Retrievability of Fractured Abutment Screws and Damage to Implant–Abutment Connections: An In Vitro Comparative Analysis of Conventional vs. Drilling Techniques

被引:0
|
作者
Martínez-Alcaraz, Paloma [1 ]
Flores-Fraile, Javier [2 ]
Agustín-Panadero, Rubén [3 ]
Senent-Vicente, Gisela [3 ]
Gómez-Polo, Cristina [2 ]
de la Cruz-Jiménez, Silvia [1 ]
Zubizarreta-Macho, Álvaro [1 ,2 ]
Lobo Galindo, Ana Belén [2 ]
机构
[1] Faculty of Dentistry, Alfonso X El Sabio University, Madrid
[2] Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, Salamanca
[3] Department of Stomatology, Faculty of Medicine and Dentistry, Universiat of València, Valencia
来源
Applied Sciences (Switzerland) | 2024年 / 14卷 / 24期
关键词
abutment screw; dental implants; dental prostheses; fractured; implant-supported prostheses; screw retain;
D O I
10.3390/app142411846
中图分类号
学科分类号
摘要
This study aimed to evaluate the retrievability and potential damage to implant–abutment connections caused by fractured abutment screw removal using conventional and drilling techniques. A total of forty abutment screws were randomly inserted into forty dental implants, and then they were fractured and extracted using different removal methods: Group A employed a conventional approach utilizing an exploration probe and an ultrasonic device without irrigation (n = 10) (conventional); Group B used the Phibo drilling removal system without irrigation (n = 10) (Phibo); Group C utilized the Rhein83® drilling removal system without irrigation (n = 10) (Rhein83); and Group D implemented the Sanhigia® drilling removal system without irrigation (n = 10) (Sanhigia). Pre- and postoperative micro-computed tomography (micro-CT) scans were performed on the dental implants, and Standard Tessellation Language (STL) digital files were generated for morphometric analysis to measure the wear volume. ANOVA was used to assess the volumetric differences (mm3) and percentage ratios of the internal thread volumes of the implant–abutment connections before and after the procedures. Results: This study found no statistically significant differences in the volumetric and percentage ratios of internal threads among the implant groups (Phibo, Rhein83, Sanhigia, and conventional). However, the success rate for retrieving fractured abutment screws was higher (90%) with the drilling systems compared to the conventional technique (50%). These results suggest that drilling systems are more effective for the retrieval of damaged screws. Although drilling techniques without irrigation demonstrated higher removal efficiency compared to the conventional method, both approaches resulted in similar wear volumes at the implant–abutment connections when used to extract fractured screws. © 2024 by the authors.
引用
收藏
相关论文
共 13 条
  • [1] Removal capability, implant-abutment connection damage and thermal effect using ultrasonic and drilling techniques for the extraction of fractured abutment screws: an in vitro study
    María Bufalá Pérez
    Álvaro Zubizarreta-Macho
    Javier Borrajo Sánchez
    Jorge Hernández Rodríguez
    Jorge Alonso Pérez-Barquero
    Elena Riad Deglow
    Sofía Hernández Montero
    BMC Oral Health, 22
  • [2] Removal capability, implant-abutment connection damage and thermal effect using ultrasonic and drilling techniques for the extraction of fractured abutment screws: an in vitro study
    Bufala Perez, Maria
    Zubizarreta-Macho, Alvaro
    Borrajo Sanchez, Javier
    Hernandez Rodriguez, Jorge
    Alonso Perez-Barquero, Jorge
    Riad Deglow, Elena
    Hernandez Montero, Sofia
    BMC ORAL HEALTH, 2022, 22 (01)
  • [3] Mechanical Comparison of Experimental Conical-Head Abutment Screws with Conventional Flat-Head Abutment Screws for External-Hex and Internal Tri-Channel Implant Connections: An In Vitro Evaluation of Loosening Torque
    Coppede, Abilio Ricciardi
    Lapria Faria, Adriana Claudia
    Chiarello de Mattos, Maria da Gloria
    Silveira Rodrigues, Renata Cristina
    Shibli, Jamil Awad
    Ribeiro, Ricardo Faria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : E321 - E329
  • [4] Survival of Four Conical Implant Abutment Connections After Removal of the Abutment Screw and Simulated Cyclic Loading: An In Vitro Comparative Study
    Yao, Kuang-Ta
    Chang, Tsai-Yu
    Huang, Guan-Jhong
    Fang, Hsu-Wei
    Wang, Ding-Han
    Hsu, Ming-Lun
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (04) : 393 - 400
  • [5] Comparative Analysis of Internal Tapered Implant- Abutment Connections: the Morse Effect
    Barbosa Marchon, Renata Nogueira
    Mourao, Carlos Fernando
    Rutkowski, James L.
    Ghanaati, Shahram
    Mello-Machado, Rafael Coutinho
    Senna, Plinio Mendes
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (04) : 431 - 434
  • [6] In Vitro Analysis of the Removability of Fractured Prosthetic Screws within Endosseous Implants Using Conventional and Mechanical Techniques
    Senent-Vicente, Gisela
    Baixauli-Lopez, Mar
    Gonzalez-Angulo, Eva
    Fernandez-Bravo, Luisa
    Zubizarreta-Macho, Alvaro
    Gomez-Polo, Miguel
    Selva-Otaolaurruchi, Eduardo J.
    Agustin-Panadero, Ruben
    MATERIALS, 2023, 16 (23)
  • [7] In vitro mechanical analysis of complete-arch mandibular implant-supported fixed prostheses abutment screws after cyclic loading
    Sananez, Andreina
    Lefebvre, Carol
    Looney, Stephen
    Baker, Philip
    Mettenburg, Don
    Rueggeberg, Frederick A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (05) : 432 - 439
  • [8] Biomechanical evaluation of abutment stability in morse taper implant connections in different times: A retrospective clinical study compared with an in vitro analysis
    Gehrke, Sergio Alexandre
    Cortellari, Guillermo Castro
    De Aza, Piedad N.
    de Lima, Jose Henrique Cavalcanti
    Frutos, Juan Carlos Prados
    HELIYON, 2023, 9 (04)
  • [9] Influence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant-Abutment Interface: An In Vitro Study
    Cascos, Rocio
    Celemin-Vinuela, Alicia
    Mory-Rubinos, Nataly
    Gomez-Polo, Cristina
    Ortega, Rocio
    Agustin-Panadero, Ruben
    Gomez-Polo, Miguel
    MATERIALS, 2023, 16 (19)
  • [10] Navigated vs. conventional implant insertion for maxillary single tooth replacement -: A comparative in vitro study
    Kramer, FJ
    Baethge, C
    Swennen, G
    Rosahl, S
    CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (01) : 60 - 68