Characteristics of Sterilised Nickel Titanium and Stainless Steel Orthodontic Archwires

被引:0
作者
Abood, Akhlas Zeid [1 ,2 ]
Noor, Siti Noor Fazliah Mohd [2 ,3 ]
Suhaimi, Fatanah Mohamad [2 ,3 ]
Al-Fatlawi, Fakhri Abid Ali Hussein [4 ]
Shafiai, Noor Ayuni Ahmad [2 ]
机构
[1] Middle Tech Univ, Coll Hlth & Med Tech, Dept Prosthet Dent Tech, Baghdad 10074, Iraq
[2] Univ Sains Malaysia, Adv Med & Dent Inst, Dept Dent Sci, Kepala Batas 13200, Pulau Pinang, Malaysia
[3] Univ Sains Malaysia, Adv Med & Dent Inst, Dent Stimulat & Virtual Learning, Res Excellence Consortium, Kepala Batas 13200, Pulau Pinang, Malaysia
[4] Al Farabi Collect Coll, Baghdad 11691, Iraq
关键词
sterilisation method; super elastic NiTi; stainless steel wire; archwire; surface morphology; MECHANICAL-PROPERTIES; SURFACE-ROUGHNESS; WIRES;
D O I
10.21315/jps2024.35.3.3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Sterilisation removes microorganisms in the vegetative or spore states from a material, surface or medium. Ensuring infection control is of utmost importance for health safety. Pathogenic microorganisms are frequently transmitted from one person to another because of ineffective sterilising agents, apparatus and equipment. The aim of this study is to investigate the effect of sterilisation methods on morphological parameters of super elastic nickel titanium (NiTi) and stainless steel (SS) orthodontic archwires. The archwires were sterilised using a variety of methods, including dry heat sterilisation (oven) at 160 degrees C for 1 h, steam heat sterilisation (autoclave) at 121 degrees C for 15 min and cold sterilisation (2% glutaraldehyde) at 10 h. After sterilisation, the wires were tested, and the morphological changes was determined through atomic force microscopy (AFM), scanning electron microscopy (SEM) and X-ray diffraction (XRD). The AFM and SEM results obtained before and after the sterilisation of the NiTi and SS orthodontic archwires did not show clear differences in the surface structure. No changes in the elemental composition of the NiTi and SS wires, and no new phase appeared according to the XRD results which support the use of archwire sterilisation procedures as part of the infection control treatment and are considered a suitable procedure related to the characterisation of the orthodontic archwires.
引用
收藏
页码:27 / 48
页数:22
相关论文
共 50 条
  • [1] FRICTION OF STAINLESS STEEL, NICKEL-TITANIUM ALLOY, AND BETA-TITANIUM ALLOY ARCHWIRES IN TWO COMMONLY USED ORTHODONTIC BRACKETS
    Yu, Jian-Hong
    Huang, Heng-Li
    Wu, Li-Chun
    Hsu, Jui-Ting
    Chang, Yin-Yu
    Huang, Her-Hsiung
    Tsai, Ming-Tzu
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2011, 11 (04) : 917 - 928
  • [2] Comparative assessment of the corrosion process of orthodontic archwires made of stainless steel, titanium-molybdenum and nickel-titanium alloys
    Malkiewicz, Konrad
    Sztogryn, Mariola
    Mikulewicz, Marcin
    Wielgus, Andrzej
    Kaminski, Janusz
    Wierzchon, Tadeusz
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2018, 18 (03) : 941 - 947
  • [3] Surface characteristics of retrieved coated and nickel-titanium orthodontic archwires
    Zegan, Georgeta
    Sodor, Alina
    Munteanu, C.
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2012, 53 (04) : 935 - 939
  • [4] Morphological characterization of as-received and in vivo orthodontic stainless steel archwires
    Daems, Julie
    Celis, Jean-Pierre
    Willems, Guy
    EUROPEAN JOURNAL OF ORTHODONTICS, 2009, 31 (03) : 260 - 265
  • [5] EFFECTS OF THERMOCYCLING AND PH ON ULTRASTRUCTURES CHARACTERISTICS OF STAINLESS STEEL ARCHWIRES
    Sheibaninia, Ahmad
    Ojani, Zahra
    Zarrabi, Fatemeh
    Rabbani, Marzeih
    Heydari, Niloufar
    JP JOURNAL OF BIOSTATISTICS, 2019, 16 (02) : 139 - 149
  • [6] In vitro biocompatibility of nickel-titanium esthetic orthodontic archwires
    Rongo, Roberto
    Valletta, Rosa
    Buccia, Rosaria
    Rivieccio, Virginia
    Galeotti, Angela
    Michelotti, Ambrosina
    D'Anto, Vincenzo
    ANGLE ORTHODONTIST, 2016, 86 (05) : 789 - 795
  • [7] Comparison of Elastic Properties of Nickel-Titanium Orthodontic Archwires
    Sarul, Michal
    Kawala, Beata
    Antoszewska, Joanna
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2013, 22 (02): : 253 - 260
  • [8] Tribocorrosion Susceptibility and Mechanical Characteristics of As-Received and Long-Term In-Vivo Aged Nickel-Titanium and Stainless-Steel Archwires
    Primozic, Jasmina
    Hren, Miha
    Mezeg, Uros
    Legat, Andraz
    MATERIALS, 2022, 15 (04)
  • [9] Effect of gastric acids on surface topography and bending properties of esthetic coated nickel-titanium orthodontic archwires
    Elsaka, Shaymaa
    Hassan, Ali
    Elnaghy, Amr
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (03) : 1319 - 1326
  • [10] Load deflection characteristics and force level of nickel titanium initial archwires
    Lombardo, Luca
    Marafioti, Matteo
    Stefanoni, Filippo
    Mollica, Francesco
    Siciliani, Giuseppe
    ANGLE ORTHODONTIST, 2012, 82 (03) : 507 - 521