Design and simulation of a liquid-microjet time-of-flight mass spectrometer with a femtosecond laser ionization source

被引:0
|
作者
Long, Jinyou [1 ,2 ]
Wei, Jie [1 ,2 ]
Wang, Yaping [3 ]
Zhang, Song [1 ,2 ]
Zhang, Bing [1 ]
机构
[1] Chinese Acad Sci, Wuhan Inst Phys & Math, Innovat Acad Precis Measurement Sci & Technol, State Key Lab Magnet Resonance & Atom & Mol Phys, Wuhan 430071, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Hefei Univ Technol, Xuancheng Campus, Xuancheng 242000, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid microjet; Time-of-flight; Mass spectrometer; Aqueous solution; DESORPTION IONIZATION; ION-SOURCE; BEAM; WATER; PHOTOELECTRON; MOLECULES; FEATURES; DYNAMICS;
D O I
10.1063/1674-0068/cjcp2407092
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A liquid-microjet (LJ) linear time-of-flight (TOF) mass spectrometer, coupled with a femtosecond laser ionization source, has been designed for direct measurements of mass spectra of liquid aqueous solutions. Two main features of our designed spectrometer involve the coupling of a liquid microjet nozzle to a conventional ion optics and the application of femtosecond pulses for mass spectral ionization. The detailed design, construction, and simulation of this new spectrometer are presented. More importantly, we combined the experimental tests with the simulated electric fields and ion trajectories to investigate the performance of the designed spectrometer, especially the kind of disturbances of the nozzle electric field on the conventional ion optics. In our current design, the optimal E/R (E: extractor, R: repeller) electrode voltage ratio was found to be similar to 0.71 when the voltages on the R, E and G (ground) electrodes were set to be 1500, 1060 and 0 V, respectively, whilst the voltage on the N nozzle electrode was required to be around 1250 V. The capability of the designed spectrometer has been demonstrated by recording the simulated mass spectra of the water, benzene and cytidine with their mass/charge ratios of 18, 76 and 243, respectively. This work shall be helpful for the development of new all-liquid-phase mass spectral technology to be employed in the diagnosis of diseases by the mass analysis of human body fluids.
引用
收藏
页码:797 / 806
页数:10
相关论文
共 50 条
  • [1] Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
    Tabrizchi, M.
    Farrokhpour, H.
    Abyar, F.
    Azad, H.
    Mirian, M.
    ILbeigi, V.
    PHYSICAL CHEMISTRY RESEARCH, 2014, 2 (02): : 202 - 216
  • [2] Design and performance of a matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometer
    Santacruz, C. P.
    Ayala, E.
    Costa-Vera, C.
    BRAZILIAN JOURNAL OF PHYSICS, 2006, 36 (3A) : 789 - 794
  • [3] Design and characterization of a recirculating liquid-microjet photoelectron spectrometer for multiphoton ultraviolet photoelectron spectroscopy
    Riley, Jamie W.
    Wang, Bingxing
    Parkes, Michael A.
    Fielding, Helen H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (08):
  • [4] Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry using a femtosecond laser
    Imasaka, Totaro
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (22) : 6907 - 6912
  • [5] Miniature time-of-flight mass analyzer for use in combination with a compact highly-repetitive femtosecond laser ionization source
    Yoshinaga, Katsunori
    Hao, Nguyen, V
    Imasaka, Totaro
    Imasaka, Tomoko
    ANALYTICA CHIMICA ACTA, 2022, 1203
  • [6] TOFSim: A LabView Based Time-of-Flight Mass Spectrometer Simulation
    Fulmer, Bryan
    Duong, Ahn
    Palmer, Hannah
    Owens, Kevin G.
    JOURNAL OF CHEMICAL EDUCATION, 2024, 101 (04) : 1507 - 1513
  • [7] Miniature time-of-flight mass spectrometer
    McLoughlin, MP
    Anderson, CW
    Bryden, WA
    Carlson, MA
    Ecelberger, SA
    Ko, HW
    BIOMEDICAL SENSING AND IMAGING TECHNOLOGIES, PROCEEDINGS OF, 1998, 3253 : 155 - 164
  • [8] High-resolution electrospray ionization orthogonal-injection time-of-flight mass spectrometer
    Dodonov, AF
    Kozlovski, VI
    Soulimenkov, IV
    Raznikov, VV
    Loboda, AV
    Zhen, Z
    Horwath, T
    Wollnik, H
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2000, 6 (06) : 481 - 490
  • [9] A Reflectron Time-of-Flight Mass Spectrometer with a Nano-Electrospray Ionization Source for Study of Metal Cluster Compounds
    Wu, Xiao-hu
    Xie, Hua
    Liu, Zhi-ling
    Su, Hai-feng
    Lin, Shui-chao
    Tang, Zi-chao
    CHINESE JOURNAL OF CHEMICAL PHYSICS, 2016, 29 (04) : 401 - 406
  • [10] The laser reflectron time-of-flight mass spectrometer used on cluster research
    Xing, XP
    Tian, ZX
    Liu, P
    Gao, Z
    Zhu, Q
    Tang, ZC
    CHINESE JOURNAL OF CHEMICAL PHYSICS, 2002, 15 (02): : 83 - 87