is automatic image registration using intraoperative imaging. This could provide better accuracy, especially in rotated or prone positions where the other methods may be difficult to perform. The aim of this study was to validate automatic image registration (AIR) using intraoperative cone-beam computed tomography (CBCT) for cranial neurosurgical procedures and compare the registration accuracy to the traditional surface matching (SM) registration method based on preoperative MRI. The preservation of navigation accuracy throughout the surgery was also investigated. Methods: Adult patients undergoing intracranial tumor surgery were enrolled after consent. A standard SM registration was performed, and reference points were acquired. An AIR was then performed, and the same reference points were acquired again. Accuracy was calculated based on the referenced and acquired coordinates of the points for each registration method. The reference points were acquired before and after draping and at the end of the procedure to assess the persistency of accuracy. Results: In total, 22 patients were included. The mean accuracy was 6.6 +/- 3.1 mm for SM registration and 1.0 +/- 0.3 mm for AIR. The AIR was superior to the SM registration (p < 0.0001), with a mean improvement in accuracy of 5.58 mm (3.71-7.44 mm 99% CI). The mean accuracy for the AIR registration pre-drape was 1.0 +/- 0.3 mm. The corresponding accuracies post-drape and post-resection were 2.9 +/- 4.6 mm and 4.1 +/- 4.9 mm, respectively. Although a loss of accuracy was identified between the preoperative and end-of-procedure measurements, there was no statistically significant decline during surgery. Conclusions: AIR for cranial neuronavigation consistently delivered greater accuracy than SM and should be considered the new gold standard for patient registration in cranial neuronavigation. If intraoperative imaging is a limited resource, AIR should be prioritized in rotated or prone position procedures, where the benefits are the greatest.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Surface matching for high-accuracy registration of the lateral skull base
    Chaozheng Zhou
    Lukas Anschuetz
    Stefan Weder
    Le Xie
    Marco Caversaccio
    Stefan Weber
    Tom Williamson
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 2097 - 2103
  • [22] Estimation of the accuracy of a surface matching technique for registration of EEG and MRI data
    Huppertz, HJ
    Otte, M
    Grimm, C
    Kristeva-Feige, R
    Mergner, T
    Lücking, CH
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (05): : 409 - 415
  • [23] Surface matching for high-accuracy registration of the lateral skull base
    Zhou, Chaozheng
    Anschuetz, Lukas
    Weder, Stefan
    Xie, Le
    Caversaccio, Marco
    Weber, Stefan
    Williamson, Tom
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (11) : 2097 - 2103
  • [24] Automatic UAV Image Geo-Registration by Matching UAV Images to Georeferenced Image Data
    Zhuo, Xiangyu
    Koch, Tobias
    Kurz, Franz
    Fraundorfer, Friedrich
    Reinartz, Peter
    REMOTE SENSING, 2017, 9 (04)
  • [25] Matching Accuracy Comparison Between Five Different Deformable Image Registration Algorithms
    Horita, M.
    Hayashi, N.
    Kato, I.
    Yamanaka, D.
    Yasui, K.
    Takemura, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E734 - E734
  • [26] Automatic registration of multi-source imagery based on global image matching
    Zhang, ZX
    Zhang, JQ
    Liao, MS
    Zhang, L
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 2000, 66 (05): : 625 - 629
  • [27] An Accurate Feature Point Matching Algorithm for Automatic Remote Sensing Image Registration
    Wu, Guan-Long
    Chang, Herng-Hua
    2017 INTERNATIONAL CONFERENCE ON DIGITAL IMAGE COMPUTING - TECHNIQUES AND APPLICATIONS (DICTA), 2017, : 164 - 171
  • [28] Noctopus: a novel device and method for patient registration and navigation in image-guided cranial surgery
    Oezbek, Yusuf
    Bardosi, Zoltan
    Freysinger, Wolfgang
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (12) : 2371 - 2380
  • [29] ENHANCEMENT OF THE VERTICAL ACCURACY OF LIDAR DATA WITH THE USE OF AUTOMATIC IMAGE MATCHING
    Dominik, Wojciech
    GEOCONFERENCE ON INFORMATICS, GEOINFORMATICS AND REMOTE SENSING, VOL III, 2014, : 161 - 168
  • [30] Delayed FDG PET Provides Superior Glioblastoma Conspicuity Compared to Conventional Image Timing
    Johnson, Jason Michael
    Chen, Melissa M.
    Rohren, Eric M.
    Prabhu, Sujit
    Chasen, Beth
    Mawlawi, Osama
    Liu, Ho-Ling
    Gule-Monroe, Maria Kristine
    FRONTIERS IN NEUROLOGY, 2021, 12