Combustion characteristics of a 660 MW tangentially fired pulverized coal boiler considering different loads, burner combinations and horizontal deflection angles

被引:2
|
作者
Gu, Wenbo [1 ,2 ]
Zheng, Zipeng [1 ,2 ]
Zhao, Naixin [1 ,2 ]
Wang, Xiaojian [1 ,2 ]
Cheng, Zening [3 ]
机构
[1] School of Electrical Engineering, Xinjiang University, Xinjiang, Urumqi,830047, China
[2] Engineering Research Center of Northwest Energy Carbon Neutrality, Ministry of Education, China
[3] Zhundong Energy Research Institute, Xinjiang Tianchi Energy Co., Ltd, Changji,831100, China
关键词
This study conducts a detailed analysis of combustion dynamics and pollutant emissions in a 660 MW pulverized coal boiler under different operational conditions. It combines various burner configurations and deflection angles to comprehensively assess their impact on combustion and pollutant emissions. The study employs the Analytic Network Process (ANP) [22; a method capable of effectively addressing the hierarchical relationships and interdependencies among key factors; offering a more in-depth decision-support framework compared to traditional single-criterion analysis. By incorporating six critical parametersu2014temperature; O2; CO; CO2; SO2; and NOu2014and assigning weights to each operational scenario; the study systematically evaluates the optimal burner arrangement and deflection angle under different operating conditions; thereby optimizing the combustion process and minimizing emissions.The authors would appreciate the financial support provided by Major Science and Technology Projects of Xinjiang Uygur Autonomous Region (2023A01005-2); Natural Science Foundation of Xinjiang Uygur Autonomous Region (2022D01C87); Special Fund Project for Central Guidance of Local Scientific and Technological Development (ZYYD2022C16); and Tianshan Talent Training Plan (2022TSYCJC0031).The authors would appreciate the financial support provided by Major Science and Technology Projects of Xinjiang Uygur Autonomous Region (2023A01005-2); and Tianshan Talent Training Plan (2022TSYCJC0031);
D O I
10.1016/j.csite.2024.105520
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] Numerical simulation of the heat transfer and NOXemissions in a 660 MW tangentially fired pulverised-coal supercritical boiler
    Sankar, G.
    Dhannina, Chandra Sekhar
    Santhosh, Kumar D.
    Balasubramanian, K. R.
    HEAT AND MASS TRANSFER, 2020, 56 (09) : 2693 - 2709
  • [32] Effects of structural parameters of a novel burner scheme with annularly combined multiple airflows on performance of a 660 MW tangentially fired boiler
    Li, Zixiang
    Miao, Zhengqing
    Qiao, Xinqi
    ENERGY, 2023, 280
  • [33] Numerical investigation of stable combustion at ultra-low load for a 350 MW wall tangentially fired pulverized-coal boiler: Effect of burner adjustments and methane co-firing
    Liu, Tao
    Wang, Yungang
    Zou, Li
    Bai, Yanyuan
    Shen, Tao
    Wei, Yuwei
    Li, Feixiang
    Zhao, Qinxin
    APPLIED THERMAL ENGINEERING, 2024, 246
  • [34] Numerical study on combustion process and NOx emissions in a 350 MW pulverized coal fired boiler
    Zhang, Jie
    Wu, Shao-Hua
    Sun, Rui
    Chen, Bing-Hua
    Qin, Yu-Kun
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2004, 36 (09): : 1239 - 1243
  • [35] Combustion and NOx emission characteristics of a retrofitted down-fired 660 MWe utility boiler at different loads
    Li, Zhengqi
    Liu, Guangkui
    Zhu, Qunyi
    Chen, Zhichao
    Ren, Feng
    APPLIED ENERGY, 2011, 88 (07) : 2400 - 2406
  • [36] Comparative Study on Combustion and Emission Characteristics of Torrefied and Ashless Biomass with Coal through the 500 MW Tangentially Fired Boiler Simulation
    Jiang, Yu
    Jeon, Chung-Hwan
    ENERGY & FUELS, 2021, 35 (01) : 561 - 574
  • [37] Influence of the Type of the Pulverized Coal Concentrator on the Operation of a Tangential Fired Boiler with Horizontal Bias Combustion
    管晓艳
    邹新丽
    孙绍增
    Journal of Shanghai Jiaotong University(Science), 2016, 21 (04) : 450 - 456
  • [38] Influence of the type of the pulverized coal concentrator on the operation of a tangential fired boiler with horizontal bias combustion
    Guan X.
    Zou X.
    Sun S.
    Journal of Shanghai Jiaotong University (Science), 2016, 21 (4) : 450 - 456
  • [39] Numerical simulation of the heat transfer and NOX emissions in a 660 MW tangentially fired pulverised-coal supercritical boiler
    Sankar G
    Chandra Sekhar Dhannina
    Santhosh Kumar D
    Balasubramanian K R
    Heat and Mass Transfer, 2020, 56 : 2693 - 2709
  • [40] Influence of Boiler Load on Generation Characteristics of PM2.5 Generated by a 660 MW Pulverized Coal Boiler
    Du, Qian
    Dong, Heming
    Su, Lipeng
    Zhao, Zhifeng
    Lv, Donghui
    Wang, Min
    ENERGY & FUELS, 2016, 30 (05) : 4300 - 4306