Primary frequency regulation strategy for doubly-fed induction generators based on virtual inertia

被引:0
作者
Zhao, Jingwei [1 ]
Dou, Zhenhai [1 ]
机构
[1] Shandong University of Technology, Zibo
关键词
Doubly-fed induction generator; Frequency regulation; Virtual inertia;
D O I
10.1051/ijmqe/2024018
中图分类号
学科分类号
摘要
With the continuous increase of wind power generation capacity, the necessity of wind power generation participating in primary frequency regulation is also increasing. Most traditional doubly-fed induction generators do not have the capability of frequency regulation control. To solve this problem, the primary frequency regulation strategy for doubly-fed induction generators is designed based by using the inertia of wind turbines. The power control principle and frequency response process of doubly-fed induction generators are studied. On this basis, a strategy of primary frequency regulation based on virtual inertia is proposed. The method enhances the ability of the doubly-fed induction generator to adjust transient and steady-state power when the frequency of the power network changes, and realizes the doubly-fed generators to take part in the primary frequency regulation of the power system. The 3-generator 9-bus model is built using MATLAB/Simulink, in which wind power capacity accounted for 20%. Using this model, it is verified that the virtual inertia strategy can make the output power of doubly-fed generator change with the frequency of the power grid, can effectively participate in the primary frequency regulation of the power grid. © 2024 J. Zhao and Z. Dou, Published by EDP Sciences.
引用
收藏
相关论文
共 18 条
[11]  
Meng J., Shi X., Wang Y., Et al., Control strategy of DER inverter for improving frequency stability of microgrid, Trans. China Elctrotech. Soc., 30, pp. 70-79, (2015)
[12]  
Panayiotis M., Stavros A., Papathanassiou N.D., Improved load-frequency control contribution of variable speed variable pitch wind generators, Renew. Energy, 48, pp. 514-523, (2012)
[13]  
Fan G., Liu J., Meng H., Et al., Research on primary frequency control for wind farmsi under output-restricted condition, Power Syst. Technol., 40, pp. 1-9, (2016)
[14]  
Pan W., Quan R., Wang F., Avariable droop control strategy for doubly-fed induction generator, Autom. Electr. Power Syst., 39, pp. 126-131, (2015)
[15]  
Mi Z., Liu L., Yu Y., Et al., The control strategy of active power and frequency regulation of DFIG under wind abandon condition, Trans. China Electrotech. Soc., 30, pp. 81-88, (2015)
[16]  
Anderson P.M., Mirheydar M., A low-order system frequency response model, IEEE Trans. Power Syst., 5, pp. 720-729, (1990)
[17]  
Shah D.S.P.K.G., Alow order system frequency response model for largepowersystemandadaptiveloadshedding, Ternational Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering, 4, pp. 3845-3852, (2015)
[18]  
Delavari A., Kamwa I., Brunelle P., Simscape power systems benchmarks for education and research in power grid dynamics and control, 2018 IEEE Canadian Conference on Electrical & Computer Engineering (CCECE), pp. 1-5, (2018)