A Fast Variance Reduction Technique for Efficient Radiation Shielding Calculations in Nuclear Reactors

被引:0
|
作者
Jo, Seungjae [1 ]
Kim, Sanghwan [2 ]
Cho, Jaehyun [1 ]
机构
[1] Chung Ang Univ, Sch Energy Syst Engn, Seoul 06974, South Korea
[2] Korea Res Inst Ships & Ocean Engn, Daejeon 34103, South Korea
关键词
Monte Carlo; MCNP; variance reduction technique; radiation shielding; fast reactor; DESIGN; FUEL;
D O I
10.3390/en17225695
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The increasing demand for cleaner and more sustainable energy sources has sparked significant interest in small modular reactors (SMRs). Due to their compact and modular design, SMRs pose unique challenges in radiation shielding, requiring a more refined approach. This study focuses on developing a new variance reduction technique (VRT) for radiation shielding analysis, specifically tailored for SMRs, to address the limitations of traditional methods such as surface source write/surface source read (SSW/SSR). The proposed VRT supports multi-threading and enhances computational efficiency by redefining source particles using a two-step method. The analysis is conducted using the Monte Carlo radiation transport code, MCNP6, and the effectiveness of the new VRT is evaluated through sensitivity analyses across various energy and directional divisions.
引用
收藏
页数:16
相关论文
共 7 条
  • [1] Application of a variance reduction technique to Surface-to-Surface Monte Carlo radiation exchange calculations
    Mazumder, Sandip
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 131 : 424 - 431
  • [2] Verification of the on-the-fly global variance reduction technique on Monte Carlo global coupled neutron photon shielding calculations
    Zheng, Yu
    Qiu, Yuefeng
    Lu, Peng
    Chen, Yixue
    Fischer, Ulrich
    Liu, Songlin
    FUSION ENGINEERING AND DESIGN, 2021, 171
  • [3] Variance reduction technique in a beta radiation beam using an extrapolation chamber
    Polo, Ivon Oramas
    Santos, William Souza
    Antonio, Patricia de lara
    Caldas, Linda V. E.
    APPLIED RADIATION AND ISOTOPES, 2017, 128 : 154 - 157
  • [4] Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique
    Sampson, Andrew
    Le, Yi
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2012, 39 (02) : 1058 - 1068
  • [5] Research on fast intelligence multi-objective optimization method of nuclear reactor radiation shielding
    Song, Yingming
    Zhang, Zehuan
    Mao, Jie
    Lu, Chuan
    Tang, Songqian
    Xiao, Feng
    Lyu, Huanwen
    ANNALS OF NUCLEAR ENERGY, 2020, 149
  • [6] An improved on-the-fly global variance reduction technique by automatically updating weight window values for Monte Carlo shielding calculation
    Zheng, Yu
    Qiu, Yuefeng
    Lu, Peng
    Chen, Yixue
    Fischer, Ulrich
    Liu, Songlin
    FUSION ENGINEERING AND DESIGN, 2019, 147
  • [7] Evaluation of radiation shielding potentials of Ni-based alloys, Inconel-617 and Incoloy-800HT, candidates for high temperature applications especially for nuclear reactors, by EpiXS and Phy-X/PSD codes
    Aygun, Zeynep
    Aygun, Murat
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2023, 26 (02): : 795 - 801