Securing X-Ray Images Into Cover Images Using Hybrid EBS Steganography With Five-Layer Cryptography

被引:0
作者
Sharma, Divya [1 ]
Prabha, Chander [1 ]
Hassan, Md Mehedi [2 ]
Abdulla, Shahab [3 ]
Bairagi, Anupam Kumar [2 ]
Alshathri, Samah [4 ]
El-Shafai, Walid [5 ,6 ]
机构
[1] Chitkara Univ, Inst Engn & Technol, Rajpura 140401, Punjab, India
[2] Khulna Univ, Comp Sci & Engn Discipline, Khulna 9208, Bangladesh
[3] Univ Southern Queensland, UniSQ Coll, Toowoomba, Qld 4305, Australia
[4] Princess Nourah Bint AbdulRahman Univ, Coll Comp & Informat Sci, Dept Informat Technol, POB 84428, Riyadh, Saudi Arabia
[5] Prince Sultan Univ, Comp Sci Dept, Secur Engn Lab, Riyadh 11586, Saudi Arabia
[6] Menoufia Univ, Fac Elect Engn, Dept Elect & Elect Commun Engn, Menoufia 32952, Egypt
关键词
Electromagnetic interference; X-ray imaging; Security; MATLAB; Steganography; Image edge detection; Encryption; Medical diagnostic imaging; Computed tomography; Electronic medical records; Cryptography; Electronic medical images (EMI); security; privacy; cryptography; steganography;
D O I
10.1109/ACCESS.2024.3489452
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electronic Medical Images (EMI) have grown with the increase in population. EMI are used for medical diagnosis for medical emergencies hence, they should be correct and clear for accurate diagnosis. In general, EMI are of varying sizes and dimensions. The aim is to enhance the security and privacy of EMI with reduced computational time while dealing with a larger and varying-sized data set. Reducing computational time will make the method suitable for real-time applications (RTA). Hence, a data set of 5856 secret X-ray images all varying in dimensions, total sized up to 1.16 GB, are applied with a hybrid of steganography and cryptography. Here, one X-Ray image is taken at a time then hidden into a single cover image using Edge-based steganography and then encrypted using five layers of cryptography. Various performance evaluation tests such as Structural Similarity Index Metrics (SSIM) achieved a value close to 1 which is the preferred value, Peak Signal-to-Noise Ratio (PSNR) is 82.51967 dB which is good, Mean Square Error (MSE) is 5.6E-09 which is close to zero indicating no addition of noise in the retrieved X-ray images, the Correlation (R) is 1. Therefore, the extracted image is the same as the original X-ray images, while remaining tests such as RMSE, Entropy, KLD, BER, SNR, CV, MAPE, PRD, etc. achieved good results. The computational time is measured by the Encryption Time (ET) is 0.37 seconds while the Decryption Time (DT) is 3.9275 sec. Thus, it can be concluded that a hybrid method (HM) could be implemented for RTA.
引用
收藏
页码:165050 / 165067
页数:18
相关论文
共 50 条
[31]   Semantic Segmentation on Panoramic Dental X-Ray Images Using U-Net Architectures [J].
Zannah, Rafiatul ;
Bashar, Mubtasim ;
Bin Mushfiq, Rahil ;
Chakrabarty, Amitabha ;
Hossain, Shahriar ;
Jung, Yong Ju .
IEEE ACCESS, 2024, 12 :44598-44612
[32]   Intrafraction Verification of Gated RapidArc by Using Beam-Level Kilovoltage X-Ray Images [J].
Li, Ruijiang ;
Mok, Edward ;
Chang, Daniel T. ;
Daly, Megan ;
Loo, Billy W., Jr. ;
Diehn, Maximilian ;
Quynh-Thu Le ;
Koong, Albert ;
Xing, Lei .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (05) :E709-E715
[33]   An image processing algorithm to estimate bone mineral density using digital X-ray images [J].
Khan, Shiyana Sherief ;
Jayan, Archana S. ;
Nageswaran, Sharmila .
PROCEEDINGS OF THE 2017 IEEE SECOND INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION TECHNOLOGIES (ICECCT), 2017,
[34]   3D registration of MR and X-ray spine images using an articulated model [J].
Harmouche, Rola ;
Cheriet, Farida ;
Labelle, Hubert ;
Dansereau, Jean .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2012, 36 (05) :410-418
[35]   Proposal of an algorithm for analysis of bone demineralization using synchrotron radiation X-ray μCT images [J].
Gomes Pinheiro, Christiano Jorge ;
de Moura Meneses, Anderson Alvarenga ;
Braz, Delson ;
de Oliveira, Luis Fernando ;
Rodrigues Barroso, Regina Cely .
RADIATION PHYSICS AND CHEMISTRY, 2014, 95 :258-260
[36]   Automatic Lung Segmentation in Chest X-Ray Images Using SAM With Prompts From YOLO [J].
Khalili, Ebrahim ;
Priego-Torres, Blanca ;
Leon-Jimenez, Antonio ;
Sanchez-Morillo, Daniel .
IEEE ACCESS, 2024, 12 :122805-122819
[37]   COVID-19 Detection Based on Image Regrouping and Resnet-SVM Using Chest X-Ray Images [J].
Zhou, Changjian ;
Song, Jia ;
Zhou, Sihan ;
Zhang, Zhiyao ;
Xing, Jinge .
IEEE ACCESS, 2021, 9 :81902-81912
[38]   Lung-GANs: Unsupervised Representation Learning for Lung Disease Classification Using Chest CT and X-Ray Images [J].
Yadav, Pooja ;
Menon, Neeraj ;
Ravi, Vinayakumar ;
Vishvanathan, Sowmya .
IEEE TRANSACTIONS ON ENGINEERING MANAGEMENT, 2023, 70 (08) :2774-2786
[39]   Creating a reference database of cargo inspection X-ray images using high energy radiographs of cargo mock-ups [J].
Selina Kolokytha ;
Alexander Flisch ;
Thomas Lüthi ;
Mathieu Plamondon ;
Wicher Visser ;
Adrian Schwaninger ;
Diana Hardmeier ;
Marius Costin ;
Caroline Vienne ;
Frank Sukowski ;
Ulf Hassler ;
Irène Dorion ;
Najib Gadi ;
Serge Maitrejean ;
Abraham Marciano ;
Andrea Canonica ;
Eric Rochat ;
Ger Koomen ;
Micha Slegt .
Multimedia Tools and Applications, 2018, 77 :9379-9391
[40]   Creating a reference database of cargo inspection X-ray images using high energy radiographs of cargo mock-ups [J].
Kolokytha, Selina ;
Flisch, Alexander ;
Luthi, Thomas ;
Plamondon, Mathieu ;
Visser, Wicher ;
Schwaninger, Adrian ;
Hardmeier, Diana ;
Costin, Marius ;
Vienne, Caroline ;
Sukowski, Frank ;
Hassler, Ulf ;
Dorion, Irene ;
Gadi, Najib ;
Maitrejean, Serge ;
Marciano, Abraham ;
Canonica, Andrea ;
Rochat, Eric ;
Koomen, Ger ;
Slegt, Micha .
MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (08) :9379-9391