Introduction: The aim of this study was to evaluate and measure the effectiveness of a particular radiotherapy treatment planning system, namely 3D conformal radiation therapy (3D-CRT), and radiobiological effects in postmastectomy breast cancer axillary lymph metastases using a patient-specific 3D printed anthropomorphic phantom of the right breast after surgery. Material and Methods: The chest wall and axilla were the two treatment targets for 3D-CRT planning techniques. Each target was subjected to variations of two and three irradiation fields, with a dose of 50.00 Gy and fractionation of 2.00 Gy. From the variations, the radiation dose received by planning target volume (PTV) chest wall, PTV-Axillary, and organs at risk (OARs) was evaluated to determine the best planning technique through dosimetry verification. The thermoluminescent dosimeter (TLD) 100 Chip and EBT3 film were employed to measure the radiation dose at the PTV and OARs. Results: The planning system evaluation based on dose volume histogram showed no significant difference (p = 0.993) between two and three irradiation fields in both the chest wall and axillary planning 3D-CRT technique. Normal tissue complication probability for OARs has values below 5%, while the smallest value was obtained for the left lung. Finally, the point dose verification between planning and measurement using TLD100 and EBT3 film indicated an average difference of 9.14% and 4.34%, respectively, with no significant difference. Conclusion: This study successfully demonstrated the dosimetry evaluation and radiobiological effects of postmastectomy right breast cancer treatment using a patient-specific 3D printed anthropomorphic phantom, which met the established standards. © (2024), (Mashhad University of Medical Sciences). All rights reserved.
引用
收藏
页码:314 / 322
页数:8
相关论文
共 50 条
[21]   A patient-specific deep learning framework for 3D motion estimation and volumetric imaging during lung cancer radiotherapy [J].
Hindley, Nicholas ;
Shieh, Chun-Chien ;
Keall, Paul .
PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14)
[22]   A comparative planning study on the treatment of gastric cancer patients with tomotherapy, coplanar and non-coplanar three-dimensional conformal radiotherapy (3D-CRT) [J].
Kazemzadeh, A. ;
Mahani, L. ;
Kianinia, M. ;
Shanei, A. .
INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2024, 22 (04) :837-843
[23]   Analysis of Intensity-Modulated Radiation Therapy (IMRT), Proton and 3D Conformal Radiotherapy (3D-CRT) for Reducing Perioperative Cardiopulmonary Complications in Esophageal Cancer Patients [J].
Ling, Ted C. ;
Slater, Jerry M. ;
Nookala, Prashanth ;
Mifflin, Rachel ;
Grove, Roger ;
Ly, Anh M. ;
Patyal, Baldev ;
Slater, Jerry D. ;
Yang, Gary Y. .
CANCERS, 2014, 6 (04) :2356-2368
[24]   Evaluation of geometrical uncertainties on localized prostate radiotherapy of patients with bilateral metallic hip prostheses using 3D-CRT, IMRT and VMAT: A planning study [J].
Soda, Rikana ;
Hatanaka, Shogo ;
Hariu, Masatsugu ;
Shimbo, Munefumi ;
Yamano, Takafumi ;
Nishimura, Keiichiro ;
Kondo, Shuichi ;
Utsumi, Nobuko ;
Takahashi, Takeo .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (02) :243-254
[25]   Comparison of 3D conformal and intensity modulated radiotherapy in early stage oral tongue cancer: dosimetric and radiobiological evaluation [J].
Shanei, A. ;
Abedi, I. ;
Saadatmand, P. ;
Amouheidari, A. R. ;
Akbari-Zadeh, H. .
INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (01) :33-42
[26]   The Value of Using Patient-Specific 3D-Printed Anatomical Models in Surgical Planning for Patients With Complex Multifibroid Uteri [J].
Flaxman, Teresa E. ;
Cooke, Carly M. ;
Miguel, Olivier X. ;
Sheikh, Adnan ;
McInnes, Matthew ;
Duigenan, Shauna ;
Singh, Sukhbir Sony .
JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2024, 46 (06)
[27]   Continuous table acquisition MRI for radiotherapy treatment planning: Distortion assessment with a new extended 3D volumetric phantom [J].
Walker, Amy ;
Liney, Gary ;
Holloway, Lois ;
Dowling, Jason ;
Rivest-Henault, David ;
Metcalfe, Peter .
MEDICAL PHYSICS, 2015, 42 (04) :1982-1991
[28]   Cardiac dose in the treatment of synchronous bilateral breast cancer patients between three different radiotherapy techniques (VMAT, IMRT, and 3D CRT) [J].
Salim, Nidal ;
Popodko, Alexey ;
Tumanova, Kristina ;
Stolbovoy, Alexandr ;
Lagkueva, Irina ;
Ragimov, Vadim .
DISCOVER ONCOLOGY, 2023, 14 (01)
[29]   Cardiac dose in the treatment of synchronous bilateral breast cancer patients between three different radiotherapy techniques (VMAT, IMRT, and 3D CRT) [J].
Nidal Salim ;
Alexey Popodko ;
Kristina Tumanova ;
Alexandr Stolbovoy ;
Irina Lagkueva ;
Vadim Ragimov .
Discover Oncology, 14
[30]   Plan Dose Evaluation of Three Dimensional Conformal Radiotherapy Planning (3D-CRT) of Nasopharyngeal Carcinoma (NPC): Experience of a Tertiary Care University Hospital in Pakistan [J].
Abbasi, Ahmed Nadeem ;
Hafiz, Asim ;
Ali, Nasir ;
Khan, Khurshid Ahmed .
ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2013, 14 (10) :5989-5993