Numerical Simulation Study on the Stable Combustion of a 660 MW Supercritical Unit Boiler at Ultra-Low Load

被引:0
|
作者
Yang, Kaiyu [1 ]
Li, Zhengxin [2 ]
Cao, Xinsheng [1 ]
Du, Tielin [2 ]
Liu, Lang [2 ]
机构
[1] Power China Jiangxi Elect Power Construction Co Lt, 69 Guangzhou Rd, Nanchang 330001, Peoples R China
[2] Chongqing Univ, Sch Energy & Power Engn, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ, Chongqing 400030, Peoples R China
基金
中国博士后科学基金;
关键词
boiler operation at ultra-low load; stable combustion; low pollutant emission; numerical simulation; UTILITY BOILER; COAL;
D O I
10.3390/pr12112573
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To investigate the safe, stable, and economically viable operation of a boiler under ultra-low-load conditions during the deep peaking process of coal-fired units, a numerical simulation study was conducted on a 660 MW front- and rear-wall hedge cyclone burner boiler. The current research on low load conditions is limited to achieving stable combustion by adjusting the operating parameters, and few effective boiler operating parameter predictions are given for very low-load conditions, i.e., below 20%. Various burner operation modes under ultra-low load conditions were analyzed using computational fluid dynamics (CFDs) methods; this operation was successfully tested with six types of pulverized coal combustion in this paper, and fitting models for outlet flue gas temperature and NOx emissions were derived based on the combustion characteristics of different types of pulverized coal. The results indicate that under 20% ultra-low-load conditions, the use of lower burners leads to a uniform temperature distribution within the furnace, achieving a minimum NOx emission of 112 ppm and a flue gas temperature of 743 K. Coal type 3, with the highest carbon content and a calorific value of 22,440 kJ/kg, has the highest average section temperature of 1435.76 K. In contrast, coal type 1 has a higher nitrogen content, with a maximum cross-sectional average NOx concentration of 865.90 ppm and an exit NOx emission concentration of 800 ppm. The overall lower NOx emissions of coal type 3 are primarily attributed to its reduced nitrogen content and increased oxygen content, which enhance pulverized coal combustion and suppress NOx formation. The fitting models accurately capture the influence of pulverized coal composition on outlet flue gas temperature and NOx emissions. This control strategy can be extended to the stable combustion of many kinds of coal. For validation, the fitting error bar for the predicted outlet flue gas temperature based on the elemental composition of coal type 6 was 8.09%, whereas the fitting error bar for the outlet NOx emissions was only 1.45%.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Numerical Simulation of Combustion in 660 MW Tangentially Fired Pulverized Coal Boiler on Ultra-Low Load Operation
    Jing, Xuehui
    Guo, Junchen
    Wang, Zhiyun
    FRONTIERS IN HEAT AND MASS TRANSFER, 2024, 22 (03): : 919 - 937
  • [2] Numerical simulation and optimization on stable combustion of a 1 000 MW ultra supercritical unit swirl combustion boiler
    Liu, Jianquan
    Sun, Baomin
    Zhang, Guangcai
    Bai, Tao
    Shou, Bing
    Hu, Yongsheng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2012, 32 (08): : 19 - 27
  • [3] Study on ultra-low NOX emission technology of 660 MW ultra-supercritical circulating fluidized bed boiler
    Xin, Shengwei
    Li, Yingping
    Zhang, Peng
    Hu, Changhua
    Wang, Hu
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [4] Thermodynamic analysis of a 660 MW ultra-supercritical CFB boiler unit
    Zhu, Shahong
    Zhang, Man
    Huang, Yiqun
    Wu, Yuxin
    Yang, Hairui
    Lyu, Junfu
    Gao, Xinyu
    Wang, Fengjun
    Yue, Guangxi
    ENERGY, 2019, 173 : 352 - 363
  • [5] Investigations of Combustion Stability in a 660 MW Supercritical W-Flame Boiler Under Low Load
    Ma, Da-Fu
    He, Xiang
    Lü, Wei-Zhi
    Zhang, Jian
    Zhang, Shou-Yu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (01): : 259 - 266
  • [6] Simulation of material balance in a 660 MW ultra-supercritical CFB boiler
    Chen L.
    Tao X.
    Zhang M.
    Gao X.
    Zhao K.
    Zhang S.
    Yang H.
    Lü J.
    Meitan Xuebao/Journal of the China Coal Society, 2020, 45 (11): : 3913 - 3920
  • [7] Numerical Simulation of Combustion Processes in an ultra-supercritical Boiler
    Zeng Ling-da
    Chen Qi-juan
    Zhao Xuan
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [8] Modeling and Simulation for Boiler Combustion Control System of 1000MW Ultra-Supercritical Unit
    Hou Guolian
    Jiang Pengcheng
    Zheng Xiaobin
    Zhang Jianhua
    26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 4042 - 4047
  • [9] Numerical Simulation Study on Retrofit of Low NOx Burner for 1000MW Ultra-supercritical Boiler
    Guan X.
    Li Y.
    Zhu Q.
    Guan M.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (08): : 2376 - 2383
  • [10] Numerical Simulation of Hydrogen-Coal Blending Combustion in a 660 MW Tangential Boiler
    Dong, Lijiang
    Huang, Shangwen
    Qian, Baiyun
    Wang, Kaike
    Gao, Ning
    Lin, Xiang
    Shi, Zeqi
    Lu, Hao
    PROCESSES, 2024, 12 (02)