A review on chloride induced corrosion in reinforced concrete structures: lab and in situ investigation

被引:6
作者
Ali, Mohsin [1 ]
Shams, Muhammad Alamgeer [2 ]
Bheel, Naraindas [3 ]
Almaliki, Abdulrazak H. [4 ]
Mahmoud, Abubakar Sadiq [5 ,6 ]
Dodo, Yakubu Aminu [7 ]
Benjeddou, Omrane [8 ]
机构
[1] Yokohama Natl Univ, Grad Sch Urban Innovat, Dept Civil Engn, Yokohama, Kanagawa 2408501, Japan
[2] Univ Engn & Technol, Dept Civil Engn, Lahore, Pakistan
[3] Univ Teknol PETRONAS, Dept Civil & Environm Engn, Bandar Seri Iskandar Tron 32610, Perak, Malaysia
[4] Taif Univ, Coll Engn, Dept Civil Engn, Taif 21944, Saudi Arabia
[5] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Construct & Bldg Mat, Dhahran 31261, Saudi Arabia
[6] King Fahd Univ Petr & Minerals, Dammam Community Coll, Safety Technol, Dhahran 3126, Saudi Arabia
[7] Najran Univ, Coll Engn, Architectural Engn Dept, Najran 66426, Saudi Arabia
[8] Prince Sattam Bin Abdulaziz Univ, Coll Engn, Dept Civil Engn, Alkharj 16273, Saudi Arabia
关键词
STEEL CORROSION; ELECTROCHEMICAL TECHNIQUES; POLARIZATION RESISTANCE; OPTICAL-FIBER; ELECTRICAL-RESISTIVITY; BEHAVIOR; ELECTRODE; SENSORS; PERFORMANCE; LIMITATIONS;
D O I
10.1039/d4ra05506c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Reinforced concrete (RC) constructions are seriously threatened by chloride-induced corrosion (CIC) and carbonation, which can result in structural degradation, safety issues, and financial losses. Electrochemical methods and microstructural analysis tests are some of the laboratory techniques used to examine key elements of CIC, such as the impact of different variables and the efficacy of mitigation solutions. In situ studies that make use of non-destructive testing, chloride profiling, and half-cell potential measurements offer important new insights into the long-term performance and causes of RC structure deterioration in real-world circumstances. Non-destructive approaches for CIC detection are emerging these days and provide fruitful results. Studies have focused on the use of these approaches for CIC detection on small specimens in the lab as well as on full-scale experiments in the field. This review covers both in situ monitoring and laboratory studies to provide a thorough analysis of CIC.
引用
收藏
页码:37252 / 37271
页数:20
相关论文
共 127 条
[1]  
A E-B J of N-D Testing, 1990, Resistivity measurements in concrete
[2]   Evaluation of damage progression in concrete structures due to reinforcing steel corrosion using acoustic emission monitoring [J].
Abouhussien A.A. ;
Hassan A.A.A. .
Journal of Civil Structural Health Monitoring, 2015, 5 (05) :751-765
[4]  
Ahmad Z, 2006, PRINCIPLES OF CORROSION ENGINEERING AND CORROSION CONTROL, P609, DOI 10.1016/B978-075065924-6/50013-1
[5]   Effect of protective oxide scales in the macrogalvanic behaviour of concrete reinforcements [J].
Alonso, C ;
Andrade, C ;
Izquierdo, M ;
Novoa, XR ;
Perez, MC .
CORROSION SCIENCE, 1998, 40 (08) :1379-1389
[6]   Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method [J].
Andrade, C ;
Alonso, C ;
Gulikers, J ;
Polder, R ;
Cigna, R ;
Vennesland, O ;
Salta, M ;
Raharinaivo, A ;
Elsener, B .
MATERIALS AND STRUCTURES, 2004, 37 (273) :623-643
[7]   THE IMPORTANCE OF GEOMETRICAL CONSIDERATIONS IN THE MEASUREMENT OF STEEL CORROSION IN CONCRETE BY MEANS OF AC-IMPEDANCE [J].
ANDRADE, C ;
SOLER, L ;
ALONSO, C ;
NOVOA, XR ;
KEDDAM, M .
CORROSION SCIENCE, 1995, 37 (12) :2013-2023
[8]   QUANTITATIVE MEASUREMENTS OF CORROSION RATE OF REINFORCING STEELS EMBEDDED IN CONCRETE USING POLARIZATION RESISTANCE MEASUREMENTS [J].
ANDRADE, C ;
GONZALEZ, JA .
WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1978, 29 (08) :515-519
[9]   Metal Corrosion Rate Determination of Different Solutions and Reinforced Concrete Specimens by Means of a Noncontacting Corrosion Method [J].
Andrade, C. ;
Martinez, I. .
CORROSION, 2010, 66 (05)
[10]   Estimating corrosion attack in reinforced concrete by means of crack opening [J].
Andrade, Carmen ;
Cesetti, Alessandro ;
Mancini, Giuseppe ;
Tondolo, Francesco .
STRUCTURAL CONCRETE, 2016, 17 (04) :533-540