Comparative Calorimetric Method for Magnetic Component Losses Measurement With High Frequency

被引:1
|
作者
Wang, Jinghui [1 ]
Fan, Peng [1 ]
Lin, Shuang [1 ]
Huang, Fubin [2 ]
Chen, Wei [1 ]
机构
[1] Fuzhou Univ, Coll Elect Engn & Automat, Fuzhou 350108, Peoples R China
[2] Delta Elect Co Ltd, Shanghai 200000, Peoples R China
基金
中国国家自然科学基金;
关键词
Comparative calorimetric method; core losses; high frequency; measurement; ACCURATE MEASUREMENT; FERRITE;
D O I
10.1109/JESTPE.2024.3417354
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article investigates the loss measurement methods of magnetic components for power conversion applications. A comparison calorimetric method is proposed for magnetic component loss measurement, and the proposed method can eliminate measurement errors of the traditional calorimetric method. The measurement principle is introduced in detail and this method is realized, and possible sources of error in measurement are evaluated and addressed. Hysteresis control is utilized to achieve automated measurement. Resistor and air-core inductor are used to verify the accuracy of the proposed method. The results show that the proposed method can be used to measure the loss of resistor and inductive element for high frequency up to 5 MHz, and the range of loss is 0.1-10 W.
引用
收藏
页码:5112 / 5122
页数:11
相关论文
共 50 条
  • [1] New Core Loss Measurement Method for High Frequency Magnetic Materials
    Mu, Mingkai
    Li, Qiang
    Gilham, David
    Lee, Fred C.
    Ngo, Khai D. T.
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 4384 - 4389
  • [2] Calorimetric Measurement of Stator Core Losses
    Singh, Deepak
    Arkkio, Antero
    2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2012, : 1206 - 1211
  • [3] New Core Loss Measurement Method for High-Frequency Magnetic Materials
    Mu, Mingkai
    Li, Qiang
    Gilham, David Joel
    Lee, Fred C.
    Ngo, Khai D. T.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (08) : 4374 - 4381
  • [4] Comparison of Losses Measurement in a Ferrite With Two Calorimetric Methods
    Loyau, Vincent
    LoBue, Martino
    Mazaleyrat, Frederic
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (02) : 529 - 531
  • [5] Improved Oscillation Method for High-Frequency Magnetic Core Loss Measurement
    Xiang, Dawei
    Sun, Zhiwen
    Li, Hao
    Hu, Hangkang
    Zhong, Hongsheng
    Lu, Guolin
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (01) : 1577 - 1588
  • [6] A Simple Calorimetric Setup for the Accurate Measurement of Losses in Power Electronic Converters
    Dimitrakakis, G. S.
    Tatakis, E. C.
    Nanakos, A. Ch.
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [7] Liquidity measurement: A comparative review of the literature with a focus on high frequency
    Cobandag Guloglu, Zeynep
    Ekinci, Cumhur
    JOURNAL OF ECONOMIC SURVEYS, 2022, 36 (01) : 41 - 74
  • [8] Effects of magnetic domain morphology on the magnetic spectrum and high-frequency core losses of MnZn ferrites
    Wu, Guohua
    Yu, Zhong
    Guo, Rongdi
    Wang, Zhiguang
    Wang, Hong
    Hu, Zhongqiang
    Liu, Ming
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2024, 107 (02) : 1117 - 1126
  • [9] Temperature dependence of core losses at high frequency for MnZn ferrites
    Sun, Ke
    Lan, Zhongwen
    Yu, Zhong
    Li, Lezhong
    Jiang, Xiaona
    Ji, Haining
    PHYSICA B-CONDENSED MATTER, 2010, 405 (03) : 1018 - 1021
  • [10] New measurement method for high frequency cable mounted ferrites
    Weinschrott, A
    EMC 2005: IEEE International Symposium on Electromagnetic Compatibility, Vols 1-3, Proceedings, 2005, : 312 - 314