Manuscript title: Experimental investigations of concrete-filled double skin steel tube column-column grouted connection under axial compression

被引:0
|
作者
Wang, Zhanwen [1 ]
Chen, Jianwei [2 ]
Zhang, Rui [1 ]
机构
[1] North China Univ Sci & Technol, Coll Min Engn, Tangshan, Peoples R China
[2] North China Univ Sci & Technol, Coll Civil & Architectural Engn, Tangshan, Peoples R China
基金
中国国家自然科学基金;
关键词
CFDST column; Grouted connection; Axial compression performance; Casing tube; Ultimate bearing capacity; SLEEVE CONNECTIONS; MECHANICAL-BEHAVIOR; NONLINEAR-ANALYSIS; STUB COLUMNS; PIPE SPLICE; TENSILE; DESIGN; PERFORMANCE; STRENGTH;
D O I
10.1016/j.conbuildmat.2024.138972
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a novel grouted connection joint for prefabricated CFDST columns. In order to ascertain the reliability of this grouted connection, axial compression tests were conducted on 24 CFDST columns with grouted connections and 3 CFDST columns without grouted connections. The test parameters were grout strength, casing tube length, and length-to-diameter ratio. The results showed that the stub columns failed due to local buckling and the slender columns failed due to global buckling with significant lateral flexural deformation. CFDST columns with grouted connections exhibited a similar or even higher ultimate bearing capacity and much higher later bearing capacity than conventional CFDST columns. The ultimate bearing capacity of CFDST columns with grouted connections is influenced by the casing tube length and the length-to-diameter ratio. The increase in casing tube length leads to an increase in bearing capacity, while an increase in length-to-diameter ratio results in a decrease. Enhancing the grout strength does not significantly improve the ultimate bearing capacity. Furthermore, the effects of each test parameter on the stiffness, strength and ductility of the CFDST columncolumn grouted connections were evaluated. Finally, by considering the interaction between components and the impact of casing tube length on bearing capacity, a prediction equation for the ultimate bearing capacity of CFDST column-column grouting connections was developed. This equation can offer accurate predictions with an average error of less than 1 % to provide a reference for the joint design.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Experimental study on concrete filled steel tube column to outrigger truss connection
    Wang, W. (weiwang@tongji.edu.cn), 1600, Tsinghua University (30):
  • [32] Theoretical Study on Local Buckling of Steel Plate in Concrete filled Tube Column under Axial Compression
    Qin, Ying
    Lu, Jin-Yu
    Cao, Shi
    ISIJ INTERNATIONAL, 2017, 57 (09) : 1645 - 1651
  • [33] Study on steel reinforced concrete-filled GFRP tubular column under compression
    Xue, Bing
    Gong, Jian
    THIN-WALLED STRUCTURES, 2016, 106 : 1 - 8
  • [34] Experiment on compression performance of preplaced aggregate concrete-filled steel tube slender column
    Lü, Jing
    Zheng, Jianlong
    Han, Wenchao
    Zhang, Jinyi
    Zhao, Huan
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2024, 55 (06): : 2247 - 2259
  • [35] Experimental Study and Analysis on Axial Compression Performance of High-Strength Recycled Concrete-Filled Steel Tube Column in Corrosive Environments
    Cun Hui
    Ke Li
    Yonggang Li
    Yadong Bian
    Ran Hai
    Chunqing Li
    International Journal of Steel Structures, 2022, 22 : 450 - 471
  • [36] Experimental Study and Analysis on Axial Compression Performance of High-Strength Recycled Concrete-Filled Steel Tube Column in Corrosive Environments
    Hui, Cun
    Li, Ke
    Li, Yonggang
    Bian, Yadong
    Hai, Ran
    Li, Chunqing
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2022, 22 (02) : 450 - 471
  • [37] Experimental study on hollow concrete-filled double skin steel tubular column wrapped with PET under horizontal force
    Institute of Structural Engineering, Zhejiang University, Hangzhou
    310058, China
    Jianzhu Jiegou Xuebao, (235-239):
  • [38] Study on Seismic Behavior of T-shaped Concrete-filled Steel Tube Compound Column under Different Axial Compression Ratios
    Xu, Yafeng
    Song, Jian
    Sun, Pengju
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 1539 - 1542
  • [39] Experimental and Numerical Investigation of Concrete-Filled Double-Skin Steel Tubular Column for Steel Beam Joints
    Zhang, Dongfang
    Zhao, Junhai
    Zhang, Yufen
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [40] A Simplified method for Concrete-Filled Steel Tube Column Analysis
    Pan, Danguang
    Li, Zheng
    Tan, Jinpeng
    Gao, Hongchun
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 537 - +