Automatic Image Registration Provides Superior Accuracy Compared with Surface Matching in Cranial Navigation

被引:0
|
作者
Frisk, Henrik [1 ,2 ]
Jensdottir, Margret [1 ,2 ]
Coronado, Luisa [3 ]
Conrad, Markus [3 ]
Hager, Susanne [3 ]
Arvidsson, Lisa [1 ,2 ]
Bartek Jr, Jiri [1 ,2 ]
Burstroem, Gustav [1 ,2 ]
El-Hajj, Victor Gabriel [1 ]
Edstroem, Erik [1 ,4 ]
Elmi-Terander, Adrian [1 ,4 ,5 ]
Persson, Oscar [1 ,2 ]
机构
[1] Karolinska Inst, Dept Clin Neurosci, SE-17177 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Neurosurg, SE-17176 Stockholm, Sweden
[3] Brainlab AG, Clin Affairs, D-81829 Munich, Germany
[4] Lowenstromska Hosp, Capio Spine Ctr Stockholm, SE-19489 Upplands Vasby, Sweden
[5] Uppsala Univ, Dept Surg Sci, SE-75236 Uppsala, Sweden
关键词
patient tracking; reference frame; surface matching; CBCT; neurosurgery; surgical navigation; automatic image registration; accuracy; GUIDED NEUROSURGERY; PATIENT;
D O I
10.3390/s24227341
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Objective: The precision of neuronavigation systems relies on the correct registration of the patient's position in space and aligning it with radiological 3D imaging data. Registration is usually performed by the acquisition of anatomical landmarks or surface matching based on facial features. Another possibility is automatic image registration using intraoperative imaging. This could provide better accuracy, especially in rotated or prone positions where the other methods may be difficult to perform. The aim of this study was to validate automatic image registration (AIR) using intraoperative cone-beam computed tomography (CBCT) for cranial neurosurgical procedures and compare the registration accuracy to the traditional surface matching (SM) registration method based on preoperative MRI. The preservation of navigation accuracy throughout the surgery was also investigated. Methods: Adult patients undergoing intracranial tumor surgery were enrolled after consent. A standard SM registration was performed, and reference points were acquired. An AIR was then performed, and the same reference points were acquired again. Accuracy was calculated based on the referenced and acquired coordinates of the points for each registration method. The reference points were acquired before and after draping and at the end of the procedure to assess the persistency of accuracy. Results: In total, 22 patients were included. The mean accuracy was 6.6 +/- 3.1 mm for SM registration and 1.0 +/- 0.3 mm for AIR. The AIR was superior to the SM registration (p < 0.0001), with a mean improvement in accuracy of 5.58 mm (3.71-7.44 mm 99% CI). The mean accuracy for the AIR registration pre-drape was 1.0 +/- 0.3 mm. The corresponding accuracies post-drape and post-resection were 2.9 +/- 4.6 mm and 4.1 +/- 4.9 mm, respectively. Although a loss of accuracy was identified between the preoperative and end-of-procedure measurements, there was no statistically significant decline during surgery. Conclusions: AIR for cranial neuronavigation consistently delivered greater accuracy than SM and should be considered the new gold standard for patient registration in cranial neuronavigation. If intraoperative imaging is a limited resource, AIR should be prioritized in rotated or prone position procedures, where the benefits are the greatest.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Automatic image registration on intraoperative CBCT compared to Surface Matching registration on preoperative CT for spinal navigation: accuracy and workflow
    Frisk, Henrik
    Burstrom, Gustav
    Persson, Oscar
    El-Hajj, Victor Gabriel
    Coronado, Luisa
    Hager, Susanne
    Edstrom, Erik
    Elmi-Terander, Adrian
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (04) : 665 - 675
  • [2] Automatic image registration on intraoperative CBCT compared to Surface Matching registration on preoperative CT for spinal navigation: accuracy and workflow
    Henrik Frisk
    Gustav Burström
    Oscar Persson
    Victor Gabriel El-Hajj
    Luisa Coronado
    Susanne Hager
    Erik Edström
    Adrian Elmi-Terander
    International Journal of Computer Assisted Radiology and Surgery, 2024, 19 : 665 - 675
  • [3] Current accuracy of surface matching compared to adhesive markers in patient-to-image registration
    Mongen, Mireli A.
    Willems, Peter W. A.
    ACTA NEUROCHIRURGICA, 2019, 161 (05) : 865 - 870
  • [4] Current accuracy of surface matching compared to adhesive markers in patient-to-image registration
    Mireli A. Mongen
    Peter W. A. Willems
    Acta Neurochirurgica, 2019, 161 : 865 - 870
  • [5] Automatic satellite image registration based on intensity matching
    Yao, JC
    Chern, CT
    Hwang, YC
    Adrian, YCL
    IGARSS 2001: SCANNING THE PRESENT AND RESOLVING THE FUTURE, VOLS 1-7, PROCEEDINGS, 2001, : 3297 - 3299
  • [6] A rapid and automatic image registration algorithm with subpixel accuracy
    Althof, RJ
    Wind, MGJ
    Dobbins, JT
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (03) : 308 - 316
  • [7] Rapid and automatic image registration algorithm with subpixel accuracy
    Althof, R.J.
    Wind, M.G.J.
    Dobbins, J.T.
    1997, IEEE, Piscataway, NJ, United States (16)
  • [8] Navigation accuracy after automatic-and hybrid-surface registration in sinus and skull base surgery
    Grauvogel, Tanja Daniela
    Engelskirchen, Paul
    Semper-Hogg, Wiebke
    Grauvogel, Juergen
    Laszig, Roland
    PLOS ONE, 2017, 12 (07):
  • [9] Automatic, high-accuracy image registration in confocal microscopy
    Liu, Jian
    Li, Yong
    Wang, Weibo
    Wang, Yuhang
    Zhang, He
    Tan, Jiubin
    APPLIED OPTICS, 2017, 56 (32) : 8924 - 8930
  • [10] A novel metric for automatic assessment of deformable image registration accuracy
    Brock, K
    Moseley, J
    Jaffray, D
    MEDICAL PHYSICS, 2005, 32 (06) : 1942 - 1942